background image

OPERATION MANUAL

ChromaFlex Chassis

www.atxnetworks.com

www.atx.com

ChromaFlex

DISCONTINUED

Summary of Contents for ChromaFlex

Page 1: ...OPERATION MANUAL ChromaFlex Chassis www atxnetworks com www atx com ChromaFlex DISCONTINUED ...

Page 2: ...r non ATX product and company names in this manual are the property of their respective companies Although every effort has been taken to ensure the accuracy of this document it may be necessary without notice to make amendments or correct omissions Specifications subject to change without notice ...

Page 3: ... 2 Plug in Application Module Menu Tree 3 4 3 3 2 1 Chromadigm Chirp Cancelled Transmitter Module CCTX CCT4 CCT2 Tree 3 5 3 3 2 2 Chromadigm Chirp Cancelled Transmitter Module CCT1 Tree 3 7 3 3 2 3 EDFA AGC EDFA VG EDFA Menu Tree 3 10 3 3 2 4 Quad Return Receiver QRRX 3 12 3 3 2 5 Optical Switch 3 14 3 3 2 5 1 Optical Switch Switching Criteria 3 15 3 3 2 6 DMTX DMT2 1310 DMT2 ITU DMT3 1310 DMT3 IT...

Page 4: ...m Command Page 5 12 5 7 1 System Command Page for Release 4 4 Older 5 12 5 7 2 System Command Page for Release 4 5 Later 5 12 5 7 3 Example for System Command Page for Release 4 4 Older 5 13 5 7 4 Example for System Command Page for Release 4 5 Later 5 14 5 8 HTTP Troubleshoot Guide 5 15 6 USER INTERFACE CROSS REFERENCE 6 1 6 1 Chassis Attributes 6 1 6 2 Plug in Module Attributes 6 1 6 2 1 Chromad...

Page 5: ...user interfaces for ChromaFlex chassis and associated plug in application modules The user interfaces include chassis and application module front panel LEDs the hand held display module s button operations and LCD display Craft Line Interfaces and remote monitoring through SNMP and Graphical User Interface CHAPTER 1 ...

Page 6: ...SCOPE 1 2 ChromaFlex Chassis Operation Manual ATX Confidential Proprietary This page intentionally left blank CHAPTER 1 ...

Page 7: ...on LED test Amber indicates the monitored function is in minor alarm condition This is also temporarily observed during power on LED test Red indicates the monitored function is in major alarm condition This is also observed temporarily during power on LED test Power up LED test At the beginning of each power up of all modules the color of all LEDs turns from Red Yellow to Green Figure 1 Generic A...

Page 8: ...ted ITU channel 1 The CCT1 detects the alarms and reflects them on the front panel LEDs based on the following schema LED Trigger Events OPT Laser temperature Output power Module temperature RF RF Example 1 The module temperature is normal but the laser temperature is at a level that indicates a major alarm The top LED associated with the interface shall be observed as red 2 3 3 EDFA AGC EDFA VG E...

Page 9: ... but switch is major The top LED associated with the slot shall be observed as red 2 3 6 DMTx DMT2 1310 DMT2 ITU DMT3 1310 DMT3 ITU DMT4 1310 DMT4 ITU The DMTx detects the alarms and reflects them on the front panel LEDs based on the following schema For DMT3 modules there are three pairs of LEDs OPT on top and RF on bottom and DMT4 modules there are four pairs of LEDs LED Trigger Events OPT Top L...

Page 10: ...LED DISPLAY 2 4 ChromaFlex Chassis Operation Manual ATX Confidential Proprietary This page intentionally left blank CHAPTER 2 ...

Page 11: ...d fan alarms module temperature reading etc during the reset process There is no operational impact to the active plug in application modules 3 1 Connecting the Display Module Connect the Display Cable to the female DB15 connector labeled I DISPLAY on the face of ChromaFlex Controller module and to the female DB15 connector on the Display Module The ChromaFlex Controller performs a quick reboot wh...

Page 12: ...button decreases the value In the Gain Setting Menu the cursor displays Gain steps 3 the Gain steps 2 shall be displayed after Left button is pressed Select There are multiple meanings to the select button Select to execute the action where the cursor is located Example 1 If the cursor is located at the Prev menu line the display shall change to the NEXT higher menu after the Select button is pres...

Page 13: ...hassis or greeting menu of the selected slot 3 3 1 Chassis System Menu Trees The ChromaFlex chassis LCD menu is structured into bi level trees The top level is system related information and the second level is plug in related information The top level contains the menu for second level but each has its own menu structure Level 1 Level 2 Level 3 Greeting Slot Status Voltage V Chassis Mod Temp Mode...

Page 14: ...isplays the hardware version information of ChromaFlex chassis SW Ver displays the software version information of ChromaFlex chassis Ser displays the serial number of ChromaFlex chassis Alarm Displays chassis related alarm status Pwr Sply displays the health of chassis power supply Mod Temp displays the health of chassis temperature Fan displays the collective health of the chassis fans Prev Menu...

Page 15: ... Mode Setting Mode Save Prev Menu Gain Setting RF Lvl rdB Gain Steps Save Prev Menu Prev Menu Tx Status Opt RF Att dB Mode Prev Menu Alarm Laser Temperature Output Pwr RF Level Unit Temp Prev Menu Status Temp C Power mW Power dBm RF Lvl dB Lambda nm Voltage V Prev Menu Chassis Temperature C Model Hardware Version Software Version Serial Number Prev Menu Prev Menu Table 2 ChromaFlex CCTX Display Me...

Page 16: ...wer in dBm to each ITU transmitter channel RF displays RF input level reading in dB to each ITU transmitter channel Attn displays the reading of reserve attenuation in dB Mode displayed the current mode AGC or MGC Alarm Menu Displays the status of each ITU channel Use left right buttons to select a particular transmitter ITU channel for per channel items Available channel numbers are 1 to 4 or hig...

Page 17: ... Menu Press Select will bring the plug in s greeting message screen back 3 3 2 2 Chromadigm Chirp Cancelled Transmitter Module CCT1 Tree There are multiple versions of CCT1 with constant output power CCT1 or with variable output power CCT1 VO or with fixed output power CCT1 FO User can use the OPTOut adjustment to manually increase decrease the output power level on the CCT1 VO Level 1 Level 2 Lev...

Page 18: ... be shown in this case it is CCT1 For CCT1 with variable output this would read CCT1 VO Greeting Message Setup Menu Mode Setting Mode use the right or left bottom to toggle the mode to AGC or MGC mode Save use the right or left bottom to toggle the NVRAM mode to Yes to save and press select to store the setting in the NV RAM NOTE Failing to do so may result in the loss of the setting after a reboo...

Page 19: ...vel reading in dB to each ITU transmitter channel Mode displayed the current mode AGC or MGC Alarm Menu Laser Temp displays the alarm status of laser temperature Output Pwr displays the alarm status of the optical output power RF Level displays the alarm status of the RF level Module Temp displays the alarm status of module temperature Status Menu Laser Tmp C displays the reading of laser temperat...

Page 20: ...OPTOut OPTOut dBm OPTOut dBm Save Prev Status OPT In dBm OPT Out dBm Gain dB Voltage V Prev Menu Alarm OPT In Pwr OPT Out Pwr Module Temp Prev Menu Chassis Tmp C Model HW Ver SW Ver Ser Prev Menu Prev Menu Table 4 ChromaFlex AGC EDFA Display Menu Overview Greeting After a valid slot is selected from the option menu of Chassis a greeting menu of the selected module will be shown in this case it is ...

Page 21: ... adjustment of output power level Use the right or left to toggle through available options Save use the right or left bottom to toggle the NVRAM mode to Yes to save and press select to store the setting in the NV RAM NOTE Failing to do so may result in the loss of the setting after a reboot power cycle Status Menu OPT Input dBm displays the reading of optical input power in dBm OPT Output dBm dis...

Page 22: ...er Prev Menu Prev Menu Table 5 ChromaFlex QRRX Display Menu Overview Greeting After a valid slot is selected from the option menu of Chassis a greeting menu of the selected module will be shown in this case it is QRRX Greeting Message Press Select button to go into the plug in menu Setup Menu Mode Setting Sel Ch use the right or left bottom to select the channel receiver number 1 to 4 to modify Mo...

Page 23: ... a channel valid channel numbers are 1 to 4 Pwr dBm displays the reading of optical input power in dBm Attn dB displays the reading of attenuation in dB Voltage V displayed the on board supply voltage Alarm Menu Rcvr Pwr displays the alarm status of each receiver optical input Use left right buttons for channel selection available channel numbers are 1 to 4 Module Temp displays the alarm status of...

Page 24: ...valid slot is selected from the option menu of Chassis a greeting menu of the selected module will be shown in this case it is Optical Switch Greeting Message Press Select button to go into the plug in menu Prev Menu Press Select will bring back to the System menu The entries in plug in menu are described as follows Setup Menu Mode Select the optical switch mode the selections are Auto Manual_Pri ...

Page 25: ... optical switch position either Primary or Secondary Alarm Menu OPin Pwr displays the alarm state of optical input power status Press Right or Left button to cycle through available channels Switch displays the alarm status of optical switch The alarm is determined based on following conditions Severity Condition Major Optical switch is faulty Secondary input is invalid when primary input is below...

Page 26: ...T4 ITU The modules covered under DMTX includes DMT3 1310 DMT3 ITU DMT4 1310 DMT4 ITU Level 1 Level 2 Level 3 Level 4 InnoTrans DMTX Setup Mode Setting Sel_Ch Mode Save Prev Menu Tx Gain Setting Sel_Ch RF Lvl rdB Gain Steps Save Prev Menu Tx Fiber Length for ITU version only Sel_Ch Length km Save Prev Menu Prev Menu Status Laser Pwr dBm RF Lvl dB Tx Attn dB Laser Temp C Lambda nm Prev Menu Alarm La...

Page 27: ...of the setting after a reboot power cycle Tx Fiber Length This option is for ITU version only Sel_Ch use the right or left bottom to select the channel number 1 to 4 for DMT4 or 1 to 3 for DMT3 to modify Length use the right or left bottom to step up or down the length The factory default setting for this field is 10 km with adjustable range of 0 50km at 1 km increment Save use the right or left b...

Page 28: ...h in nanometer Chassis Menu Temp C displays the module s temperature reading in Centigrade Model displays the model name of plug in module HW Ver displays the hardware version information of plug in module SW Ver displays the software version information of plug in module Ser displays the serial number of plug in module Prev Menu Press Select will bring the plug in s greeting message screen back C...

Page 29: ...The remote CLI session is de activated with the command logout on CLI prompt When finishing with a remote CLI session the user shall logout instead of timeout Otherwise the remote CLI session may be still considered active Default Remote CLI login credential Must be in lowercase Login inno Password inno1 Please see footnote for important user credential support in release 4 3 and later 4 1 Command...

Page 30: ...ease 4 3 or later Only admin user has the privilege to add delete users Factory ships a default admin user with username admin and password admin Due to security concerns the administrative user management functions including add user accounts delete user accounts change user s passwords and reset to factory defaults are only available via CLI sessions Userpassword operation username permission Th...

Page 31: ...t 1 uptime 820 seconds 0 days 0 hours 13 min 40 sec info displays the chassis system and selected plug in module information Example 1 The first part is Controller module information and followed by the factory information of plug in in slot 7 ChromaFlex slot 7 info System SwVer 1 0 1 0 HwVer 1 1 ModelName CF CTRL SerialNum 24521210 Slot 7 CCTX SwVer 1 0 1 0 HwVer 1 1 ModelName CFLX CCT4 SerialNum...

Page 32: ...larm displays the alarm status of the chassis and the selected slot plug in module Example 1 ChromaFlex slot 7 alarm System PowerAlarm Normal FanAlarm Normal Slot 7 CCTX LaserTempAlarm 1 MajorLoLo 2 MajorLoLo 3 MajorLoLo 4 MajorLoLo LaserPowerAlarm 1 MajorLoLo 2 MajorLoLo 3 MajorLoLo 4 MajorLoLo LaserRfAlarm 1 MajorLoLo 2 MajorLoLo 3 MajorLoLo 4 MajorLoLo ModuleTempAlarm MinorLo DownloadStatus dis...

Page 33: ...present ChromaFlex slot 1 ModuleSupport CCTX EDFA AGC EDFA DUAL EDFA DUAL AGC EDFA ModelName displays all the model name information which can be supported by ChromaFlex Chassis Systems SerialNum displays the serial number information of the chassis controller module Network displays or set the chassis controller module network configuration Example 1 In this example the controller module contains...

Page 34: ...tname Example 1 In this example the user requested to configure the hostname InnoTrans And the controller module indicates the command execution as Successful ChromaFlex slot 1 hostname InnoTrans Successful Community displays or configures the SNMP community string Up to 3 community strings are supported The system default community string is public with read only permission Example 1 In this exam...

Page 35: ...not guarantee the attribute has been successfully altered You should retrieve the reading from module to confirm the value i e issue the status command etc 4 1 3 Common Plug in Module Information The common plug in module information is displayed when a user requests status or alarm on any slot number Status System ModuleTemp displays the chassis temperature reading in Centigrade Slot ID module na...

Page 36: ...slot 2 results in no module information being available ChromaFlex slot 1 slot 2 Slot 2 Empty selected ModuleTemp displays the module temperature reading in Centigrade Example 1 In this example the module in slot 1 reports its module temperature reading as 21 4 Centigrade ChromaFlex slot 1 ModuleTemp 21 4 deg C LaserTemp displays the laser temperature reading in Centigrade Example 1 In this exampl...

Page 37: ...ain offset setting ChromaFlex slot 1 gainoffset 1 0 steps Modification this command supports modification Example 1 In this example the interface 1 of the slot 7 module s GainOffset is configured with offset 2 ChromaFlex slot 7 GainOffset 1 modify 2 Request sent ChromaFlex slot 7 GainOffset 1 2 steps NOTE The response of a modification request may either be Request sent or Successful in either cas...

Page 38: ...ower Example 1 In this example the module in slot 1 reports the alarm status of laser power as MajorLoLo e g Major alarm with reading below the low low threshold on channel 1 ChromaFlex slot 1 LaserPowerAlarm 1 MajorLoLo LaserRfAlarm displays the alarm status of laser RF Example 1 In this example the module in slot 1 reports the alarm status of laser RF as MajorLoLo e g Major alarm with reading be...

Page 39: ... 1 reports its optical output power reading ChromaFlex slot 1 OPoutPower 1 0 0 dBm Modification this command supports modification on CCT1 VO Example 1 In this example the interface 1 of the slot 7 module s OPoutPower is configured with 9 dBm ChromaFlex slot 7 OPoutPower 1 modify 9 Successful ChromaFlex slot 7 OPoutPower 1 9 dBm GainOffset displays the gain offset setting in steps Example 1 In thi...

Page 40: ... may either be Request sent or Successful in either case the user shall retrieve the value to confirm the new value You may need to wait for a few seconds or retrieve a couple times to acquire the new value Attenuation displays the attenuation reading in dB Example 1 In this example the module in slot 1 reports its attenuation reading ChromaFlex slot 1 attenuation 1 0 0 dBm LaserTempAlarm displays...

Page 41: ...ts its optical input power reading ChromaFlex slot 1 OPinPower 1 0 0 dBm OPoutPower displays the optical output power reading in dBm Example 1 In this example the module in slot 1 reports its optical output power reading ChromaFlex slot 1 OPoutPower 1 0 0 dBm Gain displays the gain reading in dB for an AGC type EDFA This is configurable for EDFA with AGC Example 1 In this example the module in slo...

Page 42: ...lays the module temperature reading in Centigrade Example 1 In this example the module in slot 1 reports its module temperature reading as 21 4 Centigrade ChromaFlex slot 1 ModuleTemp 21 4 deg C OpticalPowerdBm displays the optical input power reading in dBm Example 1 In this example the module in slot 1 reports its optical input power reading on channel 1 ChromaFlex slot 1 OpticalPowerdBm 1 0 0 d...

Page 43: ...be Request sent or Successful in either case the user shall retrieve the value to confirm the new value You may need to wait for a few seconds or retrieve a couple times to acquire the new value OpticalPowerAlarm displays the alarm status of the optical input power Example 1 In this example the module in slot 1 reports the alarm status of the optical input power as MajorLoLo e g Major alarm with p...

Page 44: ...ld setting Example 1 In this example the module in slot 1 reports its optical switch threshold as 0 dBm ChromaFlex slot 1 thresholddBm 0 0 OPinPowerAlarm displays the alarm status of optical input power Example 1 In this example the module in slot 1 reports the alarm status of optical input 1 power as MajorLoLo e g Major alarm with power reading below the low low threshold ChromaFlex slot 1 OPinPo...

Page 45: ...LaserPowerDbm displays the laser power reading in dBm Example 1 In this example the module in slot 1 reports its laser power reading on Laser 1 ChromaFlex slot 1 LaserPowerDbm 1 0 0 dBm LaserRf displays the RF reading in dB Example 1 In this example the module in slot 1 reports its RF reading on channel 1 ChromaFlex slot 1 LaserRf 1 0 0 dB Wavelength displays the laser wavelength in nanometer Exam...

Page 46: ...ample 1 In this example the module in slot 1 reports its gain control mode ChromaFlex slot 1 gaincontrol MGC Modification this command supports modification Example 1 In this example the interface 1 of the slot 7 module s GainControl is configured with MGC mode ChromaFlex slot 7 GainControl 1 modify MGC Successful ChromaFlex slot 7 GainControl 1 MGC NOTE The response of a modification request may ...

Page 47: ...o e g Major alarm with reading below the low low threshold on channel 1 ChromaFlex slot 1 LaserTempAlarm 1 MajorLoLo LaserPowerAlarm displays the alarm status of laser power front panel displayed as output power Example 1 In this example the module in slot 1 reports the alarm status of laser power as MajorLoLo e g Major alarm with reading below the low low threshold on channel 1 ChromaFlex slot 1 ...

Page 48: ...CRAFT LINE INTERFACE CLI 4 20 ChromaFlex Chassis Operation Manual ATX Confidential Proprietary This page intentionally left blank CHAPTER 4 ...

Page 49: ...wser URL The target ip address must be the IP address of the chassis for observation and reachable from the host browser 5 1 System Login Page This is the system login page where credentials are collected for accessing the system Username your username Password your password Where the your username and your password are configured by your system administrator The chassis is shipped with a set of f...

Page 50: ... controller module Note the chassis is shipped with default network settings The 1st step is to use the chassis controller s front panel serial port to configure the IP information for your network before launching the GUI application The text that is in bold font on the header banner indicates the current page being displayed In this example Home is bold and a larger font as compared to the other...

Page 51: ...ottom half of the status page under the Slots banner shows the status of the eight available chassis slots The slot status informs if the slot is empty or displays the module type that is installed and the options available for the populated slots such as View and Provision Click on View for details of an individual modules status Click on Provision to access an individual modules configuration co...

Page 52: ...formation The controller module serial number is also displayed on the banner The chassis parameter either will state Normal or flagged with a yellow 5 4 2 Alarm Slots Banner The bottom portion of this page under the Slots banner shows the status of the eight available chassis slots If a module has an alarm condition the slot number will be highlighted in amber Clicking on View will open the modul...

Page 53: ...he page 1 Chassis Model shows the selected chassis controller module serial number 2 Slot displays the module type populated in the 4 Status 5 Alarm 5 5 1 Factory Information Banner The Factory Information banner displays the selected modules Software Version Hardware Version Model Name and Serial Number 5 5 2 Status Banner The Status Banner displays the current values of the selected modules para...

Page 54: ...ntroller module serial number 2 Slot displays the module type populated in the selected slot 3 Factory Information 4 Provision 5 Response The top part of the page displays the chassis information slot information and module factory information Below will describe the Provision and Response banner interface 5 6 1 Provision for Release 4 4 Older The Provision section allows a user to enter a modific...

Page 55: ...ck from the target chassis module Figure 5 3 Example of Provision Response 5 6 3 Provision for Release 4 5 Later The Provision section allows a user to configure the value for settable attributes For the attributes with settable range user may either use the slider or text box to set the desired value For the attributes with selections user may use the radio box to set the desired selection CHAPTE...

Page 56: ... button to issue the command At any time you may click on the Readback button to retrieve information This would be helpful to display the current setting prior to submitting a new setting The information and response is displayed in the Response Box Figure 5 4 Provision Page with Slider Text Box 5 6 4 Response The Response section displays the information returned back from the target chassis mod...

Page 57: ...in slot 5 1 From the Chassis Status page go to Slot 5 Destacker Proxy and click on the Provision link This will take you to the modules Provision Page 2 In the Provision Page click on the Readback button of Attenuation Channel 4 3 Observe the value returned in Response Box under the Response banner For example The following text in the Response Box indicates a the timestampe of response reception ...

Page 58: ...n the Response Box as the new value being confirmed Figure 5 8 Example of Readback Confirmation 5 6 6 Configuring a CCT4 Gain Control Example based on release 4 4 older Modify Example to modify the GainControl of interface 1 of a CCT4 module in slot 7 from MGC to AGC 1 From the Chassis Status page go to Slot 7 CCT4 and click on the Provision link This will take you to the modules Provision Page CH...

Page 59: ...eceived on Wed Oct 29 00 45 05 2014 for command GainControl and the returned value is MGC Wed Oct 29 00 45 05 2014 GainControl AGC 4 Type in the text box associated with GainControl 1 modify MGC 5 Click on the Submit button 6 Observe the response displayed in the Response Box Either Request sent or Successful is considered that the command has been issued correctly 7 Wait for a couple seconds and ...

Page 60: ...he command syntax is given below each command Figure 5 9 System Command Page for Release 4 4 Older 5 7 2 System Command Page for Release 4 5 Later Similar to the module s Provision Page the System Command Page is also presented as either radio box text box or combination of both User can see the help context by hovering the mouse over the question mark of the command Figure 5 10 System Command Pag...

Page 61: ...d link in the Header 2 In the System Command Page click on the sysLocation Readback button 3 Observe the value returned in the Response Box under the response banner For example The following text in the Response Box indicates a the timestampe of response reception for command Attenuation and the returned value is 16 0 dB 4 Type in the text box associated with sysLocationt Irvine CA 5 Click on the...

Page 62: ...dback botton to confirm the new value 1 Go to the System Command Page by clicking on the System Command link in the Header 2 In the System Command Page click on the Community Readback button 3 Observe the value returned in the Response Box under the response banner 4 Check the radio button add 5 Type in the text box associated with sysLocationt InnoTran rw 6 Click on the Submit botton 7 Observe th...

Page 63: ...ymptom Unable to login login credential being rejected browser complains the password length problem Solution Log out and close all HTTP sessions on the computer Open the browser again Clean up the browser cache saved password cookies Log in with username your username password your password then click on Submit Do not allow browser to remember password Wait for a couple of minutes for credential ...

Page 64: ...ns logging into a target server and the server receives simultaneous requests The server guarantees each request is being processed in its entirety before accepting a second request it blocks the later request until the first one is complete This can be solved by several solutions Log out and close the other active HTTP sessions Or wait for the 1st request to complete page will be reloaded automat...

Page 65: ...vides an inventory snapshot while the user can extract the slot state and inventory via SNMP 6 2 Plug in Module Attributes 6 2 1 Chromadigm Chirp Cancelled Transmitter Module CCT4 CCT2 Attributes Front Panel Display CLI SNMP OID SNMP Trap ID Setup Mode Setting Mode GainControl innoTransCFlexModuleAnalogTable 8 Setup Tx Gain Settings Gain steps GainOffset innoTransCFlexModuleAnalogEntry 7 Chassis M...

Page 66: ... 3 EDFA AGC EDFA VG EDFA Attributes Front Panel Display CLI SNMP OID SNMP Trap ID Status Module Temperature C ModuleTemp innoTransChromaFlexModuleEntry 6 Status Optical Input dBm OPinPower innoTransCFlexModuleAnalogTable 11 Status Optical Output dBm OPoutPower innoTransCFlexModuleAnalogTable 12 Status Gain dB Gain innoTransCFlexModuleAnalogTable 24 Alarm Optical Input OPinPowerAlarm iTChromaFlexNo...

Page 67: ...Setting Mode GainControl innoTransCFlexModuleAnalogTable 8 Setup Tx Gain Settings Gain steps GainOffset innoTransCFlexModuleAnalogEntry 7 Setup Tx Fiber Length Length km only on ITU modules FiberLength innoTransCFlexModuleAnalogTable 25 Chassis Module Temperature C ModuleTemp innoTransChromaFlexModuleEntry 6 Status Laser Temperature C LaserTemp innoTransCFlexModuleAnalogTable 3 Status Laser Pwr dB...

Page 68: ...USER INTERFACE CROSS REFERENCE 6 4 ChromaFlex Chassis Operation Manual ATX Confidential Proprietary This page intentionally left blank CHAPTER 6 ...

Page 69: ...ONVENTION FROM SNMPv2 TC InetAddress InetAddressType FROM INET ADDRESS MIB HeTenthdBm HeTenthCentigrade HeTenthdB HeTenthVolt HeTenthdBmV FROM SCTE HMS HEADENDIDENT MIB innoTransCFlex MODULE IDENTITY LAST UPDATED 201505080000Z May 08 2015 ORGANIZATION InnoTrans Communications CONTACT INFO InnoTrans SNMP Group mailto snmp inno trans com DESCRIPTION InnoTrans enterprise attributes REVISION 201505080...

Page 70: ...nal errors such as time out Values DisplayString NA Unsigned32 999 Integer32 999 HeTenthCentigrade 999 HeTenthdBm 999 HeTenthdBmV 999 HeTenthdB 999 HeTenthVolt 999 System Attributes innoTransCFlexSwVer OBJECT TYPE SYNTAX DisplayString MAX ACCESS read only STATUS current DESCRIPTION The software version s innoTransCFlexSystem 1 innoTransCFlexModel OBJECT TYPE SYNTAX DisplayString MAX ACCESS read on...

Page 71: ...US current DESCRIPTION The address to which traps shall be sent Syntax ip address of trap destination innoTransCFlexSystem 6 innoTransCFlexTrapTarget2 OBJECT TYPE SYNTAX InetAddress MAX ACCESS read write STATUS current DESCRIPTION Secondary address to which traps shall be sent This is to support a secondary EMS NMS Syntax ip address of trap destination innoTransCFlexSystem 7 innoTransCFlexDownload...

Page 72: ...innoTransCFlexSystem 10 innoTransCFlexHwVer OBJECT TYPE SYNTAX DisplayString MAX ACCESS read only STATUS current DESCRIPTION The Hardware Version includes versions for microprocessor and microcontroller innoTransCFlexSystem 11 innoTransCFlexTemp OBJECT TYPE SYNTAX HeTenthCentigrade MAX ACCESS read only STATUS current DESCRIPTION The system temperature innoTransCFlexSystem 12 Equipment Attributes i...

Page 73: ...nnoTransCFlexModuleIndex OBJECT TYPE SYNTAX Integer32 1 8 MAX ACCESS not accessible STATUS current DESCRIPTION The module index The index of the first module is 1 innoTransCFlexModuleEntry 1 innoTransCFlexSlotState OBJECT TYPE SYNTAX INTEGER equipped 1 unequipped 2 MAX ACCESS read only STATUS current DESCRIPTION This object indicates the state of a slot When a module is plugged in a slot it become...

Page 74: ... STATUS current DESCRIPTION The hardware version s of the module innoTransCFlexModuleEntry 7 innoTransCFlexModuleDisplayName OBJECT TYPE SYNTAX DisplayString MAX ACCESS read only STATUS current DESCRIPTION The slot module display name in more user friendly format For module spans multiple slots this attribute shows the same display name on all occupied slots innoTransCFlexModuleEntry 8 Module Lase...

Page 75: ...yString itModuleAmpPumpPower HeTenthdB itModuleAmpOutputPower HeTenthdB itModuleOPinPower HeTenthdBm itModuleOPoutPower HeTenthdBm itModuleLaserBiasCurrent Integer32 itModuleRFPower HeTenthdBmV itModuleOpticalPowerdBm HeTenthdBm itModule3V3Power HeTenthVolt itModuleOpticalModulationIndex Integer32 itModuleGainReserve HeTenthdB itModuleAttenuation HeTenthdB itModuleSwitch DisplayString itModuleMode...

Page 76: ...lliWatt innoTransCFlexModuleAnalogEntry 4 itModuleLaserPowerdBm OBJECT TYPE SYNTAX HeTenthdBm MAX ACCESS read only STATUS current DESCRIPTION Laser power in tenth of dBm innoTransCFlexModuleAnalogEntry 5 itModuleLaserWavelength OBJECT TYPE SYNTAX DisplayString MAX ACCESS read only STATUS current DESCRIPTION Laser wavelength innoTransCFlexModuleAnalogEntry 6 itModuleLaserGainOffset OBJECT TYPE SYNT...

Page 77: ...r output power in tenth of dBm innoTransCFlexModuleAnalogEntry 10 itModuleOPinPower OBJECT TYPE SYNTAX HeTenthdBm MAX ACCESS read only STATUS current DESCRIPTION Optical input power in tenth of dBm innoTransCFlexModuleAnalogEntry 11 itModuleOPoutPower OBJECT TYPE SYNTAX HeTenthdBm MAX ACCESS read write STATUS current DESCRIPTION Optical output power in tenth of dBm innoTransCFlexModuleAnalogEntry ...

Page 78: ...ex OBJECT TYPE SYNTAX Integer32 MAX ACCESS read only STATUS current DESCRIPTION Optical modulation index innoTransCFlexModuleAnalogEntry 17 itModuleGainReserve OBJECT TYPE SYNTAX HeTenthdB MAX ACCESS read only STATUS current DESCRIPTION Gain reserve in tenth of dB innoTransCFlexModuleAnalogEntry 18 itModuleAttenuation OBJECT TYPE SYNTAX HeTenthdB MAX ACCESS read write STATUS current DESCRIPTION At...

Page 79: ...mV OBJECT TYPE SYNTAX HeTenthdBmV MAX ACCESS read only STATUS current DESCRIPTION Threshold in tenth of dBmV innoTransCFlexModuleAnalogEntry 23 itModuleGaindB OBJECT TYPE SYNTAX HeTenthdB MAX ACCESS read only STATUS current DESCRIPTION Gain in tenth of dB innoTransCFlexModuleAnalogEntry 24 itModuleFiberLength OBJECT TYPE SYNTAX DisplayString MAX ACCESS read only STATUS current DESCRIPTION Fiber le...

Page 80: ...ectIndex OBJECT TYPE SYNTAX Integer32 MAX ACCESS accessible for notify STATUS current DESCRIPTION The integer object reports the interface index number from 1 to 4 iTCFlexNotificationObjects 1 notifyObjectValue OBJECT TYPE SYNTAX DisplayString MAX ACCESS accessible for notify STATUS current DESCRIPTION The value of the notification object iTCFlexNotificationObjects 2 HeCommonLogState TEXTUAL CONVE...

Page 81: ...ifSystemTemp NOTIFICATION TYPE OBJECTS notifyObjectIndex notifyObjectValue notifyAlarmState notifyModuleIndex STATUS current DESCRIPTION The notification of system temperature alarm iTCFlexNotification 30 notifPower NOTIFICATION TYPE OBJECTS notifyObjectIndex notifyObjectValue notifyAlarmState STATUS current DESCRIPTION The notification of system power alarm iTCFlexNotification 31 notifFan NOTIFIC...

Page 82: ...otifyObjectValue notifyAlarmState notifyModuleIndex STATUS current DESCRIPTION The notification of laser RF alarm There are 4 lasers in the system The notifyObjectIndex is used to identify which one The notifyAlarmState indicates the alarm state iTCFlexNotification 12 notifPumpPower NOTIFICATION TYPE OBJECTS notifyObjectIndex notifyObjectValue notifyAlarmState notifyModuleIndex STATUS current DESC...

Page 83: ...fication 16 notifShutoff NOTIFICATION TYPE OBJECTS notifyObjectIndex notifyObjectValue notifyAlarmState notifyModuleIndex STATUS current DESCRIPTION The notification of pump shutoff alarm iTCFlexNotification 17 notifGain NOTIFICATION TYPE OBJECTS notifyObjectIndex notifyObjectValue notifyAlarmState notifyModuleIndex STATUS current DESCRIPTION The notification of gain related alarm iTCFlexNotificat...

Page 84: ...yObjectValue notifyAlarmState notifyModuleIndex STATUS current DESCRIPTION The notification of SFP status alarm iTCFlexNotification 23 30 and above are system notifications Conformance Information innoTransCFlexMibConformance OBJECT IDENTIFIER innoTransCFlex 4 innoTransCFlexMibGroups OBJECT IDENTIFIER innoTransCFlexMibConformance 1 innoTransCFlexMibCompliances OBJECT IDENTIFIER innoTransCFlexMibCo...

Page 85: ...nnoTransCFlexReboot innoTransCFlexHwVer innoTransCFlexTemp STATUS current DESCRIPTION This group consists of objects in InnoTrans ChromaFlex system group innoTransCFlexMibGroups 1 innoTransCFlexNotificationObjectGroup OBJECT GROUP OBJECTS notifyObjectIndex notifyObjectValue notifyAlarmState notifyModuleIndex STATUS current DESCRIPTION This group consists of objects in InnoTransce ChromaFlex notifi...

Page 86: ...duleSerial innoTransCFlexModuleTemp innoTransCFlexModuleHwVer innoTransCFlexModuleDisplayName STATUS current DESCRIPTION This group consists of objects in InnoTrans ChromaFlex module group innoTransCFlexMibGroups 5 innoTransCFlexModuleLaserGroup OBJECT GROUP OBJECTS itModuleLaserRFdB itModuleLaserTemp itModuleLaserPowerWt itModuleLaserPowerdBm itModuleLaserWavelength itModuleLaserGainOffset itModu...

Page 87: ...l Proprietary itModuleMode itModuleThresholddBm itModuleThresholddBmV itModuleGaindB itModuleFiberLength itModuleChannelMode itModuleGainSet STATUS current DESCRIPTION This group consists of objects in InnoTrans ChromaFlex module interface group innoTransCFlexMibGroups 6 END CHAPTER 7 ...

Page 88: ...SNMP ENTERPRISE ATTRIBUTES 7 20 ChromaFlex Chassis Operation Manual ATX Confidential Proprietary This page intentionally left blank CHAPTER 7 ...

Page 89: ...Free 866 YOUR ATX 866 968 7289 USA Canada only Email support atx com SALES ASSISTANCE Tel 289 204 7800 press 2 Toll Free 866 YOUR ATX 866 968 7289 USA Canada only Email insidesales atx com FOR HELP WITH AN EXISTING ORDER Tel 289 204 7800 press 3 Toll Free 866 YOUR ATX 866 968 7289 USA Canada only Email orders atx com Web www atx com 8 2 Warranty Information All of ATX Networks products have a 1 ye...

Page 90: ...Toll Free 866 YOUR ATX 866 968 7289 support atx com 2020 by ATX Networks Corp and its affiliates collectively ATX Networks Corp All rights reserved This material may not be published broadcast rewritten or redistributed Information in this document is subject to change without notice ...

Reviews: