background image

Auber Instruments, Inc. 

 

www.auberins.com 

JSL-64A-EST Application Guide 

Version 1.0 (April 2020) 

 
 

Introduction 

In this document, we will show you the idea of how to use the JSL-64A-EST timer as an espresso-shot-timer on 
your home espresso machine. This application guide is based on a home espresso machine that requires 120VAC 
power and is installed with a vibration pump also requires 120VAC. If you have an espresso machine and a 
vibration pump that require 240VAC, you’ll need to use a relay with 240V coil voltage.  
 
 

Parts  

JSL-64A-EST timer 
R30A relay (120VAC coil voltage, and one pair of normally open relay contacts) 
Wires, 6 pieces 
 
 

Wiring

 

Connect the timer, R30A relay, and the vibration pump as shown in the Figure 1 below. Please note that the red 
lines and black lines indicate wires that carry 120VAC, while the blue lines indicates the wires only carry low 
voltage signal. Wires attached to pin 1 and 2 on the JSL-64A supply 120V power to the timer. Tap these two wires 
to the power button of your espresso machine.  
 

Pump

Mimi Relay

R30A

COM

NC

NO

Original 

wires on the 

pump 

(120VAC)

COM

6

7

8

9

10

1

2

3

4

5

ST

To 120 VAC

A1

A2

JSL-64A Timer

 

Figure 1. Connecting JSL-64A, relay, and the vibration pump together.  

 
 

Timer Setting 

To use this timer as an espresso shot timer, please set the timer function 

FUNC

 = 

EST

, and the timer unit 

T1u

 = 

S

Then press the RST key to clear the screen. The display will show “0.00” as shown in the Figure 2 below. Please 
refer to the manual of JSL-64A for details on how access the parameters.  
 
 

Reviews: