background image

PRE-INSTALLATION  NOTES:

PASSIVE / ACTIVE ARMING SELECTION:

This alarm can be programmed to operate as either a “PASSIVE” or “ACTIVE” arming security system.
As a “Passive” alarm, the system will automatically arm itself approximately 30 seconds after the ignition key is turned
off, one door is opened, then all vehicle doors are closed,  (arming is suspended until the last door is closed). This
feature protects the vehicle in the event you forget to arm the system using the keychain transmitter.
This system is shipped in the passive mode, therefore no modifications are required to make the system operate
as a “Passive” alarm.
As an “Active” alarm, the system can only be armed using the keychain transmitter. There will be no backup
automatic arming.
Caution: Be certain the module is disconnected from the main wiring harness before attempting to cut the wire

loops.  This will prevent shorting of the control module and any damage to the vehicle.
To make the system operate as an “Active” alarm, open the access door located in the module's case,
and cut the small Black Loop Wire.

VOLTAGE SENSE / HARDWIRE SELECTION:

This alarm can be wired to operate as a Voltage Sensing or a Hardwire system.
As a voltage sensing system, the alarm will trigger any time an entry point that illuminates a courtesy light is opened.
The system is shipped in the voltage sensing mode, therefore, no modifications are required to make this system
a voltage sensing alarm.
As a hardwire system, the alarm will trigger any time a door, hood, trunk, etc. is opened, by wiring directly to the
switches. This means that if the courtesy light is burned out, or the courtesy light fuse is blown, the alarm will continue
to protect all points of entry.
Caution: Be certain the module is disconnected from the main wiring harness before attempting to cut the wire

loops.  This will prevent shorting of the control module and any damage to the vehicle.
To make this system operate as a hardwire alarm, open the access door located in the module's case,
and cut the small Green Loop Wire.

NOTE:  When “Passive Arming” and “Voltage Sensing” are selected, you must hardwire the driver’s door pin switch

or passive arming will not be initiated.

STARTER DISABLE:

This system provides an output to control an optional starter cut relay (not included).
When this option is installed, any time the system is armed, the vehicles starting circuit is inoperable.

CHANNEL 2 OUTPUT:

This system provides an additional hardwire remote output to control an assortment of optional upgrades.
This output is an independent channel from the transmitter and is controlled by button #2 on the transmitter.  It is
a delayed ground pulse (300 mA maximum), and can be used to control:

l

Optional trunk release relay AS-9256

l

Optional remote starter AS-9075

l

Optional window roll up AS-9153

CHANNEL 3 : (TRANSMITTER ONLY)

The transmitters included in this alarm incorporate an additional independent 3rd radio channel.  Although the alarm
module will only respond to 2 channels, the 3rd radio channel can be programmed to an option garage door interface
(AS-9154).  The AS-9154 has its own on-board programmable receiver and is designed to operate with most existing
automatic garage door openers.

Model  APS-15KB

REMOTE CONTROL

AUTO SECURITY SYSTEM

Installation Manual

Summary of Contents for Prestige APS-15KB

Page 1: ...irectly to the switches This means that if the courtesy light is burned out or the courtesy light fuse is blown the alarm will continue to protect all points of entry Caution Be certain the module is disconnected from the main wiring harness before attempting to cut the wire loops This will prevent shorting of the control module and any damage to the vehicle To make this system operate as a hardwi...

Page 2: ...ted to a grounded metal surface of the vehicle It is important to select a location where water cannot flow or collect and to avoid all drip gutters on hood and trunk fender walls Choose locations that are protected by rubber gaskets when the hood or trunk lid is closed The pin switch can be mounted using the bracket provided or direct mounted by drilling a diameter mounting hole Keep in mind that...

Page 3: ...t the green wire loop from the alarm control module Connect the red fused wire to a 12 VDC constant battery source DARK BLUE WIRE 300 mA PULSED OUTPUT CHANNEL 2 The dark blue wire pulses to ground via an independent RF channel from the keychain transmitter This is a transistorized low current output and should only be used to drive an external relay coil WARNING Connecting the dark blue wire to th...

Page 4: ...R LOCK OUTPUTS These wires will provide either a pulsed ground output to the factory door lock control relay or a pulsed 12 volt output to the factory door lock control relay In either case the maximum current draw through these outputs must not exceed 300 mA 3 Wire Ground Switched Door Locks In this application the red wire provides a ground pulse during arming pulsed ground lock output Connect t...

Page 5: ...the side of a closed fist considering the amount of force required to break a window CAUTION Never perform this test on the vehicle s glass as you may break the window Turn the adjustment screw clockwise increasing sensitivity about turn and re test Repeat this procedure until the alarm sounds when the bumper is struck WARNING Setting the sensitivity too high can cause false alarms due to noise vi...

Page 6: ... 2000 Audiovox Corporation Hauppauge NY 11788 128 5745A ...