USING THIS INSTRUCTION LEAFLET 

This instruction leaflet has been designed as a general installation guide to help you install your particular outdoor 
luminaire. Please pay particular attention to how your luminaire is wired. If you require any guidance or any further 
information regarding your outdoor luminaire, please contact us via the details below or visit our web site. 

IMPORTANT INSTALLATION INFORMATION 

 

Installation should be carried out in accordance with the latest edition of the I.E.E. Wiring Regulations (BS7671) 

and taking into consideration the latest Building Regulations. If in doubt, consult a qualified electrician. 

 

Before commencing any installation or maintenance work, ensure electricity is switched off at the mains. 

 

Please take note of the maximum rated voltage for your luminaire. 

 

Please take note of the IP (Ingress Protection) rating of your luminaire when deciding location. 

 

Always allow sufficient slack in the supply cable in order to remove the luminaire from its position for any future 

maintenance. 

 

Please take note of the maximum lamp wattage for your luminaire as detailed on the product label.  

 

Ensure that ALL electrical connections are tight with no loose strands, including factory made connections. 

 

Care must be taken for installations where the lens or bezel may come into contact with bare skin. 

 

All luminaries run HOT. It is the installer’s responsibility to consider fire & safety risk and take appropriate 

precautions. 

 

Please take note of the nearest illuminated surface as detailed on the product label. 

 

LABEL SYMBOLS EXAMPLES 

 

          Luminaire can be mounted on a normally flammable surface e.g. a material based on wood. 

 

          Luminaire can not be mounted on normally flammable surfaces. 

 

          Double insulated – does not require an earth connection. 

 

          Luminaire must be earthed. 

 

          Complies with Class 3 – SELV (Safety Extra Low Voltage) less than 50VAC. 

 

          Nearest illuminated surface in front of the luminaire. 

 

          Indicates a non-replaceable LED (Light Emitting Diode) lamp. 

 

          IP44 - Protected against splashing water. 

 

          IP65 – Protected against low pressure jets of water. 

 

          IP68 – Protected against submersion in water. 

IMPORTANT USER INFORMATION 

 

Always switch off mains supply before installation, servicing, fitting or changing the lamp. 

 

Replace failed lamps immediately. Allow the lamp and fitting to cool before replacing lamp. Check that the correct 

lamp type and wattage is fitted. Dispose of failed lamps correctly. 

 

Replace any cracked protective glass immediately and use only original parts to do this. 

 

It is recommended to clean every two to three months to preserve the finish of this product. Do not use solvents 

or aggressive cleaning agents. 

 

Summary of Contents for LINEAR FLUORESCENT WALKOVER LUMINAIRE

Page 1: ...duct label Ensure that ALL electrical connections are tight with no loose strands including factory made connections Care must be taken for installations where the lens or bezel may come into contact with bare skin All luminaries run HOT It is the installer s responsibility to consider fire safety risk and take appropriate precautions Please take note of the nearest illuminated surface as detailed...

Page 2: ...tall your luminaire in a dip in the ground or in an area of localised flooding This is to avoid pooling of water over the top of the glass see Fig 2 3 When installing the mounting sleeve of the luminaire into the ground always prepare a minimum of 30cm of gravel under the sleeve housing to allow for drainage Check that drainage is adequate by filling the hole with water and confirming that the wat...

Page 3: ... 4 Protection against water sprayed from all direction limited ingress permitted 5 Protected against dust limited ingress e g no harmful deposits 5 Protection against low pressure jets of water from all direction limited ingress permitted 6 Totally protected against dust 6 Protection against high pressure jets of water from all direction limited ingress permitted 7 Protection against the effects o...

Page 4: ...keback of the product for the correct disposal GUARANTEE This product is guaranteed in the UK for a period of 1 year from the date of purchase unless otherwise stated in current company literature The guarantee is invalid in the case of improper use installation tampering removal of the Q C date label installation in an improper working environment or installation not according to the current edit...

Reviews: