background image

OPERATING MANUAL

Summary of Contents for Controur

Page 1: ...OPERATING MANUAL ...

Page 2: ...version 802 1 ...

Page 3: ...3 General information 4 Engine locking 5 Locking algorithm 5 Locking procedure 5 Wiring scheme 6 Connection between IGLA and CONTOUR 8 Siren 9 Specifications 10 Contents of the set 10 TABLE OF CONTENTS ...

Page 4: ...s of open hood in other words the hood lock cannot be locked if the hood is opened Apart from the hood lock control there is an option for the control of the additional engine locking relay connected via normally closed scheme The hood lock is closed in the following cases Car security is activated the central lock is closed In 10 seconds after the ignition is off Anti Hi Jack mode is activated ri...

Page 5: ... Anti Hi Jack mode when the CAN bus lacks data required for CONTOUR operation or the IGLA system digital locking has failed In other cases the activation of the additional circuit is impossible Locking is disabled by entering the PIN code of IGLA system or by switching the ignition off status on yellow wire Locking procedure Locking is made via normally closed circuit This is an emergency locking ...

Page 6: ...an be tracked via analogue ignition input yellow wire Wiring scheme ATTENTION Grey and red wires should be simultaneously connected to power supply to connect with the IGLA anti theft device when it is in the PIN code change mode Ignition lock Blocking circuit 20A max Analog relay Siren To the hood lock activator Vehicle CAN bus ...

Page 7: ...White CAN L 7 Brown CAN H 8 Green with 0 2 mm2 section Negative output to the siren 250mA max 9 Blue Negative output to the locking relay 250mA max 10 Green with 0 75 mm2 section To the hood lock activator 12A max Power supply to open the lock 11 Purple To the hood lock activator 12А max Power supply to close the lock A Purple Normally closed contact B Green Normally opened contact C Black Common ...

Page 8: ...N code change mode can be used enter the PIN code once again with the accelerator pressed If the grey wire is used while connecting to CONTOUR module all previously connected to IGLA devices will stop functioning ATTENTION For the connection of the second and subsequent devices all previously connected devices shall be disconnected from CAN bus or power supply 2 Connect the hood lock control modul...

Page 9: ...ion 2 If locking takes place the second time 3 Anti Hi Jack mode is active 4 When the hood is opened while the lock is closed 5 In case of CAN bus short circuit 6 When new keys are attempted to be registered 7 When the CONTOUR analogue locking activates The Siren can be deactivated by entering the PIN code The Siren operating time is limited to 45 seconds with the turned off ignition ...

Page 10: ...y control 250 mА Contents of the set CONTOUR module 1 pcs Operating manual 1 pcs Packing 1 pcs Locking relay is supplied separately Made in Russia Manufacturer LLC DMA Group C RU АЛ14 В 10097 The developer and the manufacturer retain the right to make technical updates not specified in this operating manual To learn more visit our web site http author alarm com ...

Page 11: ...ge or absence of a factory trade label Only items in complete set and with the original packing are taken for warranty repair Absence of packing is regarded as noncompliance with transportation rules The warranty does not apply to the damage incurred to another equipment operating together with this device Item model ________________ Sale date ______ ____ ________ The contents of delivery ___ func...

Page 12: ...Supported Cars List App ...

Reviews: