APE4200

USER MANUAL

ECLIPSE F90 

(Master Environmental Controller) 

AutopilotControllers.com

Summary of Contents for ECLIPSE F90

Page 1: ...APE4200 USER MANUAL ECLIPSE F90 Master Environmental Controller AutopilotControllers com ...

Page 2: ...AutopilotControllers com 2 ...

Page 3: ...UMIDITY SETTINGS 8 HUMIDITY DEADBAND HYSTERESIS 8 HUMIDITY MIN MAX RECALL 8 HUMIDITY MODE SWITCH 8 TEMP DEADBAND OPTIONS 8 TEMP DEADBAND SETTING 8 CO2 MODE 8 HIGH TEMPERATURE PROTECTION 8 HOW TO SET HIGH TEMP LIMIT 8 DAYTIME MODE LED ERROR LEDS ERROR DISPLAY MESSAGES 9 SPECIFICATIONS 9 MOUNTING INSTRUCTIONS 10 MOUNTING THE UNIT TO A WALL 10 MOUNTING THE UNIT TO A GROW TENT 10 GENERAL WARNINGS 11 S...

Page 4: ...tive covers that prevent atmospheric moisture from entering the device through any unused outlets Rubber feet have also been added to the back of the unit for added protection when mounted This controller s sensitive and intelligent remote combination probe features a highly accurate dual beam NDIR CO2 sensor The probe can be placed up to 15 feet from the controller and has been designed to resist...

Page 5: ...PARTS LIST WHAT S IN THE BOX A B A Controller Unit B Sensor Unit C Mounting Hardware for walls D Mounting Hardware for grow tents D C 5 ...

Page 6: ...Y SETTING HUMIDITY MODE CO2 MODE HEATING OUTPUT COOLING OUTPUT CO2 OUTPUT HUMIDITY OUTPUT TEMP DEADBAND TEMP SETTING Click press knob turn to set click again to confirm Press both function knobs for Min Max recall Press both knobs for 3 seconds to calibrate CO2 Sensor Switch F C PHOTOCELL STATUS POWERINPUT SENSORCORD 6 ...

Page 7: ...ying CO2 that are also operating an exhaust fan for temperature control This setting minimizes CO2 loss when the exhaust fan is operating UNLOCK The CO2 enrichment device and any cooling device that is plugged in are independently controlled TEMPERATURE SETTINGS The unit offers both day and night temperature control Select either the heating or cooling mode option DAYTEMP SETTING There is a Day Co...

Page 8: ...arget and deadband hysteresis Click again to confirm the setting CO2 MODE PPM UP Increases the CO2 PPM when using a gas CO2 generator Fuzzy Logic Increases the CO2 PPM when using a compressed CO2 system PPM DOWN Decreases the CO2 PPM using a fan HIGH TEMPERATURE PROTECTION If when using a CO2 generator with this controller the environmental temperature exceeds the set limit the ECLIPSE F90 will de...

Page 9: ...D Press either of the corresponding knobs either of theTEMP or RH knobs to reset the error There are also four error LEDs on the bottom left of the controller These lights will identify which environmental factor the controller is reporting an error on SPECIFICATIONS Max amperage 14 5 amps 120VAC 60 Hz Power cord length 6 5 2 m Sensor cord length 15 4 5 m CO2 Range 400 2000 PPM CO2 Accuracy 100 PP...

Page 10: ... Secure the controller to one of the grow tent s vertical support rods with the included U bolt brackets 1 Install on the inside of the grow tent 2 Install on the outside of the grow tent note that this method requires puncturing four holes through the grow tent wall to allow the threaded ends of the U bolts to emerge through the grow tent s fabric wall 1 2 10 ...

Page 11: ...the power cord is damaged please stop using the product immediately Unplug the unit and contact the retailer you purchased it from 10 The unit is equipped with a circuit breaker that will automatically shut it down at once All outlets of the product all have the safety ground 11 Do not install the unit near any heat source 12 Do not block any ventilation openings in the controller housing 13 This ...

Page 12: ...on of incidental or consequential damages so the above limitations or exclusions may not apply to you Hydrofarm will at our discretion repair or replace the APE4200 covered under this warranty if it is returned to the original place of purchase To request warranty service please return the APE4200 with original sales receipt and original packaging to your place of purchase The purchase date is bas...