INSTALLATION
1. Avoid installation in outdoor, places with pets, air-
condition, heat source nearby, places with direct
sunshine and places under rotating objects.
2. Install on stable surface, without vibration.
3. Install the detector in places where an intruder may
passes easily.
INSTALLATION STEPS
1. Screw the bottom off and open the detector
2. Remove the PCB
3. Drill a wire hole in the rear housing
4. Install the rear housing in a suitable position
5. Fix the internal PCB
6. Connect the terminal block as follows
7. Place the detector cover
1
PIR-730 MAIN FEATURES
●
MCU control, resist false alarm efficiently
●
Double temperature compensation
●
Pulse count adjustment
●
White light interference immune
●
RF interference immune (20V/m-1GHz)
●
Fresnel lens optics
●
Wall/ceiling installation
●
Alarm output N.C. or N.O.
●
Alarm timer optional (3s or 30s)
●
Intelligent floating thresholds technology
●
Enhanced appearance design
●
SMT high stability production
PRODUCT INTRODUCTION
The PIR-730 is a
n
high stability
ceiling-mounted
passive infra red (PIR) detector. Adopts advanced
signal processing technology which provides high
detection ability and anti-false alarm ability.
MCU processing ensuring the reliability from
design basis. When an intruder passes through
the detection area, the detector will detect the
human body movements automatically. If any
movements, it will send alarm signal to the
connected alarm host. It suits for safety protection
in residential houses, villas, factories, shopping
malls, warehouses and office buildings etc.
TECHNICAL SPECIFICATION
Operation voltage: DC 9-16V
Current consumption:
≤
18mA
(
DC
12V
)
Detecting distance:
Φ
6m at
3
.
6m
of
ceiling
installation
Detecting speed: 0.3m/s-3m/s
Detecting an: 360°
Self-testing time: 60s
Alarm time: 3s/30s optional
Alarm indication: Red LED
Sensor: Double element Pyroelectric infrared sensor
Operating temperature: -10
℃
~ +50
℃
Environment humidity:
≤
95% RH(no coagulation)
Anti RF interference: 10MHz-1GHz 20v/m
Instillation Mode: Ceiling
mounted
Installation height: 2.5-3.6m
Alarm output: N.C. or
N.O. (DC28V
100mA)
Tamper output: N
.
C. (DC28V
100mA)
Outline Size:
Φ
100
*
36mm
WIRING TERMINAL BLOCK FIGURE
+12V DC
Positive
GND DC
Negative
ALARM Relay contacts
TAMPER Protection Switch
PIR-730 Installation Manual
GND
ALARM
TAMPER
+12V
PIR-730
Item:
4727_730 (A5DS)