Avisaro 4.0 Product Series 

Quick Guide 

4..20mA Data Logger & Gateway 

‘4.0 Sky’

  

M47724

 / 

C47724

 ) 

Version / Date: 2022/03/28 

 

 

 

 

 

Summary of Contents for C47724

Page 1: ...Jump to Table of Content 2022 03 28 Page 1 Avisaro 4 0 Product Series Quick Guide 4 20mA Data Logger Gateway 4 0 Sky M47724 C47724 Version Date 2022 03 28...

Page 2: ...GO connector 8 4 USB Storage Stick 9 4 1 Filesystem and Storage size 9 4 2 Formatting 9 4 3 Choosing the right memory stick 9 5 Interface description and Pin Layout 11 5 1 Micro USB Client 11 5 2 Anal...

Page 3: ...0mA 0 10V 18 6 10 1 Storage Format 18 6 10 2 Storage endpoint 19 6 10 3 Network endpoint 19 6 11 Data Endpoints USB Stick 20 6 11 1 Create new file policy 20 6 12 Data Endpoints Network endpoint 21 6...

Page 4: ...Jump to Table of Content 2022 03 28 Page 4 8 Declarations 30 8 1 EC EU Declaration of Conformity 30 9 Contact and Support 31...

Page 5: ...llowing link Link https www avisaro de files Avisaro 40_Docu M47724 C47724 QuickGuide pdf 2 4 LANGUAGE VERSIONS This document is available in English language only 2 5 OTHER DOCUMENTS Technical User M...

Page 6: ...eted documents are available Disadvantage is that in rare occasions a paragraph might have comments which do not fit to 100 in the place it is used 2 8 IMPRINT AND CONTACT This document is provided by...

Page 7: ...Red about 2sec than blue about 2sec Logger restarts This should not happen during normal operation Check power supply 1 On analog loggers e g 4 20mA and similar interfaces data are read continuously t...

Page 8: ...CONNECTOR Front with slot for USB stick Matches are shown just for size reference Reverse side shows the two WAGO connectors for data and power Optional a DIN rail fitting is available WAGO connector...

Page 9: ...as it is Use FAT32 as the desired format Windows Operating System does not allow to format sticks larger then 32 GByte with the FAT32 file system Usually sticks come pre formatted so you don t have to...

Page 10: ...technology memory sticks with an extremely high capacity are typically less robust than smaller memory sizes The loggers have a ring memory that can be optionally activated If the memory stick becomes...

Page 11: ...ic waste Heads up There are sometimes Micro USB cable which only do power supply but not data Those are used i e with mobile phones If the Avisaro device is powered but no data connection to the PC ju...

Page 12: ...orrect readings Make sure to update to a firmware larger to 2 65 Check chapter firmware update in this document for details Connector Interface Pin Signal Direction WAGO A ADC3 ADC4 4 20mA 1 ADC3 mA 2...

Page 13: ...o Device so that the new configuration takes effect Details are described further down in this document 6 2 CONCEPT OF OPERATION The Avisaro 4 0 is divided into sections Data are received through an I...

Page 14: ...older with all files You can run the exe directly from there Windows warns the user before installing or using software downloaded from the Internet So if you click on Avisaro_40_Companion_v2 56_Setup...

Page 15: ...Avisaro Device It should light up green when clicked The baudrate setting for if connected through real RS22 can be ignored This setting is used only in special projects and not scope of this documen...

Page 16: ...page 6 8 1 Global HW settings System functions Don t touch those settings unless advised by technical support team from Avisaro 6 8 2 Global HW settings Networking Activate the network interface which...

Page 17: ...naged in the same settings page 6 9 1 Sample Rate Select the desired sample rate in samples per seconds hz 6 9 2 Stream to In this point of time only Analog data generic can be selected 6 9 3 Graphic...

Page 18: ...Jump to Table of Content 2022 03 28 Page 18 6 10 DATA PROCESSING 4 20MA 0 10V Settings for collection 0 10V or 4 20mA analog data 6 10 1 Storage Format Storage format OFF This is the default setting...

Page 19: ...0MA 9 980 mA 0 730 mA 0 001 mA 0 001 mA 2022 03 02 15 45 35 330 20MA 9 980 mA 0 742 mA 0 001 mA 0 000 mA 2x Current mA NMEA Storage format example with the setting 2022 03 02 16 41 24 795 20MA 6 924 m...

Page 20: ...or higher required 6 11 DATA ENDPOINTS USB STICK The file handling is configured in this section Depending on the application choose when and how to create files 6 11 1 Create new file policy Descript...

Page 21: ...ew file If memory space is exceeded the oldest file is deleted Log file name yymmddhh txt every day Log file name yyyymmdd txt at new event time at new event keyword PDF every new start 6 12 DATA ENDP...

Page 22: ...casts Target port port data are sent to Local port port data are received see WiFi Setting for this device IP address TCP IP client Data is send and received using the TCP IP protocol The Avisaro devi...

Page 23: ...Local port port data are received see WiFi Setting for this device IP address 6 13 DATA ENDPOINTS CLOUD SETTINGS The Cloud features of the Avisaro devices are best described in separate application sp...

Page 24: ...stored are uploaded on an hourly base to the FTP server specified in the settings MQTT Client This feature is defined in customer specific projects only Store Collect Stored data are made available to...

Page 25: ...Jump to Table of Content 2022 03 28 Page 25 Check chapter Firmware and Configuration Update later in this document for details...

Page 26: ...most user friendly way to configure the Avisaro devices Use this as your preferred method See paragraph PC Companion Software for details on where to get and how to operate the software Find the compl...

Page 27: ...USB stick The SET PC_Headline_DataEndp TO RootDir Kapitel Companion Kapitel PC Headline DataEnd docx order is first the firmware update is performed second the configuration update is performed 7 2 FI...

Page 28: ...se broken devices needs to be send in to Avisaro for repair Background The configuration remains if not stated otherwise the same Thus all settings stay the same after a firmware update 7 2 3 Via PC C...

Page 29: ...but when the update is executed there is a window of 30 seconds which is sensitive to power failure Recommendations It is highly recommended to create a different user pointing to a different subdire...

Page 30: ...Jump to Table of Content 2022 03 28 Page 30 8 DECLARATIONS 8 1 EC EU DECLARATION OF CONFORMITY...

Page 31: ...of Content 2022 03 28 Page 31 9 CONTACT AND SUPPORT Please contact Avisaro if there are any questions Avisaro AG Grosser Kolonnenweg 18 E 30163 Hannover Germany Email support avisaro com End of this...