background image

Installation Guide 

& User Manual

 

Version: RH-UC085-201708 

 
 

 

5” High Under Cabinet Range Hoods

 

Models: RH-UC085 (30”, 36”)

 

 
 
 
 
 
 

          

STOP and read! Test before installing

 

 

1.  Please unpack the range hood and accessories carefully.   
2.  Remove the baffle filters, check any dent or damage inside and outside. 
3.  If found any loosing parts, please remove them. 
4.  Place the range hood on a flat stable surface, plug in 120V  AC  power 

source. Press the power button and the speed buttons to turn on.   

5.  Check if any unusual metal touching noise, check the speed variation, 

and press the Light button to check the lights. 

6.  Verify all functions per Section 9 RANGE HOOD OPERATIONS. 
7.  Refer to Section 10 TROUBLESHOOTING if any malfunction was found. 

 

IMPORTANT: 

 

Read and save these instructions. 

 

NOTICE: 

 

Installer: 

Leave this guide with the homeowner 

Homeowner: 

Keep this guide for future reference 

 

Summary of Contents for RH-UC085

Page 1: ...hem 4 Place the range hood on a flat stable surface plug in 120V AC power source Press the power button and the speed buttons to turn on 5 Check if any unusual metal touching noise check the speed variation and press the Light button to check the lights 6 Verify all functions per Section 9 RANGE HOOD OPERATIONS 7 Refer to Section 10 TROUBLESHOOTING if any malfunction was found IMPORTANT Read and s...

Page 2: ...by qualified person s in accordance with all applicable codes and standards including fire rated construction C When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities D Verify and ensure the rated voltage and frequency please refer to the rating label of the range hood is in compliance with the mains supply CONTENTS 1 KNOW BEFORE INSTALLATION 2 2 I...

Page 3: ...e If not 6 round metal duct try to get the converter reducer adapter elbow as shown in the pictures Damper is NOT included Because the damper generates NOISE when the shutters are flipping we DO NOT recommend installing the damper directly attached to the top vent of the range hood You can install the damper between ducts and close to the air outlet near roof or side wall If the roof cap or side w...

Page 4: ...ver Baffle Filters Rectangle Rear Vent Adapter For rear vent ONLY remove the TWO 2 rear vent covers remove one cover then see the other one inside install this rear vent duct adapter and the top vent cover 2 Rear Vent Covers 6 Top Vent Adapter 2 INCLUDED PARTS ACCESSORIES Note the supplied are subjected to change without notice due to product development ...

Page 5: ...ities Before servicing or cleaning unit unplug the power cord or switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outdoors DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Use only meta...

Page 6: ...ed in the area where it is started The fire department is being called You can fight the fire with your back to an exit To reduce the risk of injury to persons in the event of a gas leaks Extinguish any open flame DO NOT turn on the lights or any type of appliance Open all doors and windows to disperse the gas If you still smell gas call the gas company and fire department or 911 immediately Your ...

Page 7: ...recommended between stove top and the bottom of range hood The vent duct isn t included It is recommended that the range hood be vented vertically through the roof through 6 15 24 cm or bigger round metal aluminum vent work such as 6 in x 8 ft semi rigid aluminum flexible duct The size of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straig...

Page 8: ... Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will reduce its performance and efficiency If available also refer to stove top manufacturer s height clearance requirements and recommended hood mounting height above range Minimum Duct Size Round 6 minimum Rectangular 3 1 4 x 10 minimum requires a 6 to 3 1 4x10 adaptor not su...

Page 9: ...e rigid or semi rigid type metal aluminum ducts if available to maximize airflow Decide the location of the venting pipe from the hood to the outside Astraight short vent run will allow the hood to perform more efficiently Try to avoid as many transitions elbows and long run as possible This may reduce the performance of the hood IMPORTANT NEVER exhaust air or terminate duct work into spaces betwe...

Page 10: ...sed disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable ETL listed strain relief must be provided at each end of the power supply cable Specifications Specifications Body Design Seamless Stainless Steel Satin Finish Power Rating 120V 60Hz USA Canada standard General Input Power 153W 150W 2x1 5W Motor Input Power Max 150W 75W 75W Min 110W 55W 55W Ampere ...

Page 11: ...S 1 Installation planning Measure the distance between stove top and the bottom of range hood A distance of 27 to 30 is recommended Minimum 24 is required for safety concern Decide the venting method and the location of the venting pipe from the hood to the outside Purchase any necessary accessories from a hardware store such as duct elbow reducer damper duct tape screws etc Find and mark the stud...

Page 12: ... many mounting holes as needed to secure from the inside of hood 8 Use 6 round metal duct or semi rigid aluminum duct follow building codes in your area to connect the exhaust on the hood to the duct work above Use foil tape or duct tape to make all joints secure and air tight 9 Connect the range hood to a designated grounded standard outlet Or cut off the plug and connect three wires black white ...

Page 13: ...peed Control button can be activated Blower Speed Selection With the range hood is OFF press the Power Control On Off button once The LED on the Power Control button will be illuminated While the Power Control LED is illuminated press one of the four speed control button Quiet Low Medium and High to activate the desired speed the LED on the speed control button will turn on To change the fan speed...

Page 14: ...on The range hood might not have been secured properly on to the cabinet or wall The blower or fan seems weak Check that the duct sized used is at least 6 or 3 1 4 x 10 Range hood WILL NOT function efficiently with insufficient duct size For example 7 duct over 6 hole and loosely secured Check if duct is clogged or if damper unit half circular flapper is not installed correctly or opening properly...

Page 15: ... onto or into the control panel Follow directions of the stainless steel cleaner CAUTION DO NOT leave on too long as this may cause damage to hood finish Use soft towel to wipe off the cleaning solution gently rub off any stubborn spots Use dry soft towel to dry the hood After cleaning you may use nonabrasive stainless steel polish to polish and buff out the stainless luster and grain Always scrub...

Page 16: ...anty is extended to the original purchaser for products purchased for ordinary home use in the continental USA This Warranty Will Be Voided When Product damaged through negligence improper installation accident abuse misuse natural disaster insufficient or excessive electrical supply abnormal mechanical or environmental conditions or any unauthorized disassembly repair modification or failure to f...

Page 17: ...rranty service you may contact us its dealer or distributor from which you purchased the product Please confirm the terms of your dealer s or distributor s policies prior to contacting Typically you must include product identification information including model number and lot number with a detailed description of the problem you are experiencing You must also include proof of the date of original...