background image

RELEASE DATE

12-19-2019

REFERENCE

 

NUMBER

INS-2816-00

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • info@bklighting.com

B-K LIGHTING

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY 

DESCRIBE.  REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.

1/8”, 3/16” & 0.050” Allen Wrench
Waterproof Wire Connectors
Phillips Screwdriver

Warning

High Voltage

Hot Surface

NEEDED

FOR 

INSTALLATION:

By Others

Hydrolock Plate 

(factory wired to 

conduit assembly, 

arrives installed in 

CO2 Housing)

O-Ring

CO2 

Housing

Heavy Wall 

Composite 

Housing

 Faceplate

Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/dig-it for more information.

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS

AGI2 LED

 

·  Suitable for wet locations

IMPORTANT LISTINGS AND CERTIFICATIONS

AGI2 Solid State Fixture

Driver Assembly 

Plate With Quick 

Connects

1” Notch

Direct Burial 

Flexible 

Conduit with 

(3) 12Ga., 

THHN Wire

Mounting 

Collar

Optic

Heat 

Sink and 

OptiLock™ 

Assembly

LED 

Assembly 

and Optic 

Holder

Conduit

Assembly

Faceplate

Heavy Wall 

Composite 

Housing

Waterproof Wire 

Connectors

• Product must be installed by a qualified person in a manner 

consistent with its intended use and in compliance with the 

National Electrical Code, Canadian Electrical Code, and all Local and 

Provincial Codes. 

•  Follow product label information and instructions.

• Qualified Personnel with appropriate personal protective 

equipment must perform all servicing of this product.

•  Before wiring to power supply and during servicing, turn off and 

lock out power at fuse or circuit breaker before service.

• The use of accessory equipment not recommended by the 

manufacturer or installed contrary to instructions may cause an 

unsafe condition. The use of damaged components may cause an 

unsafe condition and void product warranty.

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY 

AND INSTALLATION INSTRUCTIONS

•  Do not block light emanating from product in whole or part, as 

this may cause an unsafe condition.

• Never operate the fixture with missing or damaged lens.  

Lens must be cleaned on regular basis.

• Entire fixture may become extremely hot. Do not touch hot 

lens or fixture body. 

•  Replace LED assembly only with correct wattage and type of 

power supply appropriate for LED assembly.

• All gaskets, o-rings and sealing surfaces must be kept clean 

during installation and service; failure to do this may cause an 

unsafe condition and void product warranty. 

INSTRUCTIONS PERTAINING TO 

A RISK OF FIRE, OR INJURY TO 

PERSONS IMPORTANT SAFETY 

INSTRUCTIONS

Lighted fixture is HOT!

WARNING - To reduce the risk of 

FIRE OR INJURY TO PERSONS: 

Turn off/unplug and allow to cool before replacing LED. 

Fixture gets HOT quickly! Contact only switch/plug when 

turning on.  Do not touch hot lens, guard, or enclosure. 

Keep fixture away from materials that may burn. 

 

Do not operate the luminaire fitting with a missing or 

damaged shield.  Do not touch the source at any time. Use 
a soft cloth or gloves. Oil from skin may cause damage.

SAVE THESE INSTRUCTIONS

Summary of Contents for AGI2

Page 1: ...al Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service The use of accessory equipment not recommended by the manufacturer or instal...

Page 2: ...e 18 wide and deep enough for faceplate height above grade as per lighting plan 2 Make watertight connections using provided waterproof wire nuts See wiring diagram Hydrolock Plate LINE COM GROUND DIM DIM WIRING DIAGRAM 3 For soil installation fill and tamp soil to the appropriate height Fixture is above grade specified by lighting plan Aiming Adjustment 1 Remove faceplate using 1 8 Allen wrench 2...

Page 3: ...f accessory lens if used faces LED 5 Install faceplate using 1 8 Allen wrench and hand tighten the faceplate screws in a star pattern to 30 lbs min Do not use a power tool to install screws Do not exceed 40 lbs 4 Remove any dirt or debris in O ring groove near top of housing Place O Ring inside of groove Failure to clean groove of debris will cause fixture to fail and void product warranty 6 Insta...

Page 4: ...in housing OptiLock is gravity held in place 8 To aim OptiLock vertically loosen two 2 1 4 20 screws using 3 16 Allen wrench Tilt swivel arm with LED and optic in desired aiming direction Tighten two 2 1 4 20 screws with 3 16 Allen wrench to secure position 2 Turn then lift OptiLock from housing Disconnect OptiLock assembly from driver assembly using quick disconnect 3 Remove optic by turning to t...

Page 5: ...n lift OptiLock from housing Disconnect OptiLock assembly from driver assembly using quick disconnect 9 Attach OptiLock assembly to installed driver assembly with quick disconnect Place OptiLock assembly in housing resting the OptiLock on the pins provided inside the housing Gravity will hold OptiLock in place 3 Remove optic by turning to the left to unlock optic from optic holder tabs and lift up...

Reviews: