background image

IMPOR

TANT

: T

O BE KEPT BY THE O

WNER

VEDANA

®

 

OWNER’S MANUAL

2019 EDITION

IMPORTANT INFORMATION FOR THE INSTALLER 
AND THE OWNER

The quest for your wellness

®

Summary of Contents for VEDANA

Page 1: ...IMPORTANT TO BE KEPT BY THE OWNER VEDANA OWNER S MANUAL 2019 EDITION IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER The quest for your wellness ...

Page 2: ......

Page 3: ...nts VEDANA OWNER S MANUAL WARRANTY 4 SAFETY INSTRUCTIONS 5 TECHNICAL SPECIFICATIONS 6 PARTS TOOLS 7 SITE PREPARATION 8 9 STRUCTURE INSTALLATION 10 11 ELECTRICAL INSTALLATION 12 FINISHING INSTALLATION 13 17 MIAPLUS CONTROL NAVIGATION 18 19 BLUETOOTH MUSIC 20 MAINTENANCE 21 22 TROUBLESHOOTING 23 24 956 chemin Olivier Lévis Québec G7A 2N1 T 418 831 7701 1 800 463 2187 F 418 831 6623 1 800 382 8587 in...

Page 4: ...a or on any other BainUltra product after the date of manufacture are expressly excluded from this limited warranty PROCEDURE Any defect involving BainUltra s potential liability under this limited warranty shall be reported to BainUltra within ten 10 days of its occurrence To assist you with your warranty please contact BainUltra s customer service by email telephone or fax between 8 a m to 6 p m...

Page 5: ...ude Inability to perceive heat Inability to recognize the need to exit the room Physical inability to leave the room Unawareness of danger Fetal injury in pregnant women Loss of consciousness If you are a pregnant women or a person who have had a stroke or have heart disease kidney failure or a history of heat stroke contact a doctor before doing a Thermotherapy session The use of drugs or alcohol...

Page 6: ...nnected to a 240 V circuit 40 Amp 19 5 8 45 7 cm 80 203 2 cm TECHNICAL SPECIFICATIONS Aromatherapy Thermotherapy Light therapy Chromatherapy Sound therapy 21 x 80 x 9 1 2 The manufacturer accepts a 1 4 0 64 cm variance There are variations on each product and specifications are subject to change as we improve our product The dimensions needed for site preparation and structure building may differ ...

Page 7: ...patents A PARTS INCLUDED B TOOLS REQUIRED PARTS TOOLS A 1 Vedana A 2 Nebulizer A 3 Essential oils bottle A 4 2 Hyperthermia warning sticker B 1 Drill B 2 24 Level B 3 Phillips screwdriver B 4 Measuring tape B 5 1 8 Allen key B 6 Hole saw B 7 Silicone B 8 24 Square B 9 Caulking gun B 4 B 1 B 2 B 8 B 3 B 5 B 7 B 9 B 6 IMPORTANT Vedana unit is delivered in a single box Please make sure that all parts...

Page 8: ... light pressure Never install any locking or latching on the door Make sure that the door can t cause any entrapment Fresh air intake Glass Door Minimum 3 Fiberglass insulation Allow a 10 in2 air outlet ideally in the top of the room facing the Vedana to ensure air circulation Minimum air intake of 24 in2 behind the Vedana Do not screw on the back wall facing the Vedana SITE PREPARATION Your Vedan...

Page 9: ...ome products specifications and services mentioned in this manual are described in pending patent applications or are protected by patents STRUCTURE AND INSTALLATION OF SUPPORTS 3 1 2 80 to 86 1 1 2 min Do not install shower faucets or a shower head any closer than 3 ft 36 from the Vedana WARNING 18 1 2 SITE PREPARATION ...

Page 10: ...l protection panel and air conduit Protection panel 1 800 463 2187 From 8 a m to 6 p m Monday to Thursday EST From 8 a m to 5 p m on Friday EST Printed in Canada Copyright July 2019 BainUltra All rights reserved 45200496 Some products specifications and services mentioned in this manual are described in pending patent applications or are protected by patents ...

Page 11: ...2 not included x12 Drill and screws 4 to 10 Always handle the Vedana with the help of another person to avoid breach and or injury When drilling holes be careful not to damage the stainless steel side panels WARNING STRUCTURE INSTALLATION Once the Vedana is fixed to the structure screw the small panel at the bottom of the structure It is strongly recommended to use 12 screws not included to fix th...

Page 12: ...ectrical connections must be made by a certified electrician in accordance with local provincial state and federal building electrical code regulations Make connections as shown below Make connections in the control box before connecting to power supply This unit is connected a 240 V circuit The unit s electrical system must be connected to a circuit protected by a 40 Amperes Class A ground fault ...

Page 13: ...atents INSTALLATION OF WALL PANELS GYPSUM Silicone FINISHING INSTALLATION INSTALLATION OF CERAMIC TILES Install ceramic tiles according to industry standards Never drill into the Vedana structure but only into the expressly designated places Humidity resistant gypsum or fiber cement 1 2 thick 1 2 to 1 finishing Ceramic tiles Gypsum or fiber cement Minimum 3 1 2 structure with minimum 3 fiberglass ...

Page 14: ...2019 BainUltra All rights reserved 45200496 Some products specifications and services mentioned in this manual are described in pending patent applications or are protected by patents FINISHING INSTALLATION INSTALLATION OF FRONT PANEL CONTROL AND AROMATHERAPY TUBE CONNECTIONS Hook up aromatherapy tube and control cable to protection panel Air conduit ...

Page 15: ...pecifications and services mentioned in this manual are described in pending patent applications or are protected by patents FINISHING INSTALLATION Aromatherapy module panel is not shown to see the components Connect the tube to the aromatherapy module Connect the electric plug Aromatherapy tube Screw protection panel Protection panel ...

Page 16: ...entioned in this manual are described in pending patent applications or are protected by patents Front panel Use a hand held screwdriver to avoid damaging the front panel Make sure to properly secure in place the 14 screws of the front panel Connect and test the control before final installation FRONT PANEL INSTALLATION CONTROL AND AROMATHERAPY TUBE CONNECTIONS Hook up aromatherapy tube and contro...

Page 17: ...All rights reserved 45200496 Some products specifications and services mentioned in this manual are described in pending patent applications or are protected by patents FINISHING INSTALLATION CAUTION SIGNAGE This WARNING sticker should affix close to the Vedana unit to be easily read by user ...

Page 18: ...FREEDOM On HARMONY WONDER Stop LOVE SESSIONS ECHO On VIVERE Stop 1 800 463 2187 From 8 a m to 6 p m Monday to Thursday EST From 8 a m to 5 p m on Friday EST Printed in Canada Copyright July 2019 BainUltra All rights reserved 45200496 Some products specifications and services mentioned in this manual are described in pending patent applications or are protected by patents ...

Page 19: ...t This allows you to set the desired temperature inside your Vedana Press Deactivate and the temperature gradually cools down depending on your Vedana s space insulation When you reach the desired tem perature press Activate and then Comfort and the temperature will remain steady 2 Lock To activate the Lock function using the and keys select the option Activate and to validate your choice When you...

Page 20: ...HESE STEPS TO PAIR YOUR DEVICE 1 The Bluetooth Module inside the Vedana is called in stream2 2 Open the Bluetooth settings on your device The location of the settings will depend on the device you are using 3 Make sure Bluetooth is on 4 Select in stream 2 in the list of discoverable Bluetooth devices detected nearby 5 When prompted enter 5555 as the PIN Code 6 Once the pairing is done select in st...

Page 21: ...polycarbonate and support posts of stainless steel MAINTENANCE Clean polycarbonate and stainless steel with a mild non abrasive product LIGHT THERAPY SYSTEM Your light therapy is generated by led light so no maintenance is required THERMOTHERAPY SYSTEM AIR FILTER TECHNICAL INFORMATION The air filter is found under the Vedana FREQUENCY the air filter must be cleaned twice a year More frequent clean...

Page 22: ...diffuser receptacle is made of polycarbonate Essential oil must be used in the diffuser only The diffusion nebulizer is made of glass Never over fill the diffuser Use diffuser only with quality essential oil and avoid buying low quality oil that could damage the Vedana FREQUENCY Add oil before each use Be careful not to overfill nebulizer MAINTENANCE Wash receptacle with water and mild soap after ...

Page 23: ... It vibrates or makes noise The air filter under the unit has not been put back in place and an object could have been vacuumed Please contact BainUltra It turns off before the end of the therapy and will not start again The manual thermal protection has tripped related to a major problem The fan then stops immediatly Please contact BainUltra THERMOTHERAPY SITUATIONS POSSIBLE ISSUES POSSIBLE SOLUT...

Page 24: ...udio station reset all Bluetooth functions on the device you are trying to pair up or connect with the station and start over with the pairing process My device is connected but the music is not playing In some instances the in stream 2 will not be able to launch the music application of the connected device Make sure the music application is open and running on the front page of your mobile devic...