background image

 

 

 

 

 

 
 
 
 
 

ES-817 

Rev D 

 

SPECIAL INSTRUCTIONS FOR INSTALLING MASONEILAN 

SVI3 IN AREAS WHERE THERE IS A POTENTIAL FOR EXPLOSIVE GAS AND 

DUST ATMOSPHERES 

 
 

 

Summary of Contents for Masoneilan SVI3

Page 1: ...ES 817 Rev D SPECIAL INSTRUCTIONS FOR INSTALLING MASONEILAN SVI3 IN AREAS WHERE THERE IS A POTENTIAL FOR EXPLOSIVE GAS AND DUST ATMOSPHERES...

Page 2: ...6 INTRINSICALLY SAFE REQUIREMENTS 6 6 1 I S BARRIERS 6 6 2 INSTALLED MODULE BASED TEMPERATURE RATINGS ADJUSTMENTS 6 7 AGENCY MARKINGS 7 7 1 AGENCY APPROVALS 7 7 2 US AND CANADIAN STANDARDS 9 7 3 ENCL...

Page 3: ...m The SVI3 positioner is designed by Dresser LLC 12970 Normandy Blvd Jacksonville FL 32221 USA The SVI3 Positioner is manufactured in India 2 Model Codes Covered by this Document Model Code SVI3 ABCDE...

Page 4: ...on and other safety measures may be required to maintain a safe environment Verify that the markings on the label are consistent with the application Verify that the air supply pressure cannot exceed...

Page 5: ...ations as shown Shown with cover removed 4 2 Entries and Cable Glands Certified cable glands are required based on the hazardous area the device is installed in The NPT conduit plug supplied with the...

Page 6: ...al 1 13 N m Options Terminal Connections o Min 0 5 N m o Max 0 6 N m Conductor Size Range 4 20 mA Input Terminals 22 AWG to 12 AWG Options Terminal Connections 26 AWG to 14 AWG 6 Intrinsically Safe Re...

Page 7: ...Zone 21 Ex ia tb IIIC T20091 C Db Intrinsically Safe Explosive Gas Base Positioner Temperature Classification IEC Ex ia IIC T6 T4 Ga T4 Ta 55 C to 85 C ATEX II 1G Ex ia IIC T6 T4 Ga T5 Ta 55 C to 75 C...

Page 8: ...EC Class II Division 1 Groups E F G T6 T4 Class III Zone 20 Ex ia IIIC T20091 C Da Increased Safety Non Incendive Marking for Explosive Gas Dust Temperature Classification IEC Ex ec ic IIC T6 T4 Gc T4...

Page 9: ...1 60079 11 1203 60079 31 60079 7 and 121201 Certified to CSA STDs C22 2 94 1 94 2 61010 1 12 60079 0 60079 1 60079 11 30 60079 31 25 60079 7 and 213 7 3 Enclosure Ratings NEMA 4X IP66 Type 4X 7 4 Ope...

Page 10: ...8 2 SVI3 Options Module 1 2 3 R E M Remote Mount 4 20 mA OUT SW 1 2 PV 1 5 VDC OPTIONAL HAND HELD COMMUNICATOR 1 2 4 3 1 2 4 3 1 2 4 3 Optional Field Load SEE NOTE 8 3 2 Certified Active or Passive IS...

Page 11: ...nd EN60079 14 as they apply to the specific category 8 2 1 4 to 20mA Input Terminals These terminals power the SVI3 and are equipped on the Main Module This is a standard component within every SVI3 p...

Page 12: ...tions card add on Entity NIFW Parameters Uo Io Co Lo Po 5 4 Vdc 5 8 mA 64 F 500 H 8 mW 8 3 Entity Requirement Cable capacitance and inductance plus the I S apparatus unprotected capacitance Ci and ind...

Page 13: ...s For more information contact Masoneilan Dresser LLC 12970 Normandy Blvd Jacksonville FL 32221 USA Dresser LLC For assistance contact the nearest sales office your local representative or email svisu...

Page 14: ...Modify Model Code Identifier G and H added statement on replacement of NPT s 12 10 20 C 2 4 1 D M ECO 0043804 Removed note on use of Teflon tape changed Model Code Identifier H such that any single ch...

Reviews: