background image

Doc #: 161041_00
Part #:79151
Released: 04/08/2016

Sectional Door Opener 

Instruction Manual

SDO-3V2  

Controll-A-Door

®

 S

Controll-A-Door

®

 S

& PanelPro

®

SDO-4V1  

PanelPro

®

Summary of Contents for Controll-A-Door Advance

Page 1: ...Doc 161041_00 Part 79151 Released 04 08 2016 Sectional Door Opener Instruction Manual SDO 3V2 Controll A Door S Controll A Door S PanelPro SDO 4V1 PanelPro ...

Page 2: ...ce 10 To Increase Force Pressure 10 To Decrease Force Pressure 10 To Recall Factory Set Force 10 To Recalculate Force Margins 10 13 Auto Close Auxiliary 11 Safety Beams 11 Auto Close Option 11 Auxiliary Output 11 14 Coding a Transmitter 12 Storing the Transmitter Code 12 Coding the Courtesy Light 12 Coding Vacation Mode 12 Coding a Transmitter to enable AUX Output 12 Setting the Transmitter to Ope...

Page 3: ... 9kgs Practice correct lifiting techniques when required to lift the door as per installation instructions Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm ground that will take the weight without the legs sinking Ensure user has 3 points of contact while on ladder Crush injury from unsecured door Place a 2 metre exclusion zone around area under the door whi...

Page 4: ...tural support You will need to locate the structural beams in the ceiling which are generally 400mm apart ii does it have exposed beams The opener is mounted to a perforated angle which must be securely fastened to a structural support like the exposed beams You may need to install a 40mm thick board not supplied between structural supports b Look at the wall above the garage door i Is it brick Th...

Page 5: ...5 11 1 x Pin 0890 12 2 x Clevis Pin 0829 13 2 x Hex Serration flange nut M8 14 4 x Hex flange screw taptite S M4 x 10 PLUS 15 2 x Track Bracket 16 1 x Pre Assembled Single Piece C Rail 10 00 min MINIMUM HEAD ROOM FOR STEEL RAIL 25mm DOORS HIGHEST POINT 15 1 16 5 4 6 7 12 8 14 11 9 13 10 5 Position Perforated Angle The Opener a MUST BE installed in a dry position protected from weather b REQUIRES p...

Page 6: ... opener failure may ensue causing serious personal injury and or property damage DO NOT DO IT YOURSELF If sufficient structural support can not be found contact a door profressional for installation DIY c Using step ladder and a level transfer this height to the wall above the door and mark a line 60mm above it across the centre line Mounting The Wall Bracket a Draw two lines extending 21 5mm from...

Page 7: ...ent moisture on the C rail running into the powerhead it is recommended a strip of silicon sealant is placed across the top of the C rail just before the opener Ceiling Beams that run towards the door requires 1 x perforated L shape metal strip and 2 x shorter perforate L shape metal drop down strips Ceiling Beams that run parallel to the door requires 2 x perforated L shape metal strips and 2 x s...

Page 8: ...traight arm 5 with bolts 10 and nuts 13 supplied in the accessory pack Connect the straight arm 5 to the 8 7 7 12 9 4 13 6 10 9 12 8 5 10 Connect to Power Initial Preparation a Move the door to the half way position b Remove the clear button cover from the unit NOTE This cover has a label that says Do not remove however this only applies during normal operation This cover must be removed to setup ...

Page 9: ...the MINUS button will inch the door closer to the ground c If the door overshoots press the PLUS button to move the door in the open direction d When the door is at the desired close position press the LIMIT SET button the OPEN LIMIT LED will now flash e Press and hold the PLUS button until the door reaches your desired open limit position Single presses of the PLUS button will inch the door open ...

Page 10: ...rgins a Press and hold the FORCE MARGIN SET Button for six 6 seconds the beeper will sound once b The door will start to move and re calculate force margins The door can move between the open and close limit positions up to four 4 times depending on the position of the door and the power up condition c A single beep will be heard once the process is complete d Test the force again as per Testing C...

Page 11: ...oken the door will remain open until the path is broken If the opener incurs a physical obstruction i e not from the Safety Beams while closing the door it will re open and not Auto Close until the Safety Beam s path is broken again To enable the Auto Close function unscrew the back cover from the opener to gain access to the control board and remove the AUTO CLS ACLS shunt next to the programmer ...

Page 12: ...de The opener can be programmed into a Vacation Mode where the opener will not respond to any transmitter except the button of the transmitter that was programmed for vacation mode a Press the DOOR CODE button three 3 times the DOOR CODE LED will illuminate and the courtesy light will flash slowly b Press one of the four 4 buttons on the transmitter for two 2 seconds the DOOR CODE LED will begin t...

Page 13: ...opener is in Code Learn mode If a valid code is not stored within 15 seconds the opener will exit Code Learn d Press the transmitter button one of four that you want to control the door The DOOR CODE LED will flash e Press the same transmitter button again The DOOR CODE LED will illuminate for one second then go out f The transmitter button is now coded press to test Remotely Coding Transmitters U...

Page 14: ... wet DO NOT spray with water DO NOT open the protective covers DO NOT operate opener if cable is damaged DO NOT DO IT YOURSELF Keep the garage door balanced Sticking or binding doors must be repaired Garage doors door springs brackets and their hardware are under extreme tension and can cause serious personal injury DO NOT attempt any garage door adjustment DO NOT use if repair or adjustment is ne...

Page 15: ...nually re engage the opener after the door is closed 17 Operating your Opener To Operate the opener a Press the programmed transmitter button until your door begins to move usually 2 seconds Make sure you can see the door when you use the transmitter b If you are in a vehicle you should aim the transmitter through your windscreen as shown c Check that the door is fully open or closed before you dr...

Page 16: ...tion 1 OPERATE Opens stops closes the door 2 CODING LED Red Flashes when a code is being stored or when the transmitter button is pressed 3 DOOR CODE Blue Is used for storing or erasing transmitter buttons for door operation 4 DOOR STATUS LED Yellow Illuminates when Service is due 5 OPEN LED Green Illuminates and flashes as the door opens and remains on when the open limit position has been reache...

Page 17: ...47 433 92 434 37MHz Receiver code storage capacity 8 X Tri Tran 4 button Transmitters 8 X Tri Tran 4 button Transmitters Coding System Tri Tran Technology Tri Tran Technology Coding type Non linear encryption algorithm Non linear encryption algorithm Number of code combinations Over 100 billion random codes Over 100 billion random codes Transmitter battery CR2032 3 Volts CR2032 3 Volts Courtesy li...

Page 18: ...t chain is not moving Damage motor assembly Contact your dealer for support The transmitter range varies or is restricted Variations are normal depending on conditions e g temperature or external interference The battery life is exhausted Position of the transmitter in the motor vehicle Make sure you can see the door when you use the transmitter Check the battery status by pressing a button flashi...

Page 19: ... cause Remedy The SERVICE LED has started to flash and is beeping numerous times A Fault has been detected The fault will be active each time an attempt is made to operate the door Record opener function How many beeps then press the SET button once to reset the opener If the fault continues to be tripped contact 13 62 63 for support The Open Green LED and Close Red LED are flashing alternatively ...

Page 20: ... and social benefits WARNING Prior to disposal recycling or collection all battery terminals must be securely insulated with a non conductive material to prevent any two batteries from short circuiting and generating heat during storage or transport Battery terminals may be insulated with electrical tape or batteries may be individually packaged in a non conductive material e g plastic bag or orig...

Page 21: ...fault of 3000 cycles which is the recommended service interval AUX OSC 0V SB 2 0V SB 1 v When this counter expires the yellow SERVICE LED will light up and opener beep three times at the start of each cycle In addition the courtesy light will flash and opener beep five times at the end of open cycle when the door is fully open These warning signals will self extinguish after 30 cycles When this se...

Page 22: ...h 6 this warranty does not extend to and B D will be relieved of all obligations responsibilities and liabilities in the event that defects in the Product are directly or indirectly in the opinion of B D due to or resulting from a unreasonable use the Product not being used correctly in accordance with the Instruction Manual or other unreasonable use b instructions failure to observe any instructi...

Page 23: ...rsonal use when entry into the house may be via the garage Wall Button Transmitter Allows you to operate the opener within 10 metres of the door Ideal for mounting inside the house Wireless Keypad The entry keypad allows entry to the garage without using a transmitter Battery Back up The opener has a provision for a Battery Back Up kit that allows continued operation of the door in the absence of ...

Page 24: ... 20 B D Doors is a division of B D Australia Pty Ltd ABN 25 010 473 971 Is your opener beeping or flashing It may be time for a service for more details see section 22 For a service contact your dealer using the details below Dealer copyright 2016 ...