Configurable FlexPower Node with discrete and thermocouple I/O

The SureCross

®

 wireless system is a radio frequency network with integrated I/O that can

operate in most environments and eliminate the need for wiring runs. Wireless networks are
formed around a Gateway, which acts as the wireless network master device, and one or
more Nodes.

• Wireless industrial I/O device with up to two selectable discrete inputs, one NMOS dis-

crete output, and four thermocouple inputs (defaults to J-type)

• One thermistor input used for integrated cold junction compensation (CJC)
• Selectable transmit power levels of 250 mW or 1 Watt and license-free operation up to 4

watt EIRP, with a high-gain antenna, in the U.S. and Canada for 900 MHz

• FlexPower

®

 power options allows for +10 to 30V dc, solar, and battery power sources for

low power applications.

• DIP switches for user configuration
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple Ac-

cess (TDMA) control architecture ensure reliable data delivery within the unlicensed In-
dustrial, Scientific, and Medical (ISM) band

• Transceivers provide bidirectional communication between the Gateway and Node, in-

cluding fully acknowledged data transmission

• Lost RF links are detected and relevant outputs set to user-defined conditions

For additional information, the most recent version of all documentation, and a complete list of accessories, refer to Banner Engineering's
website, 

www.bannerengineering.com/surecross

.

Models

Frequency

Power

Housing

I/O

DX80N9X2S-P3

900 MHz ISM
Band

10 to 30V dc or battery supply mod-
ule

IP67, NEMA
6

Inputs: Two selectable discrete, four ther-
mocouple, one thermistor for CJC
Outputs: One NMOS sinking discrete

DX80N9X1S-P3E

10 to 30V dc or integrated battery

IP54, NEMA
4

DX80N2X2S-P3

2.4 GHz ISM
Band

10 to 30V dc or battery supply mod-
ule

IP67, NEMA
6

DX80N2X1S-P3E

10 to 30V dc or integrated battery

IP54, NEMA
4

DX80...C (IP20; NEMA 1) models are also available. To order this model with an IP20 housing, add a C to the
end of the model number: DX80N9X2S-P3C.
The integrated battery models are also available without batteries. If you purchase a model without the bat-
tery, Banner Engineering recommends using the XENO XL-205F battery or equivalent. For DX99 models, on-
ly a XENO XL-205F battery is certified.

WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death.
 This device does NOT include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.

Important: Never Operate 1 Watt Radios Without Antennas.
To avoid damaging the radio circuitry, never power up SureCross Performance or SureCross MultiHop (1
Watt) radios without an antenna.

SureCross Performance FlexPower Node

 

 

P/N 155863_web
Rev. C

11/7/2012

Summary of Contents for SureCross Performance DX80N2X1S-P3E FlexPower

Page 1: ...ete list of accessories refer to Banner Engineering s website www bannerengineering com surecross Models Frequency Power Housing I O DX80N9X2S P3 900 MHz ISM Band 10 to 30V dc or battery supply mod ule IP67 NEMA 6 Inputs Two selectable discrete four ther mocouple one thermistor for CJC Outputs One NMOS sinking discrete DX80N9X1S P3E 10 to 30V dc or integrated battery IP54 NEMA 4 DX80N2X2S P3 2 4 G...

Page 2: ...g its Modbus RTU RS 485 connection is a Modbus slave to a Modbus RTU host controller the wireless network may contain up to 47 Nodes in a single wireless network and the Gateway holds the Modbus registers of all wireless devices within the network A Node is a wireless network end point device used to provide sensing capability in a remote area or factory The Node collects data from sensors and com...

Page 3: ... To access the internal DIP switches follow these steps 1 Unscrew the four screws that mount the cover to the bottom housing 2 Remove the cover from the housing without damaging the ribbon cable or the pins the cable plugs into 3 Gently unplug the ribbon cable from the board mounted into the bottom housing For integrated battery models no ribbon cable and Class I Division 2 certified devices ribbo...

Page 4: ...1600 degrees Fahrenheit or 1600 degrees Celsius switch the DIP switch to the ON position and use low resolution mode In high resolution the device cannot store values larger than 1600 Temperature Units Use the DIP switch to specify if the temperature is stored in degrees Fahrenheit or Celsius The default position is OFF setting the temperature to Fahrenheit For Celsius measurements set this switch...

Page 5: ... OUT x GND Ground dc common connection PWR Power 10 to 30V dc power connection DX80 C Wiring Wiring power to the DX80 C models varies depending the power requirements of the model Terminal Label Gateway DX85 10 to 30V dc Powered Nodes Battery Powered Nodes V 10 to 30V dc 10 to 30V dc Tx RS485 D1 B V dc common GND dc common GND dc common GND Rx RS485 D0 A B 3 6 to 5 5V dc Connecting dc power to the...

Page 6: ... optional 2 RS 485 D1 B RS 232 Tx 3 dc common GND dc common GND 4 RS 485 D0 A RS 232 Rx The BAT connection is a low voltage connection to the internal battery Remove the internal battery if a low voltage source is connected to the BAT terminal When powering the device from the integrated battery the BAT connection must remain open Terminal Block IP54 A4 A1 A3 A2 GND A3 PWR DO1 DI1 A1 A1 A3 A2 A2 A...

Page 7: ...mocouples are available by configuring the Node Thermocouple Range F Range C Type B 212 to 3 272 F 100 to 1 800 C Type C 32 to 4 208 F 0 to 2 320 C Type E 58 to 1 832 F 50 to 1 000 C Type J 292 to 1 382 F 180 to 750 C Type K 292 to 2 282 F 180 to 1 250 C Type L 328 to 1 652 F 200 to 900 C Type N 32 to 2 192 F 0 to 1 200 C Type R 32 to 2 912 F 0 to 1 600 C Type S 32 to 2 642 F 0 to 1 450 C Type T 2...

Page 8: ...m an integrated battery ship from the factory in storage mode to conserve the battery To wake the device press and hold button 1 for five seconds To put any FlexPower or integra ted battery SureCross radio into storage mode press and hold button 1 for five seconds The radio is in storage mode when the LEDs stop blinking but in some models the LCD remains on for an additional minute after the radio...

Page 9: ...risk of explosion if the battery is re placed incorrectly 4 After replacing the battery allow up to 60 seconds for the device to power up Properly dispose of your used battery according to local regulations by taking it to a hazardous waste col lection site an e waste disposal center or other facility qualified to accept lithium batteries As with all batteries these are a fire explosion and severe...

Page 10: ...OFF Condition PNP Less than 5V NPN Greater than 2V or open Thermocouple Inputs Sample Rate 8 seconds Report Rate 32 seconds Accuracy 0 1 of full scale reading 0 8 C Resolution 0 1 C 24 bit A D converter Thermistor used for CJC Model BWA THERMISTOR 001 Accuracy 0 4 C 10 to 50 C Up to 0 8 C 40 to 85 C Resolution 0 1 C 24 bit A D converter Discrete Output Update Rate 1 second ON Condition Less than 0...

Page 11: ... the most recent version of any documentation refer to our website www bannerengineering com 2006 2010 Banner Engineering Corp All rights reserved Banner Engineering Corp Limited Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one year following the date of shipment Banner Engineering Corp will repair or replace free of charge any prod...