Configurable FlexPower Node with discrete and thermocouple I/O

The SureCross

®

 wireless system is a radio frequency network with integrated I/O that can

operate in most environments and eliminate the need for wiring runs. Wireless networks are
formed around a Gateway, which acts as the wireless network master device, and one or
more Nodes.

• Wireless industrial I/O device with up to two selectable discrete inputs, one NMOS dis-

crete output, and four thermocouple inputs (defaults to J-type)

• One thermistor input used for integrated cold junction compensation (CJC)
• Selectable transmit power levels of 250 mW or 1 Watt and license-free operation up to 4

watt EIRP, with a high-gain antenna, in the U.S. and Canada for 900 MHz

• FlexPower

®

 power options allows for +10 to 30V dc, solar, and battery power sources for

low power applications.

• DIP switches for user configuration
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple Ac-

cess (TDMA) control architecture ensure reliable data delivery within the unlicensed In-
dustrial, Scientific, and Medical (ISM) band

• Transceivers provide bidirectional communication between the Gateway and Node, in-

cluding fully acknowledged data transmission

• Lost RF links are detected and relevant outputs set to user-defined conditions

For additional information, the most recent version of all documentation, and a complete list of accessories, refer to Banner Engineering's
website, 

www.bannerengineering.com/surecross

.

Models

Frequency

Power

Housing

I/O

DX80N9X2S-P3

900 MHz ISM
Band

10 to 30V dc or battery supply mod-
ule

IP67, NEMA
6

Inputs: Two selectable discrete, four ther-
mocouple, one thermistor for CJC
Outputs: One NMOS sinking discrete

DX80N9X1S-P3E

10 to 30V dc or integrated battery

IP54, NEMA
4

DX80N2X2S-P3

2.4 GHz ISM
Band

10 to 30V dc or battery supply mod-
ule

IP67, NEMA
6

DX80N2X1S-P3E

10 to 30V dc or integrated battery

IP54, NEMA
4

DX80...C (IP20; NEMA 1) models are also available. To order this model with an IP20 housing, add a C to the
end of the model number: DX80N9X2S-P3C.
The integrated battery models are also available without batteries. If you purchase a model without the bat-
tery, Banner Engineering recommends using the XENO XL-205F battery or equivalent. For DX99 models, on-
ly a XENO XL-205F battery is certified.

WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death.
 This device does NOT include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.

Important: Never Operate 1 Watt Radios Without Antennas.
To avoid damaging the radio circuitry, never power up SureCross Performance or SureCross MultiHop (1
Watt) radios without an antenna.

SureCross Performance FlexPower Node

 

 

P/N 155863_web
Rev. C

11/7/2012

Summary of Contents for SureCross Performance DX80N9X2S-P3 FlexPower

Page 1: ...te list of accessories refer to Banner Engineering s website www bannerengineering com surecross Models Frequency Power Housing I O DX80N9X2S P3 900 MHz ISM Band 10 to 30V dc or battery supply mod ule...

Page 2: ...its Modbus RTU RS 485 connection is a Modbus slave to a Modbus RTU host controller the wireless network may contain up to 47 Nodes in a single wireless network and the Gateway holds the Modbus regist...

Page 3: ...To access the internal DIP switches follow these steps 1 Unscrew the four screws that mount the cover to the bottom housing 2 Remove the cover from the housing without damaging the ribbon cable or the...

Page 4: ...600 degrees Fahrenheit or 1600 degrees Celsius switch the DIP switch to the ON position and use low resolution mode In high resolution the device cannot store values larger than 1600 Temperature Units...

Page 5: ...OUT x GND Ground dc common connection PWR Power 10 to 30V dc power connection DX80 C Wiring Wiring power to the DX80 C models varies depending the power requirements of the model Terminal Label Gatewa...

Page 6: ...optional 2 RS 485 D1 B RS 232 Tx 3 dc common GND dc common GND 4 RS 485 D0 A RS 232 Rx The BAT connection is a low voltage connection to the internal battery Remove the internal battery if a low volta...

Page 7: ...ocouples are available by configuring the Node Thermocouple Range F Range C Type B 212 to 3 272 F 100 to 1 800 C Type C 32 to 4 208 F 0 to 2 320 C Type E 58 to 1 832 F 50 to 1 000 C Type J 292 to 1 38...

Page 8: ...an integrated battery ship from the factory in storage mode to conserve the battery To wake the device press and hold button 1 for five seconds To put any FlexPower or integra ted battery SureCross r...

Page 9: ...isk of explosion if the battery is re placed incorrectly 4 After replacing the battery allow up to 60 seconds for the device to power up Properly dispose of your used battery according to local regula...

Page 10: ...FF Condition PNP Less than 5V NPN Greater than 2V or open Thermocouple Inputs Sample Rate 8 seconds Report Rate 32 seconds Accuracy 0 1 of full scale reading 0 8 C Resolution 0 1 C 24 bit A D converte...

Page 11: ...the most recent version of any documentation refer to our website www bannerengineering com 2006 2010 Banner Engineering Corp All rights reserved Banner Engineering Corp Limited Warranty Banner Engine...

Reviews: