background image

The bluetooth name and Bluetooth registered trademarks are owned by Bluetooth SIG, Inc., and are used by Baracoda under license. The Baracoda names and Baracoda trademarks are
own by Baracoda. All specifi cation are subject to change without notice - Non contractual pictures © Baracoda - All rights reserved

Baracoda, Inc. (US Offi ce) 

Baracoda SA (Europe Offi ce: France)

45 Main street - Suite 616 - Brooklyn, NY 11201 

30 Avenue de l’Amiral Lemonnier - 78160 Marly-Le-Roi

Ph: 718 488 9600 - Fx: 718 488 9601 

Ph: +33 1 30 08 89 00 - Fx: +33 1 30 08 89 98

RoadRunners Linear Imager

© B

aracoda™ - 

Sept

 2005

Important notice

Every effort is made to ensure the accuracy of 

our product information; however, we accept no 

responsability for errors or omissions including, but not 

limited to, the implied warranties of merchantability and 

fi tness for a particular purpose. We shall not be liable for 

errors contained herein or for incidental consequential 

damages in connection with the furnishing, performance, 

or use of this material.

Specifi cations or version may be subject to change 

without notice. The actual specifi cation and version are 

based on the product delivered.

Introduction

Scanning a series of programming bar code labels can 
confi gure the scanne

r.

Please verify that your Roadrunners has a firmware version 
equal or superior to 2.

5

 before using it with this 

programming Guide. Some functionalities may not work with
older versions of the firmware. Refer to the Baracoda-
Manager documentation in order to know how to upgrade
your scanner. 
 
 

Programming Guide

Summary of Contents for RoadRunners Laser

Page 1: ...ever we accept no responsability for errors or omissions including but not limited to the implied warranties of merchantability and tness for a particular purpose We shall not be liable for errors con...

Page 2: ...X 1 ASCII Table A Z a z 0 9 ponctuation Control characters 20 APPENDIX 2 24 INTRODUCTION Please verify that your Roadrunners has a firmware version equal or superior to 2 5 before using it with this p...

Page 3: ...Real Time with No Data Loss Mode ON By reading the following barcode you will empty the internal memory of the scanner Empty memory V T V T F N C 4 N U L N U L F F F F er ase st or ed bar codes 1 3 Ba...

Page 4: ...in and again This acknowledgment is disabled in default settings It is strongly recommended to set this protocol acknowledgment on when using the scanner with the BaracodaManager Enables Baracoda head...

Page 5: ...els Appendix 1 as on a calculator following the timestamp format shown above For example to set the current time at 16th May 2007 3 25 pm the user will scan Set Timestamp label 0 label 7 label 0 label...

Page 6: ...on the decoder thus allowing user to aim at the correct barcode while pressing the trigger the second time will activate the decoder thus allowing the RoadRunners to actually decode the barcode In au...

Page 7: ...and bufferisation Forces the RoadRunners in Real Time mode with data acknowledgement Erases all codes in memory The BRR should have been previously set in the No data loss mode ON V T V T d N U L S O...

Page 8: ...ou can use this option to enable or disable the buzzer and or the Led You can also invert the led position LED CONFIG default V T V T F N C 4 S O N U L S O H N U L F F F F l eds def aul t LED CONFIG i...

Page 9: ...U L E N Q H T N U L F N C 4 E T X F F F F sni f f per i od 500m s Sniff period 300ms V T V T NUL E NQ HT NUL F NC4 SOH F NC4 a F F F F Set sni f f per i od 300m s 1 7 2 Power emission settings You can...

Page 10: ...pr ef i x of f SUFFIX on V T V T F N C 4 h N U L S O H F N C 4 A F F F F suf f i x on SUFFIX off V T V T F N C 4 h N U L S O H F N C 4 F F F F suf f i x of f max length of the Suffix Prefix is 32 cha...

Page 11: ...RoadRunners Linear CMOS Programming guide Oct 05 Baracoda 2005 10 24 L F L F E N D F F F F END of Conf i g...

Page 12: ...tted V T V T F N C 4 v N U L S O H N U L F F F F Di sabl e AI M Sym bol of y I dent i f i er Tr ansm i ssi on Symbology identifier AIM transmitted V T V T F N C 4 v N U L S O H S O H F F F F Enabl e A...

Page 13: ...op not transmitted V T V T F N C 4 N U L E O T F D S O H J F F F F Codabar start stop transmitted V T V T F N C 4 N U L E O T F D S O H I F F F F CODABAR s s t r ansm i t t ed Codabar check digit AIM...

Page 14: ...T X C d F F F F CODE11any l engt h Code 11 barcode length Min 6 V T V T F N C 4 N U L E N Q J E S T X A A C K F F F F CODE11 M i n l engt h 6 2 6 Code 39 settings Code 39 active V T V T F N C 4 N U L...

Page 15: ...T V T F N C 4 N U L E N Q E E S T X A A C K F F F F CODE39 M i n l engt h 6 2 7 Code 93 Settings Code 93 not active V T V T F N C 4 N U L E O T B D S O H B F F F F Di sabl e CODE93 Code 93 active V T...

Page 16: ...not t r ansm i t t ed Interleaved 2 of 5 barcode length minimum length 6 V T V T F N C 4 N U L E N Q G E S T X A A C K F F F F I nt er l eaved 2of 5 M i n l engt h 6 Interleaved 2 of 5 barcode length...

Page 17: ...cked and transmitted V T V T F N C 4 N U L E N Q H D S T X E G F F F F STD25 check di gi t checked and t r ansm i t t ed Standard 2 of 5 check digit mod 10 checked but not transmitted V T V T F N C 4...

Page 18: ...sm i ssi on UPC EAN check digit EAN 8 not transmitted V T V T F N C 4 N U L E O T M D S O H H F F F F Di sabl e EAN8 check di gi t t r ansm i ssi on UPC EAN UPC number system UPC A transmitted V T V T...

Page 19: ...oding UPC A UPC E EAN 8 EAN 8 transmitted as EAN 13 V T V T F N C 4 N U L E O T M D S O H X F F F F Tr ansm i t EAN8 as EAN13 2 13 Set min or Max length option The following is a procedure to follow f...

Page 20: ...E L F L F Code 39 L F L F F L F L F Codabar L F L F G L F L F Interleaved 2 of 5 L F L F H L F L F Standard 2 of 5 industrial 2 of 5 L F L F J L F L F Code 11 L F L F K L F L F MSI L F L F L L F L F...

Page 21: ...O L F L F O L F L F C L F L F C L F L F P L F L F P L F L F D L F L F D L F L F Q L F L F Q L F L F E L F L F E L F L F R L F L F R L F L F F L F L F F L F L F S L F L F S L F L F G L F L F G L F L F...

Page 22: ...L F r L F L F r L F L F f L F L F f L F L F s L F L F s L F L F g L F L F g L F L F t L F L F t L F L F h L F L F h L F L F u L F L F u L F L F i L F L F i L F L F v L F L F v L F L F j L F L F j L F...

Page 23: ...L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F _ L F L F _ L F L F _ L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F L F t i l de Decimal numb...

Page 24: ...Characters Name Programming label CR L F L F C R L F L F CR EOT L F L F E O T L F L F EOT ETX L F L F E T X L F L F ETX LF L F L F L F L F L F LF NUL L F L F N U L L F L F NUL SOH L F L F S O H L F L...

Page 25: ...racter is determined by summing the option values of each symbology If the sum is greater than 9 use A B C D E F in the place of 10 11 12 13 14 and 15 Code 39 Option Values 0 No check character or Ful...