background image

ENABLING BRIGHT OUTCOMES

MDMC-12133

User Guide

Coronis Uniti

Summary of Contents for Coronic Uniti

Page 1: ...ENABLING BRIGHT OUTCOMES MDMC 12133 User Guide Coronis Uniti...

Page 2: ...Registered address Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV Beneluxpark 21 8500 Kortrijk Belgium www barco com en support www barco com...

Page 3: ...ttach the connector compartment cover 21 3 10 Fixation of the foot on the desk 23 3 11 VESA mount installation 23 3 12 First time starting up 26 4 Daily operation 27 4 1 Recommendations for daily oper...

Page 4: ...ompliance check 43 5 22 4 DICOM calibration 43 5 22 5 Reset DICOM calibration 44 5 22 6 DICOM error threshold 44 5 23 Image scaling 44 5 24 Image source selection modes 45 5 25 Grayscale conversion mo...

Page 5: ...5 K5902079 07 Coronis Uniti Welcome 1...

Page 6: ...ional image over your entire field of view Use the instructions in this guide to install your Coronis Uniti display and discover the productive features and included accessories CAUTION Read all the i...

Page 7: ...7 K5902079 07 Coronis Uniti Parts controls and connectors 2...

Page 8: ...ront view Overview Image 2 1 Front view 1 I Luminate Left key 2 Right key 3 Menu key 4 Standby key 5 Power status indicator light Power On 6 Power status indicator light Standby 7 I Guard 8 Ambient li...

Page 9: ...compartment cover 1 Connector compartment cover 2 Tilt lock pin only for transportation 3 Tilt swivel foot 4 Cable duct 5 Foot lock pin only for transportation 6 SoftGlow Task light 7 SoftGlow Wall l...

Page 10: ...ector see tip below 7 USB downstream connector see tip below 8 USB downstream connector see tip below Please connect your keyboard or mouse to your PC rather than to the Uniti USB ports when hibernate...

Page 11: ...K5902079 07 Coronis Uniti 11 Image 2 4 Film clip MultiTouchPad The MultiTouchPad enables and controls SpotView Image 2 5 MultiTouchPad Parts controls and connectors...

Page 12: ...K5902079 07 Coronis Uniti 12 Parts controls and connectors...

Page 13: ...are using a Barco display controller please consult the user guide delivered with it to do this For a list of compatible display controllers please refer to the latest version of the compatibility ma...

Page 14: ...ay from the display and lift the cover upwards 3 Remove the cover 3 2 Unlocking the tilt mechanism In the factory the tilt system in the display stand is locked with a red pin to prevent damage during...

Page 15: ...re 3 3 Unlocking the height mechanism In the factory the height positioning system in the display stand is locked with a red pin to prevent damage during transportation You ll have to remove this pin...

Page 16: ...he factory the height positioning and the tilt system in the display stand are locked with red pins to prevent damage during transportation You ll have to remove both pins before adjusting your displa...

Page 17: ...and its stand 3 5 Connecting the signal cables To get access to the connectors remove the connector compartment cover See Removing the connector compartment cover page 14 To connect the signal cables...

Page 18: ...ead of the display controller to the other DisplayPort connector with one of the supplied DisplayPort cables 3 Connect a PC USB downstream connector to the display s USB upstream connector by means of...

Page 19: ...re undisturbed communication and to make optimal use of MediCal QAWeb and the Barco intuitive workflow tools 3 6 Connecting the power cable To connect the power cable to the display 1 Connect the supp...

Page 20: ...ct power supply the display will not start up 3 7 Mounting the film clip To mount the film clip The film clip can be mounted on the top side of the display 1 Position the film clip on the top side of...

Page 21: ...ew around the display s The SpotView vanishes when no finger is pressing on the MultiTouchPad unless the left side of the MultiTouchPad button is held down 3 9 Routing the cables Reattach the connecto...

Page 22: ...low you to fix the cables for better shielding of the cables To reattach the connector compartment cover 1 Reattach the connector compartment cover by sliding the cover s top You ll hear a click sound...

Page 23: ...risk of injury WARNING Never move a display attached to an arm by pulling or pushing the display itself Instead make sure that the arm is equipped with a VESA approved handle and use this to move the...

Page 24: ...it can be used with an arm stand according to the VESA 200 x 100 mm or VESA 100 x 100 mm standard Therefore the tilt swivel foot must be removed from the panel 1 Fasten the height mechanism of the foo...

Page 25: ...0 mm VESA solution or 4 screws M4 x 6 mm for a 100 x 100 mm VESA solution WARNING Never move a display attached to an arm by pulling or pushing the display itself Instead make sure that the arm is equ...

Page 26: ...the Windows start up messages will appear once the boot procedure is finished Your Coronis Uniti display will be running in a basic video mode at a default refresh rate when first time starting up If...

Page 27: ...27 K5902079 07 Coronis Uniti Daily operation 4...

Page 28: ...se technology based on pixels As a normal tolerance in the manufacturing of the LCD a limited number of these pixels may remain either dark or permanently lit without affecting the diagnostic performa...

Page 29: ...t is fully started To switch your display to Stand by using the keys Switching off the display can be done by 1 Push the standby key shortly for three times After the second push the OSD message Power...

Page 30: ...se the menu key Use the standby key to cancel adjustments or exit a sub menu Exit all OSD menus at once by touching the standby key for approximately 2 seconds The key icons are displayed above the ke...

Page 31: ...d by touching the I luminate left key When touching the I Luminate key the display will enter the I Luminate mode for approximately 1 minute Touch the I Luminate key again to immediately switch back t...

Page 32: ...hange the viewing mode 1 While no OSD menu is on the screen press the Left key and Right key simultaneously to change the viewing mode 2 Toggle the available viewing modes see Viewing modes page 40 by...

Page 33: ...33 K5902079 07 Coronis Uniti Advanced operation 5...

Page 34: ...Enter the Automatic Close submenu 4 Select Enabled Disabled as desired and confirm 5 3 Power LED About the power LED To prevent distractions the power LED is dimmed by default when the display is swit...

Page 35: ...d by mode manually until the power lock function is disabled again To enable disable the power lock function 1 Bring up the OSD main menu 2 Navigate to the Configuration User Interface Controls menu 3...

Page 36: ...time by automatically switching off the backlight when the display is not used for a specified period of time By default DPMS mode is enabled on your display but it also needs to be activated on your...

Page 37: ...ou can avoid or significantly reduce the occurrence of this phenomenon by enabling the delayed power down option This option will keep the display s backlight running for 4 hours after DPMS mode is ac...

Page 38: ...ifferent I Luminate modes Only full screen I Luminate is available in this case To set the I Luminate film position 1 Bring up the OSD main menu 2 Navigate to the Configuration I Luminate menu 3 Enter...

Page 39: ...hange the color temperature of your display Color temperature can only be changed on your display when color presets is set to user Therefore please refer to Color presets page 39 to do this To change...

Page 40: ...at in medical images certain grayscale color parts contain more diagnostic information then others To respond to these conclusions display functions have been defined These functions emphasize on thes...

Page 41: ...efer to Display functions page 40 to correctly set the display function The American Association of Physicists in Medicine AAPM composed a list of pre defined reading rooms Each of these reading rooms...

Page 42: ...you to run a display calibration or compliance test directly from the display using the OSD menus described in the next sections Embedded QA will use the front sensor I Guard to measure the necessary...

Page 43: ...ing extra information is shown Backlight runtime elapsed since latest calibration display function ambient light compensation reading room Current DICOM Settings Display Function Shows the current dis...

Page 44: ...hreshold to define the DICOM compliance can be modified in steps of 5 starting from 5 to 30 When the maximum deviation is not bigger than the selected threshold the compliance check will be OK To set...

Page 45: ...cting this mode the video settings become available for the selected video input signal on each side of the display Expert mode This mode is intended for displaying and manually configuring one or two...

Page 46: ...D format 1 Bring up the OSD main menu 2 Navigate to the Configuration Image Sources Input Settings DisplayPort 1 2 EDID menu 3 Enter the EDID format submenu 4 Select one of the available format and co...

Page 47: ...isplay status About display status The Status submenu of the OSD menu provides info on the current status of your display runtimes temperatures etc the status of the connected image sources video enco...

Page 48: ...K5902079 07 Coronis Uniti 48 Advanced operation...

Page 49: ...49 K5902079 07 Coronis Uniti Cleaning your display 6...

Page 50: ...hol solvents at higher concentration 5 Strong alkalis lye strong solvents Acid Detergents with fluoride Detergents with ammonia Detergents with abrasives Steel wool Sponge with abrasives Steel blades...

Page 51: ...51 K5902079 07 Coronis Uniti Repackaging instructions 7...

Page 52: ...age 7 1 2 Lock the height mechanism at the lowest display position by inserting the hook pin in the back of the stand Caution Make sure that the hook pin is inserted deep enough until only the red par...

Page 53: ...iti 53 Image 7 3 4 Tilt the display in the most upwards position Image 7 4 5 Slide the small buffer between the display and the stand Image 7 5 6 Tilt the display back to the most downward position Re...

Page 54: ...e at the back of the display Caution Make sure that the tilt lock pin is inserted deep enough until only the red part of the pin is visible Image 7 7 Image 7 8 8 Place the display in the bottom box so...

Page 55: ...cardboard compartments in the bottom buffers Image 7 10 10 Position the 2 top buffers on the display and cardboard compartments Image 7 11 11 Slide the accessory box and the display controller box in...

Page 56: ...dicated cutout Image 7 13 13 Slide the top box over the display in the bottom box Caution Make sure that the position of the lock cutouts in the bottom box and top box fit together Image 7 14 14 Inser...

Page 57: ...K5902079 07 Coronis Uniti 57 Image 7 15 15 Turn each lock a quarter turn to the right Image 7 16 16 The Coronis Uniti system is ready to be shipped Image 7 17 Repackaging instructions...

Page 58: ...K5902079 07 Coronis Uniti 58 Repackaging instructions...

Page 59: ...59 K5902079 07 Coronis Uniti Important information 8...

Page 60: ...fe support equipment The user should not touch the equipment nor its signal input ports SIP signal output ports SOP and the patient at the same time Power connection Equipment with external 24 VDC pow...

Page 61: ...ter If the equipment does not operate normally when the operating instructions are followed Adjust only those controls that are covered by the operating instructions since improper adjustment of other...

Page 62: ...below lists the names and contents of toxic and or hazardous substances that Barco s product may contain The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Ind...

Page 63: ...use The MDMC 12133 is intended to be used in displaying and viewing digital images including standard and multi frame digital mammography for review analysis and diagnosis by trained medical practiti...

Page 64: ...ld be avoided because it could result in improper operation If such use is necessary this equipment and the other equipment should be observed to verify that they are operating normally WARNING Use of...

Page 65: ...e humidity should be at least 30 Electrical fast transient burst IEC 61000 4 4 2 kV for power supply lines 1 kV for input output lines 100 kHz repetition frequency 2 kV for power supply lines 1 kV for...

Page 66: ...z and 800 MHz the higher frequency range applies These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and peopl...

Page 67: ...symbols Symbols on the device On the device or power supply you may find the following symbols nonrestrictive list Indicates compliance with Part 15 of the FCC rules Class A or Class B Indicates the...

Page 68: ...tors on the device Indicates the DisplayPort connectors on the device Indicates the legal manufacturer Indicates the manufacturing date yy xx Indicates the temperature limitations9 for the device to s...

Page 69: ...isclosure of a Barco software product in any form is authorized The specifications of Barco products are subject to change without notice Trademarks All trademarks and registered trademarks are proper...

Page 70: ...deo input signals DisplayPort 1 2 USB ports 1x USB 2 0 upstream endpoint 3x USB 2 0 downstream Power rating 24 VDC 16 25 A 5 VDC 0 1 A Power requirements This device shall only be powered by the medic...

Page 71: ...N CSA C22 2 No 60601 1 14 EMI specific IEC 60601 1 2 2014 ed4 EN 60601 1 2 2015 ed4 FCC part 15 Class B ICES 001 Level B VCCI Japan Environmental China Energy Label EU RoHS China RoHS REACH Canada Hea...

Page 72: ...NY THEORY OF LIABILITY MORE INFORMATION DETAILS IS TO BE FOUND IN EACH SPECIFIC OPEN SOURCE LICENSE With respect to GPL LGPL or similar licenses with regard to corresponding source code access and aut...

Page 73: ...K5902079 07 Coronis Uniti 73 Important information...

Page 74: ...V Beneluxpark 21 8500 Kortrijk Belgium Registered address Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com K5902079 07 06 09 2018 Barco NV President Kennedypark 35 8500 Kortrijk B...

Reviews: