background image

o

 

Manual #: 26-0903001-00 

o

 

Revision: 01.1 

 

 

 

 

 

MatrixPRO-II  

HD/3G SDI series

 

User manual 

Rev. 1.1 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for MatrixPRO-II 3G/HD/SD-SDI

Page 1: ...o Manual 26 0903001 00 o Revision 01 1 MatrixPRO II HD 3G SDI series User manual Rev 1 1 ...

Page 2: ...ncy energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area may cause harmful interference in which case the user will be responsible for correcting any interference Guarantee and Compensation Barco provides a guarantee relating to perfect manufacturing as part of the leg...

Page 3: ... will be rendered invalid Not included in the guarantee coverage are system failures which are attributed to programs or special electronic circuitry provided by the purchaser e g interfaces Normal wear as well as normal maintenance are not subject to the guarantee provided by Barco either The environmental conditions as well as the servicing and maintenance regulations specified in this manual mu...

Page 4: ...11101 Trade Center Drive Rancho Cordova California 95670 USA Phone 916 859 2500 Fax 916 859 2515 Barco N V Noordlaan 5 8520 Kuurne BELGIUM Phone 32 56 36 82 11 Fax 32 56 35 16 51 Website www barco com Technical Support Customer Service Portal www barco com esupport 866 374 7878 Events 24 7 866 469 8036 Digital Cinema 24 7 ...

Page 5: ... power cord is essential for safe operation Grounding the Product This product is grounded through the grounding conductor of the power cord To avoid electrical shock plug the power cord into a properly wired receptacle before connecting to the product input or output terminals A protective ground connection by way of the grounding conductor in the power cord is essential for safe operation Use of...

Page 6: ...esence of important operating and maintenance servicing instructions in the literature accompanying the appliance AVETISSEMENT Le point d exclamation dans un triangle equilatéral signale à alerter l utilisateur qu il y a des instructions d operation et d entretien tres importantes dans la litérature qui accompagne l appareil VORSICHT Ein Ausrufungszeichen innerhalb eines gleichwinkeligen Dreiecks ...

Page 7: ...xPRO II HD 3G SDI Series User s Guide Rev 1 1 7 Change History Date ECP Description Approved By 0 0 5 20 10 578607 User s Guide GKOU 1 1 3 09 11 586286 Added default IP address Added interface commands appendix Added MP II 3G Configuration Tool GKOU ...

Page 8: ...de 14 3 2 1 Router mode on NxN square routers 14 3 3 SW7 Power alarm 18 3 4 SW8 Power up mode 18 3 5 Switching time 19 3 6 Configuring protocol options 19 4 LED status indication 20 4 1 Start up 20 4 2 Alarm states 20 4 3 Ethernet states 20 5 Router communication 21 5 1 Serial connection 21 5 1 1 Maximum cable length RS 232 21 5 2 Ethernet connection 22 6 Control Panel operation 23 6 1 Button desc...

Page 9: ...rixPRO II 3G HD SD SDI Routers Rev 1 1 MatrixPRO II HD 3G SDI Series User s Guide Rev 1 1 9 B 2 Request X Point Status 31 B 3 Router Ping 32 B 4 Level List 32 Appendix C Barco MPII 3G Configuration Tool 33 ...

Page 10: ...th front indicators Future proof and flexible product range Barco s MatrixPRO II 3G HS SD SDI series is ideal for general events fixed installations on air routing mobile outside broadcast applications and sophisticated A V applications 1 1 Product versions The following versions of the Barco MatrixPRO II 3G HD SD SDI Routers are available 1RU Depth 5cm R9004661 8x8 HD 3G Digital Video Router Mult...

Page 11: ...W R9871081 0 35 kg N A AC Mains 2 2 Power Supply SL PWR 40 40W Power Supply Unit AC Supply voltage range 100 240VAC 50 60Hz Max 1 6A AC Mains connector IEC 320 DC output 15V max 2 2A 15V max 1 35A Maximum 43W DC connector DB9 female Status monitoring Via LED in front of the router CP Safety standards Compliant with CE EN60950 UL 1950 CSA22 2 2 3 Control Function Description Connector Serial Port R...

Page 12: ...ic up to 300m 270Mbps typical Belden 8281 Electrical signal outputs Connector 75 ohm BNC female Impedance 75 ohm nominal Return loss 15dB 5MHz 1 485Ghz 10dB 1 5GHz 3GHz Signal level 800mVp p 10 Rise fall time 20 80 SD limit 0 4ns 1 5ns 0 5ns rise fall variation HD limit 270ps 100ps rise fall variation 3G HD limit 135ps 50ps rise fall variation Amplitude overshoot 10 Signal polarity Non inverting e...

Page 13: ...SYNC Synchronization signal in Black burst composite tri level sync reference input with passive loop through for vertical interval switching LOOP Synchronization signal out Loop through of SYNC input NCB IN OUT N A ETHERNET 10 100Base T Ethernet bus for external router control RS 232 RS 232 for external control protocols POWER A 15VDC power connector POWER B 15VDC power connector redundant supply...

Page 14: ...yers 4x4 8x8 16x16 3 layers N A 5x5 10x10 4 layers 2x2 4x4 8x8 Switches 5 6 on the configuration switch set the router s mode The Router Management System software must be configured according to the mode chosen on the router The modes can be switched according to the following pattern SW 5 SW 6 Router mode OFF OFF 1 router layer OFF ON 2 router layers ON OFF 3 router layers ON ON 4 router layers ...

Page 15: ...r 2 Output 1 5 1 5 2 6 2 6 3 7 3 7 4 8 4 8 2 layers based on a 16x16 router Layer 1 Input Layer 1 Output 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 8 8 8 8 Layer 2 Input Layer 2 Output 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 8 16 8 16 2 layers based on a 32x32 router Layer 1 Input Layer 1 Output 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 16 16 16 16 Layer 2 Input Layer 2 Output 1 17 1 17 2 18 2 18 3 19 3 19 4 20 4 20 16 ...

Page 16: ...7 2 7 3 8 3 8 4 9 4 9 5 10 5 10 Layer 3 Input Layer 3 Output 1 11 1 11 2 12 2 12 3 13 3 13 4 14 4 14 5 15 5 15 In Output 16 is not in use in this router setup 3 router layers based on a 16x16 router 3 layers based on a 32x32 router Layer 1 Input Layer 1 Output 1 1 1 1 2 2 2 2 3 3 3 3 10 10 10 10 Layer 2 Input Layer 2 Output 1 11 1 11 2 12 2 12 3 13 3 13 10 20 10 20 Layer 3 Input Layer 3 Output 1 2...

Page 17: ...2 Output 1 3 1 3 2 4 2 4 Layer 3 Input Layer 3 Output 1 5 1 5 2 6 2 6 Layer 4 Input Layer 4 Output 1 7 1 7 2 8 2 8 4 layers based on a 16x16 router Layer 1 Input Layer 1 Output 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 Layer 2 Input Layer 2 Output 1 5 1 5 2 6 2 6 3 7 3 7 4 8 4 8 Layer 3 Input Layer 3 Output 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 Layer 4 Input Layer 4 Output 1 13 1 13 2 14 2 14 3 15 3 15 4 16...

Page 18: ... setting is Power Alarm disabled Changing this from default setting should only be done when using two redundant power supplies 3 4 SW8 Power up mode Switch 8 on the configuration switch defines the power up mode on NxN square routers The MatrixPRO II router provides two modes for powering up the system The power up options can be switched according to the following pattern SW 8 Power Up mode OFF ...

Page 19: ...rmats are PAL NTSC 750 50p 750 60p 1125 50i and 1125 60i 3 6 Configuring protocol options TCP IP This is the default option for the Barco MatrixPRO II HD 3G SDI routers Selecting this protocol disables the RS 232 port of that device RS232 The serial protocol can be selected from the configurator software Selecting the RS232 protocol disables the Ethernet port of that device Connection to the route...

Page 20: ...LED state is here described with twenty letters each representing 100ms which totals to an alarm sequence of two seconds The X indicates that the LED keeps the color it has the moment the alarm sequence begins green yellow or no light Description LED state Alarm Comment Continuous green light GGGGG GGGGG GGGGG GGGGG No alarm Status is OK Continuous yellow light YYYYY YYYYY YYYYY YYYYY Unable to co...

Page 21: ...te communication control protocol Example The protocol parameters s are as follows Bit rate 19200 bit s Data bits 8 bits Stop bits 1 Parity No parity The DB9 female connector for the serial port s of the router has the following pin out Pin RS 232 mode 1 Not in use 2 Tx 3 Rx 4 Not in use 5 GND 6 GND 7 RTS 8 CTS 9 Do Not Connect Note that if the standard RS 232 cable specification DCE is followed A...

Page 22: ...the responsibility of the installer user to secure a proper installation of the Ethernet connection All Barco MatrixPRO II routers and IP based Control Panels are connected together through an Ethernet Switch A Barco MatrixPRO II device has only one physical Ethernet connection If redundant control is required this limitation has to be solved by the control system The default IP address is 192 168...

Page 23: ... will not be used Toggle status changes will be stored in flash and used when the panel is powered up later When a panel is powered on it will search for connected routers If no routers are found the A V Toggle button will be disabled no light in the button This can happen if the panel is powered up before any routers are connected or if there is something wrong with the cabling To re enable the A...

Page 24: ...ent from the panel until the Take button is pressed The last selected buttons and the take button will blink until the Take button is pressed and the command is sent from the panel Output An Output button is used for selecting an output Selecting an output activates it so that it is switched to the next input that is selected Input An Input button switches the active output to the selected input I...

Page 25: ...meet the guaranteed performance specification under the following environmental conditions Operating room temperature range 0 C to 45 C Operating relative humidity range 95 non condensing 2 The equipment will operate without damage under the following environmental conditions Temperature range 10 C to 55 C Relative humidity range 95 non condensing ...

Page 26: ...ad Pb 汞 汞 汞 汞 Mercury Hg 镉 镉 镉 镉 Cadmium Cd 六价铬 六价铬 六价铬 六价铬 Hexavalent Chromium Cr VI 多溴联苯 多溴联苯 多溴联苯 多溴联苯 Polybrominated biphenyls PBB 多溴二苯醚 多溴二苯醚 多溴二苯醚 多溴二苯醚 Polybrominated diphenyl ethers PBDE All products referred to in Chapter 1 1 O O O O O O SL PWR 40 SL PWR 90 O O O O O O O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below t...

Page 27: ...e it is not possible to return the product to Barco or its agents for recycling the following general information may be of assistance Before attempting disassembly ensure the product is completely disconnected from power and signal connections All major parts are marked or labeled to show their material content Depending on the date of manufacture this product may contain lead in solder Some circ...

Page 28: ... 1 1 28 A 3 Declarations of Conformity DESCRIPTION 3G HD SD SDI Video Routers in the Barco MatrixPRO II series DIRECTIVES this equipment complies with LVD 73 23 EEC EMC 2004 108 EEC HARMONISED STANDARDS applied in order to verify compliance with Directive s EN 55103 1 1996 EN 55103 2 1996 ...

Page 29: ...O II HD 3G SDI Series User s Guide Rev 1 1 29 Appendix B Remote Commands Description x X point Take ls Status X point level ping Router ping llist Level list Default Address 192 168 0 245 port 4381 Connection to the router will be lost after 20 seconds ...

Page 30: ...rc dests levels level levels levels level level dests dest dests dests dest dest level The level number Source number in the range from zero to one less than the number of inputs on the level src can also be one of the following characters d Disconnect Used when a destination is not connected to any source o Out of range Used when a destination is connected to a source not included in a level This...

Page 31: ...tch input 1 to output 12 in level 1 B 2 Request X Point Status This command is used to requests the X point status of all destinations on a specified level Command s l level1 CC LF LF Response LF x l level src dest LF x l level src dest LF CC LF LF Example Command Echo Desired action s l1 X l1 15 0 X l1 15 1 X l1 15 2 X l1 15 3 X l1 15 4 X l1 15 5 X l1 15 6 X l1 15 7 X l1 15 8 X l1 15 9 X l1 15 10...

Page 32: ...Command ping CC LF LF Response ping LF pong LF CC LF LF Example Command Echo Desired action ping pong B 4 Level List This command is used to the get list of all levels in the system Command llist LF LF Response llist LF l level size format description LF l level CC LF LF Example Command Echo Desired action llist L1 16x16 Video 3GHD SDI Video Level Provide the list in level 1 ...

Page 33: ...eries User s Guide Rev 1 1 33 Appendix C Barco MPII 3G Configuration Tool The Barco MPII 3G Tool is a software utility that allows the user to Read the IP settings Modify and Save IP settings Switching the communication between Ethernet and the serial RS 232 protocols ...

Reviews: