background image

_________________________________________________________     

  Manual #: 26-1302001-00 
  Revision: 01 

 

 
 
 

MatrixPRO-II 

 

DVI 16x16 Matrix Router 

 

User’s Guide 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for MatrixPRO-II DVI 16x16

Page 1: ..._________________________________________________________ Manual 26 1302001 00 Revision 01 MatrixPRO II DVI 16x16 Matrix Router User s Guide...

Page 2: ...ntee On receipt the purchaser must immediately inspect all delivered goods for damage incurred during transport as well as for material and manufacturing faults Barco must be informed immediately in w...

Page 3: ...as comments or examples and are not to be understood as advertising for the products or their manufactures __________________________________________________________________ Company Address Barco Inc...

Page 4: ...nductor in the power cord is essential for safe operation Grounding the Product This product is grounded through the grounding conductor of the power cord To avoid electrical shock plug the power cord...

Page 5: ...rtungsanweisungen in der Dem Great beiliegenden Literatur aufmerksam zu machen Disposal of the Product wast Electrical and Electronic Equipment This symbol on the product indicates that under the Euro...

Page 6: ...nistry of Information Industry of China in the section Limit Requirements of toxic substances in Electronic Information Products Component Name Hazardous Substances or Elements Pb Hg Cd Cr6 PBB PBDE P...

Page 7: ...rco Barco EFUP EFUP EFUP EFUP All Electronic Information Products EIP that are sold within Chinese Mainland must comply with the Electronic Information Products Pollution Control Labeling Standard of...

Page 8: ...outer ________________________________________________________________________ User s Guide Rev 01 8 CHANGE HISTORY Rev Date ECP Description Approved By 00 6 7 13 606947 User s Guide GKOU 01 7 29 13 6...

Page 9: ...18 4 4 FUNCTION mode 18 4 4 1 Gateway 19 4 4 2 Subnet Mask 19 4 4 3 IP Address 19 4 4 4 MAC Address 20 4 4 5 UDP Port Number 20 4 4 6 Video Generator 20 4 4 7 Monitoring Output 20 4 4 8 EDID Configur...

Page 10: ...01 10 7 2 2 Input and output status 32 7 2 3 Network setting 33 7 2 4 Monitor output port setting 33 7 2 5 EDID control command 33 7 2 6 HDCP Setting 34 7 2 7 Baud rate setting for RS 232 34 7 2 8 Con...

Page 11: ...ult Mode Auto Mix Mode Output Copy Mode Supports various control methods Front panel button operation Command input Through RS 232 and Telnet connections Built in web panel control TCP IP PC program b...

Page 12: ...the equipment in a manner not specified by the manufacturer may result in irrecoverable damage Keep the unit away from liquid magnetic and combustible substances Do not place heavy weight on the unit...

Page 13: ...l Input and output cards interface ports and power supplies are placed on the rear panel as shown below Input bay for 4 input cards left side Output bay for 4 output cards right side SERVICE RJ 11 rec...

Page 14: ...play size luminance data and for digital displays only pixel mapping data Once the graphic source reads the information set usually during the booting process the EDID conveys the optimal format for a...

Page 15: ...ts is created and used to avoid any compliance problems in the field Figure 2 1 EDID operation As depicted in the Figure once the EDID is configured each EDID is stored in EEPROM in Input ports As a r...

Page 16: ...ect Local Area Connection and right click to open property Select Internet Protocol Version 4 TCP IPv4 Enter IP Subnet mask Gateway and DNS server address compatible with the current network setting o...

Page 17: ...Code and Phone Number fields but select available COM port of PC and then click OK In COM Properties window set the parameters as below Bits per second baud rate 115200 115200 is default baud rate of...

Page 18: ...LINK mode It unlinks input output connection 1 Press LINK key button 2 Press SHIFT key button UnLINK should now be displayed 3 Press the input key button for the routing you would like to clear 4 Pres...

Page 19: ...000 001 4 4 2 Subnet Mask The cursor shows that it is selected and activated Input 3 key button decreases the number Input 4 key button increases the number Input 1 and 2 key buttons move the cursor...

Page 20: ...Input 3 key button decreases the number Input 4 key button increases the number Monitoring Output Old Input 01 New Input 01 1 Connect a display to the Monitoring Output port and any video sources to...

Page 21: ...Default EDID to allocated input as below EDID Configure EDID Copying EDID Reading 3 2 If you select Auto Mix Mode mixed EDID of all attached displays will be saved in allocated input 3 3 If you selec...

Page 22: ...occurred at times when outputting content from an Apple MacBook Pro via a mini DisplayPort to a DVI adapter In order to allow the use of sources such as the MacBook Pro to display non HDCP protected...

Page 23: ...TER key button to complete the process The default setting is 115200 4 4 11 Control Lock Locks and unlocks the controls such as Web RS 232 TCP IP UDP and key button Control Lock Web Lock UnLock Data L...

Page 24: ...program for MATRIXPRO II DVI 16x16 The PC program provides a user friendly graphic interface alternative to key button input and command input operation Copy MPII DVIsetup exe file in any directories...

Page 25: ...elect baud rate The baud rate of your PC should be the same as the MATRIXPRO II DVI 16x16 baud rate 115200 is default For Ethernet control enter the IP address of the MATRIXPRO II DVI 16x16 and port n...

Page 26: ...ator Click Apply button to save it 5 1 4 Control Lock Mode Locks and unlocks the controls such as Web Data control RS 232 TCP IP and UDP and key button input Click Apply button to save it 5 1 5 Networ...

Page 27: ...l first and then click the input channels Click the Apply button to save settings Edit Data Mode is used to modify existing EDIDs or to make a new custom EDID This feature is recommended for advanced...

Page 28: ...to outputs 05 06 07 and 08 as shown in Fig 4 5 To connect one input to all outputs click All Link button and click desired input Then all of the outputs will be connected to the selected input To dis...

Page 29: ..._ User s Guide Rev 01 29 5 3 3 Output channel status Green LEDs above the output channel number indicate Hot Plug Detection HPD from display For example CH07 is connected to a display The connected ou...

Page 30: ...h the web browser and enter the IP address of current MATRIXPRO II DVI 16x16 into the URL address line For example 192 168 0 246 Fig 6 1 shows structure of Web control panel It controls input output c...

Page 31: ...of a string of ASCII codes and its basic structure is Command Delimiter Data Delimiter or or _ Data End Table 6 1 shows all commands and its brief descriptions Command Description LINK Input and Outp...

Page 32: ...akes input 1 connected to output 10 Reply LINK 01 10 LINK 1 03 04 7 Makes input 1 connected to output 3 and 4 to 7 Reply LINK 01 03 04 07 LINK 05 Makes input 5 connected to all outputs Reply LINK 05 L...

Page 33: ...m 00 to FF Reply NETPA AA BB CC DD EE FF NETPT 3000 Sets UDP port number data ranges from 0 to 65535 NETPT 3000 NET Requests current network setting Reply NETGW 192 168 001 001 NETIP 192 168 001 118 N...

Page 34: ...D OUT3_5 Output copy mode Copies EDID information of output 3 display and stores it in input port 5 Reply EDID 03OUT EDID Requests current EDID setting for all inputs Reply EDID 01OUT 02AUTO03OUT 16ED...

Page 35: ...115200BPS Table 7 7 Baud rate setting command examples 7 2 8 Control lock command Locks and unlocks the controls such as Web RS 232 TCP IP and UDP Requests open status of controls ASCII Description WL...

Page 36: ...36 8 Firmware update 1 Using a Windows XP based PC install the megaboot exe program provided on a CD 2 Click Open of File to be programmed in the Flash to select directory and file hex Format to be up...

Page 37: ...16 to a RS 232 Comm port on a PC using the supplied download cable RJ1 1 to D Sub 9Pin cable 4 Select Comm port to select communication port of PC for RS 232 communication with MATRIXPRO II DVI 16x16...

Page 38: ...I DVI 16x16 Router ________________________________________________________________________ User s Guide Rev 01 38 8 After 1 to 2 minutes and All Done message will be shown Then the firmware upload is...

Page 39: ...DVI 16x16 Router ________________________________________________________________________ User s Guide Rev 01 39 9 Close the MegaBoot exe program and reboot MATRIXPRO II DVI 16x16 to run it under the...

Page 40: ...required protection For proper implementation products that are compatible with the HDCP format require a secure connection to a compliant display such as a projector or monitor In applications in wh...

Page 41: ...nk DVI digital formats up to 165 Mhz per DVI 1 0 specification Reference and Monitor Formats all single link DVI digital formats up to 165 Mhz per DVI 1 0 specification Physical and Electrical Specifi...

Page 42: ...htning strikes abuse drop crush and or other unusual damages The customer shall pay shipping charges when unit is returned for repair Barco will cover shipping charges for return shipments to customer...

Page 43: ...bsite www barco com Sales Contact Direct 916 859 2505 Toll Free 888 414 7226 E mail folsomsales barco com Barco N V Noordlaan 5 8520 Kuurne BELGIUM Telephone 32 56 36 82 11 Fax 32 56 35 16 51 Website...

Reviews: