background image

A Crane Co. Company

BARNES

®

INSTALLATION and OPERATION MANUAL

Submersible Sewage Non-Clog Pumps

IMPORTANT! 

Read all instructions in this manual before operating pump.

 

As a result of Crane Pumps & Systems, Inc., constant product improvement program,

 

product changes may occur. As such Crane Pumps & Systems reserves the right to 

 

change product without prior written notifi cation.

420 Third Street   

83 West Drive, Brampton

Piqua, Ohio 45356 

Ontario, Canada L6T 2J6

Phone: (937) 778-8947 

Phone: (905) 457-6223

Fax: (937) 773-7157 

Fax: (905) 457-2650

www.cranepumps.com

Form No. 133406-Rev. D

Series: 

4SE-L, 1.9 & 2.8HP

 

 

1150RPM, 60Hz

Series: 

4SE-L, 2.8, 3.7 & 5HP

 

 

1750RPM, 60Hz

Series: 

4SE-L, 5HP

 

 

3450RPM, 60Hz

Summary of Contents for 4SE-L series

Page 1: ...program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Brampton Piqua Ohio 45356 Ontario...

Page 2: ...RPM Fig 13 17 PARTS LIST 18 20 CROSS SECTION 3450RPM Fig 14 21 EXPLODED VIEW 3450RPM Fig 15 22 PARTS LIST 23 24 WARRANTY 25 RETURNED GOODS POLICY 26 WARRANTY REGISTRATION 26 SPECIAL TOOLS AND EQUIPMEN...

Page 3: ...OT insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safet...

Page 4: ...Magnet Wire Class F on selected models Service Factor 1 15 SINGLE PHASE Permanent Split Capacitor PSC Includes overload protection in motor THREE PHASE 200 230 460 60Hz is Tri voltage motor 575V Requ...

Page 5: ...Filled Squirrel Cage Induction Winding Class B Class H Rated Magnet Wire Service Factor 1 15 THREE PHASE Dual voltage 230 460 motor 575V Requires overload protection to be included in control panel VF...

Page 6: ...n or basin shall be vented in accordance with local plumbing codes This pump is designed to pump sewage effluent or other nonexplosive or noncorrosive wastewater and shall NOT be installed in location...

Page 7: ...ads for continuity resistance no moisture and the junction box control box for moisture content The above situations may induce a false signal in the moisture detecting circuit If none of the above te...

Page 8: ...0 35 9 42 7 12 4 SOOW SOW 68 17 4 7 64 1 77 4SE2844L 2 8 460 3 60 1750 G B 4 0 21 3 14 4 SOOW SOW 57 14 5 10 64 4SE2854L 2 8 575 3 60 1750 F B 3 2 14 4 14 4 SOOW SOW 57 14 5 4 68 16 63 4SE3724L 3 7 23...

Page 9: ...l as per section F 1 4 F 1 3 Pressure Test Pumps that have had the oil drained from the Motor Housing Apply pipe sealant to pressure gauge assembly and tighten into pipe plug hole See Figure 2 Pressur...

Page 10: ...n oil from motor as outlined in paragraph F 1 2 Disassemble volute and impeller as outlined in paragraph F 2 1 and disassemble shaft seal as outlined in paragraph F 4 1 Position unit upright using blo...

Page 11: ...12 using connectors 11 and wire assemblies 12 as required Do not use wire nuts Slip motor leads and ground wire through fiberglass sleeve 10 Lower motor housing 2 down onto bearing bracket 21 while al...

Page 12: ...nge seal components replace the entire shaft seal 46 F 4 2 Reassembly Diaphragm At reassembly make sure the bulge and molded in part number of diaphragm 32 is facing the seal plate 25 With diaphragm 3...

Page 13: ...aragraph F 1 4 SECTION G REPLACEMENT PARTS G 1 ORDERING REPLACEMENT PARTS When ordering replacement parts ALWAYS furnish the follow ing information 1 Pump serial number and date code Paragraph G 4 2 P...

Page 14: ...14 FIGURE 11...

Page 15: ...security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always ood...

Page 16: ...16 61 60 52 53 15 3 26 34 35 19 20 24 28 9 44 43 47 30 29 58 59 2 1 46 33 56 55 54 57 10 27 18 16 14 39 25 21 42 32 48 49 OIL LEVEL 49 50 31 51 FIGURE 12 4SE 1150 1750RPM Pump Series...

Page 17: ...4 35 48 28 42 58 59 51 39 49 49 25 32 43 9 44 46 27 18 31 21 42 14 16 5 6 49 4 53 52 57 56 7 54 55 6 4 49 5 50 2 20 19 15 3 10 1 33 30 29 47 60 61 11 12 CONNECTOR ASSY 50 50 FIGURE 13 4SE 1150 1750RPM...

Page 18: ...se 4 6 026322 Lock washer 5 16 SS 5 2 014270 3 8 NPT Pipe Plug ZP 6 6 1 156 1 HXHD Cap Screw 5 16 18 x 1 LG SS 7 1 103503 Handle SS 9 4 20 13 1 1 4 Lock washer SS 10 2 625 02117 Fiberglass Sleeve 230V...

Page 19: ...D Cap Screw 1 4 20 x 1 LG SS 42 2 033730 t Square Ring Buna N 43 1 022879 Diaphragm Clamp Ring AI 44 4 002204 HXHD Cap Screw 1 4 20 x 1 LG Steel 4 1 7 1 HXHD Cap Screw 1 4 20 x 1 LG SS 46 1 064434 t S...

Page 20: ...103739XL 103586 4SE5044L 103742XC 103742XF 103742XL 103583 4SE5054L 103742XC 103742XF 103742XL 103583 MODEL NUMBER 30 FT SENSOR 50 FT SENSOR 100 FT SENSOR TERMINAL BLOCK SENSOR 4SE1926L 113288XC 1132...

Page 21: ...21 4SE L 3450RPM Pump Series FIGURE 14...

Page 22: ...2 63 26 24 34 35 28 42 58 59 51 39 25 32 43 9 44 46 27 18 21 42 14 16 5 47 29 30 33 1 12 10 11 60 61 19 20 2 5 7 4 6 57 56 55 54 53 52 4 6 49 49 50 50 31 49 49 48 49 50 FIGURE 15 4SE L 3450RPM Pump Se...

Page 23: ...105149A Jumper Wire 230V 3 Phase 13 150 oz 029034 Oil Motor Housing 40 oz 029034 Oil Seal Cavity 14 2 038156 Machine Screw 6 32 x 3 8 LG ZP 16 1 133403B Moisture Sensor Wire Red 1 133403A Moisture Sen...

Page 24: ...Cord Terminal Block 57 2 2 31051 224 O Ring Buna N 58 2 026989 Shim 005 Use as required 59 2 028120 Shim 010 Use as required 60 2 016660 Self Tap Screw 8 32 x 3 8 LG SS 61 1 105111 Ground Wire Sensor...

Page 25: ...s between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FR...

Page 26: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...