TL205
INSTALLATION INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
INSTALLATION INSTRUCTIONS
READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY
•
DISCONNECT AC POWER SUPPLY BEFORE SERVICING.
•
Installation and servicing of this equipment should be performed by qualified service personnel only.
•
Ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.
•
Do not mount near gas or electrical heaters.
•
Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by
unauthorized personnel.
•
The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Any
modification or use of non-original components will void the warranty and product liability.
•
Do not use this equipment for other than intended use.
800 533.3948
•
www.barronltg.com
1
20070044 REV 2 - 12/13
1. Mount housing assembly to desired bracket using the provided mounting bolt. An optional mounting yoke or pole
tenon mount are also available.
2. Care should be taken when mounting fixture not to pinch leads.
3. Open “Ballast Housing” cover by loosening (4) Phillips captive screws.
4. Electrical connections should be made inside fixture. Cap all unused leads to prevent shorting. This fixture is pre-wired
for 277 volt; make sure supply line voltage is 277 volt. For alternate line voltage select proper ballast lead to match
your line voltage.
a. Connect the line fixture lead to the black supply lead.
b. Connect the common fixture lead to the white supply lead
c. Connect the ground lead form the service to the green grounding screw.
5. Use approved connectors to connect fixture leads to supply leads and make wire splices inside fixture. Use rated
connectors of 600V 150°C, UL listed.
6. Close “Ballast Housing” cover by tightening (4) Phillips captive screws, ensure wires are not pinched.