Installation Instruction
Xbeam LTE EX Antenna
BARTEC
TECHNOR AS
Vestre Svanholmen 24
4313 SANDNES
NORWAY
Tel.: +47 51 844100
Fax: +47 51 844101
sales@bartec-technor.no
www.bartec-technor.no
Reservation
Technical data subject to change without notice. Changes, errors and
misprints may not be used as a basis for any claim for damages.
EN 1/4
Type Xbeam LTE EX
Explosion protection
Technical data
ATEX
Ex type of protection
0470
II 2 G
Ex eb mb IIC, IIB, IIA T6 Gb
II 2 D
Ex tb IIIC T85°C Db, IP66 / IP67
EU Type Examination Certificate
CML 22ATEX3353X
IECEx
Ex type of protection
Ex eb mb IIC, IIB, IIA T6 Gb
Ex tb IIIC T85°C Db, IP66 / IP67
Certificate of Conformity
IECEx CML 22.0050X
Ambient temperature range
-40°C ≤ Ta ≤ +60°C
Ingress Protection
IP66 / IP67
Supply data
U
n
:
Max 20 Vpp
P :
Frequency:
IIC: 2 W
IIB: 3,5 W
IIA: 6 W
0,5 – 6 GHz
Production year
As stated on the marking label of the product
Serial number
As stated on the marking label of the product
Marking label
Please refer to notes on the marking label
Text label
‘POTENTIAL ELECTROSTATIC
CHARGING HAZARD - SEE
INSTRUCTIONS’
Depending on the technical execution
24
05
2-
5
v1
In
st
al
la
tio
n
In
st
ru
ct
io
ns
X
b
ea
m
L
T
E
E
X
Note to instructions
When working in hazardous areas, the safety of
personnel and equipment depends on
compliance with the relevant safety regulations.
Personnel in charge of installation and
maintenance bear a special responsibility and
must have required competence and knowledge
of the applicable rules and regulations.
The instructions provide a summary of the most
important safety measures and must be read by
all personnel to ensure correct handling of the
product.
The instructions have to be kept for future
reference and must be available throughout the
lifetime of the product.
Description
The Xbeam LTE EX is an ATEX and IECEx
approved RF antenna for creating wireless
networks and wireless telemetry systems in
hazardous area. The antenna is optimized for
use
in
steel
and
concrete
structure
environments where multipath effects and
reflections are present.
The
Xbeam LTE EX
is an ideal solution if the
access point is placed in safe zone, and the
antenna shall provide coverage in hazardous
areas. Due to power loss in the Coax cables, the
cable length should not exceed 30 m.
The antenna must be mounted by its base using
the 4 off Ø11 holes for this. The base has to be
connected to earth. The antenna is constructed
with a permanently connected, unterminated
coax cable that must be properly protected and
the connection must be carried out in an
appropriate certified Ex-e or Ex-d enclosure, or
in safe area. Additional clamping of the cable
shall be installed, to ensure that pulling and
twisting is not transferred to the terminations
inside the antenna.
Other applicable documents
Xbeam LTE EX
Datasheet.
The retention of these documents is mandatory.
Increased Safety Product, BARTEC
Technor Xbeam LTE EX
Read these installation instructions carefully
before mounting, installation, commissioning
and maintenance.
Notes on the marking label
Specific conditions of use which are important
for the installation, the use or the maintenance
of the product will be unabbreviated adopted into
this manual.
In case of loss always mention the type and
serial/batch number at BARTEC office.