background image

Issue 2: 2016          

                SERVICE & GUARANTEE

 

 

The  quality  standards  applied  to  the  inspection,  test 

and calibration of AUDIT Ultrasonic Thickness Gauges 

are in accordance with 

ISO 9001: 2008

 quality control 

procedures  and  all  measurements  are  traceable  to 

national standards. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 20

 

 

 

Issue 2: 2016                                                

INTRODUCTION

 

      

 

 

                   

 

1.   INTRODUCTION.

 

 

The AUDIT 207 is  a  Precision Ultrasonic Thickness 

handheld gauge for fast and accurate  metric or Imperial  

measurement of the thickness of a wide range of metals 

and plastics materials, performed with access to only one 

side of the material being measured. 

 

This  handbook  describes  the  instrument  and  how  to 

use it to its best advantage. 

 

1.1  Cautionary information.

 

 

The AUDIT 207 is intended to satisfy  a wide range of 

applications, including corrosion monitoring. 

However, the user should be aware that corrosion in a 

pipeline or vessel is not uniform and thickness readings 

taken  on  a  sampling  basis,  example    testing  to  a  grid 

pattern  may  not  indicate  the  most  severely  corroded 

areas.  

 

It  is  therefore  important  that  inspection  schedules 

should be developed by competent engineers and that 

measurement  of  the  integrity  of  a  pipeline  or  vessel 

should  take  account  of  this  factor.    In  addition,  users 

should  be  properly  trained  in  the  use  of  ultrasonic 

thickness gauges and be made aware of the limitations 

of the equipment and the proposed testing schedule. 

 

 

Page  2 

Issue 2: 2016                                                         

INDEX   

 

     

       

Page

                          

 

 

1. 

INTRODUCTION

 

 2 

1.1 

Cautionary information 

 2 

1.2 

Standard Schedule of Equipment 

 3 

1.3 

Optional Equipment 

 4 

2. 

TECHNICAL  SPECIFICATION

 

 4 

2.1 

Thickness Range 

 4 

2.2 

Accuracy & Calibration 

 4 

2.3 

Power Supply 

 4 

2.4 

Temperature Range 

 5 

2.5 

Environmental Protection 

 5 

2.6 

Electromagnetic Compatibility 

 5 

3. 

PRINCIPLE OF OPERATION

 

 6 

4. 

DIRECTIONS FOR USE

 

 7 

4.1 

Preparation 

 7 

4.2 

Transducer ZERU Calibration 

 7 

4.3 

Thickness Measurement 

 8 

4.4 

Two point Calibration 

 8 

4.5 

Metric – Imperial Mode change 

 9 

4.6  

Scan Mode 

 9 

4.7 

Fit Batteries 

10 

4.8 

Other Indications During Use 

10 

4.9 

Limitations 

10 

5. 

OPERATION AND APPLICATION INFORMATION

  

  11 

5.1 

Basic Technique 

11 

5.2 

Effect of Surface and Hot Conditions 

12 

5.3 

Painted Parts 

13 

5.4 

Couplant 

14 

5.5 

Transducer Wear 

14 

6. 

CARE & MAINTENANCE

 

15 

7. 

HEALTH AND SAFETY

 

 

16 

8. 

SERVICE AND GUARANTEE OF EQUIPMENT

 

17 

8.1 

Guarantee 

17 

8.2  

How to make a Guarantee Claim 

18 

8.3 

Service Repairs and Maintenance 

19 

8.4 

Certification 

20 

 

 

 

Page 1 

 

 

Issue 2: 2016    

             

SERVICE & MAINTENANCE

 

 

8.3  Service Repairs and Maintenance

 

 

Repairs  not  covered  by  the  guarantee  or  carried  out 

after the guarantee period will be charged at the current 

hourly service rate, plus the cost of materials. 

Goods  for  repair  must  be  sent  at  the  Purchaser's 

expense  and  be  accompanied  by  the  Purchaser's 

written order describing the defect and authorising the 

company to invoice the purchaser for labour, materials 

and return delivery costs. 

 

No guarantee or service work will be undertaken until a 

written order is received. 

 

Baugh  &  Weedon  undertakes  to  offer  repair  and 

maintenance  services  to  the  AUDIT  207  thickness 

gauge for a period of not less than five (5) years from 

the date of original dispatch. 

The Company cannot make any such undertaking after 

that  period  although  it  will  use  its  best  endeavours  in 

every case. 

 

 

 

 

 

 

 

 

 

Page 19 

Summary of Contents for Audit 207

Page 1: ...4 2 TECHNICAL SPECIFICATION 4 2 1 Thickness Range 4 2 2 Accuracy Calibration 4 2 3 Power Supply 4 2 4 Temperature Range 5 2 5 Environmental Protection 5 2 6 Electromagnetic Compatibility 5 3 PRINCIPLE OF OPERATION 6 4 DIRECTIONS FOR USE 7 4 1 Preparation 7 4 2 Transducer ZERU Calibration 7 4 3 Thickness Measurement 8 4 4 Two point Calibration 8 4 5 Metric Imperial Mode change 9 4 6 Scan Mode 9 4 7...

Page 2: ...acy Calibration Velocity Range 1200m s to 10000ms 0 0492 in µs to 0 3930in µs Resolution 0 01mm 0 001 Accuracy 0 01millimeters 0 001inches Material dependent 2 3 Power Supply Source 2 x LR6 AA Alkaline Batteries or rechargeable equivalents Battery life 50 hours continuous alkaline dry batteries Auto power off timer 5 Minutes Page 4 Issue 2 2016 INTRODUCTION Before using the equipment operators sho...

Page 3: ... reflected back from the far surface As the velocity at which the sound travels is constant for a given material the thickness can be computed and displayed Thickness readings are held for 5 Minutes after the probe is removed from the work piece Page 6 Issue 2 2016 TECHNICAL SPECIFICATION Backlight is operated by the UNIT key selectable on off Low battery is indicated by the battery symbol located...

Page 4: ...highest known thickness of the test part 2 Press CAL key until set thickness is displayed using up down keys to display the known thickness Page 8 Issue 2 2016 DIRECTION FOR USE The velocity used for calculation is that of steel It is a simple matter to convert the reading for other common materials by using the appropriate Velocity Through the CAL key operation Fit batteries see section 4 4 Conne...

Page 5: ...ce of the material under test it is possible due to the composition and or grain structure of some materials plastics cast iron etc that limitations to the thickness range is possible as the material is too attenuative for the ultrasound to penetrate Page 10 Issue 2 2016 PREPARATION 3 Press ZERO key 4 Place the probe on the thinner known thickness of the test part followed by the CAL key 2 nd thic...

Page 6: ... adjust up down keys to display the known thickness 3 Press ZERO key 4 Place the probe on thinner known section followed by the CAL key 2 nd thickness is displayed using up down keys set this thickness displayed to match thinner section press CAL key Velocity will automatically enter measurement screen The Audit 207 is now ready to take readings AUDIT 207 Two Point Calibration 1 Place the probe on...

Page 7: ... incorporated on 13 11 2006 in the United Kingdom Company Registration Number 05996485 VAT Number GB583598190 ALPINE C O M P O N E N T S Postal Address Alpine Components Ltd Innovation Centre Highfield Drive Churchfields St Leonards on Sea TN38 9UH United Kingdom Telephone 01424 858118 Website Address www alpine components co uk ...

Reviews: