Issue 2: 2016
SERVICE & GUARANTEE
The quality standards applied to the inspection, test
and calibration of AUDIT Ultrasonic Thickness Gauges
are in accordance with
ISO 9001: 2008
quality control
procedures and all measurements are traceable to
national standards.
Page 20
Issue 2: 2016
INTRODUCTION
1. INTRODUCTION.
The AUDIT 207 is a Precision Ultrasonic Thickness
handheld gauge for fast and accurate metric or Imperial
measurement of the thickness of a wide range of metals
and plastics materials, performed with access to only one
side of the material being measured.
This handbook describes the instrument and how to
use it to its best advantage.
1.1 Cautionary information.
The AUDIT 207 is intended to satisfy a wide range of
applications, including corrosion monitoring.
However, the user should be aware that corrosion in a
pipeline or vessel is not uniform and thickness readings
taken on a sampling basis, example testing to a grid
pattern may not indicate the most severely corroded
areas.
It is therefore important that inspection schedules
should be developed by competent engineers and that
measurement of the integrity of a pipeline or vessel
should take account of this factor. In addition, users
should be properly trained in the use of ultrasonic
thickness gauges and be made aware of the limitations
of the equipment and the proposed testing schedule.
Page 2
Issue 2: 2016
INDEX
Page
1.
INTRODUCTION
2
1.1
Cautionary information
2
1.2
Standard Schedule of Equipment
3
1.3
Optional Equipment
4
2.
TECHNICAL SPECIFICATION
4
2.1
Thickness Range
4
2.2
Accuracy & Calibration
4
2.3
Power Supply
4
2.4
Temperature Range
5
2.5
Environmental Protection
5
2.6
Electromagnetic Compatibility
5
3.
PRINCIPLE OF OPERATION
6
4.
DIRECTIONS FOR USE
7
4.1
Preparation
7
4.2
Transducer ZERU Calibration
7
4.3
Thickness Measurement
8
4.4
Two point Calibration
8
4.5
Metric – Imperial Mode change
9
4.6
Scan Mode
9
4.7
Fit Batteries
10
4.8
Other Indications During Use
10
4.9
Limitations
10
5.
OPERATION AND APPLICATION INFORMATION
11
5.1
Basic Technique
11
5.2
Effect of Surface and Hot Conditions
12
5.3
Painted Parts
13
5.4
Couplant
14
5.5
Transducer Wear
14
6.
CARE & MAINTENANCE
15
7.
HEALTH AND SAFETY
16
8.
SERVICE AND GUARANTEE OF EQUIPMENT
17
8.1
Guarantee
17
8.2
How to make a Guarantee Claim
18
8.3
Service Repairs and Maintenance
19
8.4
Certification
20
Page 1
Issue 2: 2016
SERVICE & MAINTENANCE
8.3 Service Repairs and Maintenance
Repairs not covered by the guarantee or carried out
after the guarantee period will be charged at the current
hourly service rate, plus the cost of materials.
Goods for repair must be sent at the Purchaser's
expense and be accompanied by the Purchaser's
written order describing the defect and authorising the
company to invoice the purchaser for labour, materials
and return delivery costs.
No guarantee or service work will be undertaken until a
written order is received.
Baugh & Weedon undertakes to offer repair and
maintenance services to the AUDIT 207 thickness
gauge for a period of not less than five (5) years from
the date of original dispatch.
The Company cannot make any such undertaking after
that period although it will use its best endeavours in
every case.
Page 19