background image

Ovi-Scan 

Your animal imaging partner

Instruction manual

Ovi-Scan manual v.3.indd   1

13/07/2012   16:44

Summary of Contents for Ovi-Scan

Page 1: ...Ovi Scan Your animal imaging partner Instruction manual Ovi Scan manual v 3 indd 1 13 07 2012 16 44 ...

Page 2: ...tal age 12 2 2 6 Drafting 13 2 2 7 RFID 14 2 2 8 Modes 14 3 Module removal refitting 15 4 Portable power sources 16 4 1 12 volt DC source 16 5 Duo Scan option 17 5 1 Mode control 17 6 Ovi Scan console 18 Appendix A Safety principles 19 Appendix B Safety devices 20 Appendix C Gel powder mix 21 Appendix D Service and maintenance 23 Appendix E Key to scanner connectors 25 Service centres 26 Accessori...

Page 3: ... providing ultrasound imaging equipment for animal husbandry applications we understand the importance of having reliable equipment All BCF products are designed and manufactured to withstand the environments in which they are going to be used However should you experience any problems with your Ovi Scan BCF Technology service engineers will be available to provide rapid service support and ensure...

Page 4: ...se only the BCF supplied charger This charger is matched to the battery capacity and will ensure long life and continued safety Higher charge rates from unsuitable chargers may lead to hazards from fire or battery leakage in addition to reducing battery life Although the Ovi Scan runs from a low voltage source dangerous voltages are generated within the unit For this reason no attempt should be ma...

Page 5: ... of brightness and contrast and gives a comparison of grey intensity for the ultrasound picture 4 The real time ultrasound sector can be displayed either as an inverted image or non inverted image As the range is altered the speed of the probe varies to provide the best quality image The smaller the range the faster the probe rotates 5 The current function of the soft keys is displayed along the b...

Page 6: ...ttery cable to connector K on the rear panel of the module Rotate connector until the notch on the power connector aligns with the key on the console then tighten the outer ring to secure Press and hold the POWER button L on the front panel until the system beeps The green DC POWER light M should be illuminated and the console will now perform a system initialisation If the probe is connected it w...

Page 7: ...reeze the image a long press more than 2 seconds will power the system down 2 2 Menu system All functions of the Ovi Scan are set using menus selected using the soft keys below the screen on the pull out module Soft Key 1 on the left is used to cycle through the menus the other keys are then used to access sub menus and settings The system defaults to the TALLY menu on power up and cycles through ...

Page 8: ...ore use Note The Tally controller functions regardless of which menu is currently displayed A Run Tot To toggle between running tally and total tally press soft key 2 RUN TOT When displaying total tally counting is not possible Return to running tally to continue counting B Add Clear To reset the running tally and add it to the total press soft key 3 ADD CLEAR Before starting the next flock take a...

Page 9: ...e the arrow keys at soft keys 3 and 4 The grey bar may be used as a guide in setting these controls when the controls are set to suit the lighting conditions individual blocks should be discernible within both the lighter and darker extremes of the grey bar The current brightness and contrast settings are displayed values between 1 and 16 Ovi Scan manual v 3 indd 9 13 07 2012 16 44 ...

Page 10: ...y shifts the range up pressing 3 0 simultaneously shifts the range down B Gain When GAIN is displayed above soft key 2 the arrow keys can be used to adjust the gain within the range 1 10 This is typically set to 6 so that the background noise is just visible but can be used to alter echo levels as required C Power When POWER is displayed above soft key 2 the arrow keys can be used to adjust the po...

Page 11: ...nge the scan direction press soft key 3 REVERSE Press REVERSE again to return to the original direction C Freeze A complete ultrasound image frame can be held by pressing soft key 4 FREEZE To return to real time ultrasound press FREEZE key again When the image is frozen no ultrasound pulses are transmitted In Freeze mode the user can cycle through the menus as normal but only the Foetal Age and Di...

Page 12: ...s between days weeks or millimetres A Cattle The cattle trunk diameter indicators are displayed in five sizes 67 days 77 days 91 days 105 days and 119 days The crown rump length is displayed in one size of 63 days Note Cattle indicators are only available on ranges of 16 cm 25 cm B Sheep The sheep indicators are available in six sizes 56 63 70 77 84 and 91 days 56 77 days are displayed as short li...

Page 13: ...h delays of 100 mS 300 mS and 500 mS If one of the gates is selected then pressing soft key 4 will cycle through the gate options on off or disabled Example To set up tally 1 for a 300 mS delay with gate 1 on gate 2 off Press soft key 1 until the drafting menu is visible Press soft key 2 until tally 1 is visible in the 2nd column Press soft key 3 until Delay is visible in the 3rd column Press soft...

Page 14: ...nd Duo Scan modes A OVI STORE Pressing soft key 2 will store the current depth frequency gain and power settings as well as the scan orientation direction settings brightness contrast and all foetal aging indicators B DUO STORE Pressing soft key 3 will store the current depth frequency gain and power settings as well as the scan orientation direction settings and all foetal aging indicators for us...

Page 15: ...canner Duo Scan To remove the module Ensure that the power is switched off Release the latches on both sides of the console Withdraw the module To refit the module Ensure that the power is switched off Gently insert the module Once the module is fully home both latches should be closed Ovi Scan manual v 3 indd 15 13 07 2012 16 44 ...

Page 16: ...hould not be connected to any source with a voltage greater than that of a 12 volts vehicle battery or damage may result Connecting the battery in reverse polarity may damage the instrument and the battery source To avoid the risk of explosion do not short circuit the positive and negative terminals of the battery It is recommended that the supply leads from the battery should have in line overloa...

Page 17: ...on is displayed on screen only the greyscale bar and ultrasound image are displayed In Duo Scan mode a battery capacity and voltage reading are displayed in the lower corners of the display The menu disappears after approximately 7 seconds leaving only the scan voltage and battery capacity displayed 5 1 Mode control All possible modes are stepped through by pressing soft key 1 Mode The default mod...

Page 18: ...he console defaults to RF channel 1 and each subsequent press will cycle through the 4 available channels The selected RF channel is fed out through the Ext Vid connector N Button 3 Pressing button 3 on the tally controller will select the digital video input this is the input used by the Duo Scan This allows the Duo Scan output to be viewed on the console even if correct communications have not b...

Page 19: ...s at which the RCD will then cut off isolating the equipment at zero potential If no RCD is fitted then the mains fuse would blow however this takes significantly longer depending on fuse rating and can result in shock voltages of much higher values unless an isolating step down transformer with a centre tap is used in which case the maximum voltage present would be 55 volts A small voltage may ex...

Page 20: ...rent for an RCD is 30 milliamps mA An RCD should be tested by stimulating an earth fault condition which is independent of any test facility within the device The test push should be used at regular intervals in order to test the function of the tripping mechanism It does not test if the device will operate in the event of an earth fault Anti Surge adapter The function of the anti surge adapter is...

Page 21: ...nt is strongly hydrophilic and mixing can present difficulties since a very small amount of water will readily disperse through a large quantity of powder forming a hard lump Left alone the lump will slowly disperse and beyond a certain point dilution becomes very easy Continuous stirring of the water and the slow addition of the gel powder will produce a suitable solution 3 Generally speaking the...

Page 22: ...itted with the paint stirring tool are excellent for the mixing of large volumes of gel Note When using electrically powered mixers it is important to ensure the electrical equipment is in good condition The appliance should not be used with damaged cables insecure clamps or inadequate earthing connections where these are required This is particularly applicable if mixing is carried out on site Ov...

Page 23: ...s flush with alcohol and leave to drain hanging downwards Never force a connector if it will not go together easily Debris may collect between the pins and can be carefully removed with a small screwdriver Be very careful to avoid anything getting into the gold plated connector inserts this may cause damage and some of these are expensive to replace Do not knock or scrape the transducer window thi...

Page 24: ... Pay extra attention close to connectors and joints If damage is found it is imperative to have repairs carried out immediately to avoid further damage or risk of electric shock The console display is easily marked or damaged take care to avoid sharp or pointed objects near the display Do not use abrasive cleaners on the display computer screen wipes or isopropyl alcohol are ideal for cleaning the...

Page 25: ...25 Appendix E Key to scanner connectors Console rear panel Duo Scan and console front panels Ovi Scan manual v 3 indd 25 13 07 2012 16 44 ...

Page 26: ...gy com In Ireland BCF Technology Ltd Unit 2 Quayside Business Park Mill Street Dundalk Co Louth Ireland T 353 0 42 932 0070 ireland bcftechnology com www bcftechnology com In North America BCF Technology USA Ltd LLC 2625 Highway 14 West Suite K Rochester Minnesota 55901 T 507 529 8200 T 800 210 9665 F 507 529 8205 contact bcftechnology com www bcftechnology com In Australasia BCF Ultrasound Austra...

Page 27: ...27 Accessories BUG BCF Universal Goggles DC lead Carry bag Tally counter Gel feed system Video cable Radial probe rectal Axial probe Batteries and charger Ovi Scan manual v 3 indd 27 13 07 2012 16 44 ...

Page 28: ...echnology Ltd July 2012 For further information on care and maintenance of the Ovi Scan please visit the Customer support section of the BCF website www bcftechnology com Ovi Scan manual v 3 indd 28 13 07 2012 16 44 ...

Reviews: