background image

RIM-EXIT ELECTRIC STRIKE

10STRIKERE34

10STRIKERE34

©BEA

 | Original Instructions

75.5012.01 RIM EXIT ELECTRIC STRIKE 

20210121

 

Page 1 of 2

Rim-exit electric strike for access doors

with 

½

” and 

¾

” housing thickness

ENGLISH

‰

Shut off all power going to header before attempting any wiring procedures.

‰

Maintain a clean and safe environment when working in public areas.

‰

Constantly be aware of pedestrian traffic around the door area.

‰

Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.

‰

ESD (electrostatic discharge)

:  Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board,

ensure you dissipate your body’s ESD charge.

‰

Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause
damage to equipment.

‰

Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.

‰

DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA,
Inc. Unauthorized disassembly or repair:

1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.

½” Strike

(10STRIKEREV12)

¾” Strike

(10STRIKEREV34)

DESCRIPTION

GENERAL SAFETY

UL294 & UL1034 REQUIREMENTS

Visit website for available 

languages of this document.

!

CAUTION

Operating voltage

12 or 24 VDC

Current draw

540mA (12 VDC)
270mA (24 VDC)

Operating temperature

14 – 120 °F (-10 – 49 °C)

Humidity

0 – 85% non-condensing

Static strength

1500 lbs (680kg)

Dynamic strength

70 ft-lbs

Endurance

250,000 cycles (UL-tested)
1,000,000 cycles (factory-tested)

Lock mode

field selectable fail-safe or fail-secure

Performance level

destructive attack: level I
line security: level I
standby power: level I
endurance: level IV

Material (strike body)

brushed stainless steel (US32D)

Frame application

metal / wood

Latch throw  
(housing thickness)

¾” or ½”

Specifications are subject to change without prior notice.

All values measured in specific conditions.

TECHNICAL SPECIFICATIONS

‰

Indoor use only.

‰

Wiring methods shall be in accordance with NFPA70.

‰

10STRIKEREV is intended to be used with UL-listed, rim type, fire exit hardware, Von Duprin LLC, Model 99-F.

‰

10STRIKEREV shall not installed in the fail-secure mode unless permitted by the local Authority Having Jurisdiction (AHJ), and shall not impair panic hardware
operation.

‰

Remove the “Listed Fire Rated Hardware” label if the 10STRIKEREV is used in the fail-safe operation.  Using these strikes in fail-safe operation negates the
fire rating.  10STRIKEREV is fire rated in fail-secure operation only.

‰

10STRIKEREV are access control unit accessories intended to be controlled by an access contol system.  The purpose of access control systems is to provide a
means for controlling lock and unlocking external and internal doors of a premise.

Reviews: