background image

SIZE:

DRAWN BY:

TITLE: MC-LINX2 WITH 3 or 4

DOOR INTERLOCK

A

NOTES:
1.) Door Position Switch (DPS) shall close when it's respective door closes.
2.) If only a 3 door interlock is desired ensure to insert a jumper into input 4 on

MCLinx2 (#2)

100 ENTERPRISE DRIVE
PITTSBURGH, PA  15275
PHONE: (412) 249-4100
FAX:       (412) 249-4101
EMAIL:   www.beasensors.com

REV BY:

JED

JED

80.0249.00

SCALE:

DATE:

NONE

18 DEC., 2006

PART NO:

SHEET
1 OF 1

MC-LINX2

# 2

1

2

3

4

WET

OUTPUT

A

B

POWER

OUTPUT OPTION

SETUP

INPUT

5

12 to 24 VAC/VDC
+/- 10%

Input 3 is the door position switch
for Input 1 (Door 3).Input 4 is the door
position switch for input 2 (Door 4) if used.
Switch is closed when door is closed.

0

RELAY COIL

PUSH

PLATE

1

PUSH

PLATE

2

MC-LINX2

# 1

1

2

3

4

WET

OUTPUT

A

B

POWER

OUTPUT OPTION

SETUP

INPUT

5

12 to 24 VAC/VDC
+/- 10%

Input 1 and Input 2
are activation inputs
for Door 1 and Door 2
respectively

Inputs 3 and 4 are for the door position
switch for Input 1 (Door 1) and
Input 2 (Door 2) respectively.
Switch is closed when door is closed.

0

Output A directly to Activation Circuit of
Door Control #1. Output B directly to
Activation Circuit of Door Control #2.

DOOR 3

DPS

DOOR 2

DPS

PUSH

PLATE

3

13

14

Omron Part #
MY4INDC24 or
MY4INAC24

9

12

1

4

5

8

11

3

7

5

10

2

6

DOOR 1

DPS

Socket #
PTF14AE

IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM

DOOR 4

DPS

PUSH

PLATE

4

Output A directly to Activation Circuit of
Door Control #3. Output B directly to
Activation Circuit of Door Control #4 if used.

Input 1 and Input 2
are activation inputs
for Door 3 and Door 4
respectively

(SEE NOTE #2)

(SEE NOTE #1)

Reviews: