background image

IXIO-D CAN

1

4

5

6

3

9

2

8

7

1. 

radar antenna (narrow field)

2. 

radar antenna (wide field)

3. 

IR-curtain width adjustment

4. 

IR-lenses

5. 

cover

DESCRIPTION

6. 

main connectors 

7. 

push button

8. 

DIP-switch

9. 

IR-curtain angle adjustment knob

OPENING & SAFETY SENSOR 

FOR AUTOMATIC SLIDING DOORS 

User’s Guide for product version 0202 and higher
See product label for serial number

ACCESSORIES

BA: Bracket accessory

CA: Ceiling accessory

BEA Remote control

CDA: Curved door 

         accessory

(according to EN 16005 and DIN 18650,

including emergency exits)

RA: Rain accessory

ENGLISH

Summary of Contents for IXIO-D CAN

Page 1: ...utton 8 DIP switch 9 IR curtain angle adjustment knob OPENING SAFETY SENSOR FOR AUTOMATIC SLIDING DOORS User s Guide for product version 0202 and higher See product label for serial number ACCESSORIES BA Bracket accessory CA Ceiling accessory BEA Remote control CDA Curved door accessory according to EN 16005 and DIN 18650 including emergency exits RA Rain accessory ENGLISH ...

Page 2: ...e for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor Only trained and qualified personnel may install and setup the sensor The warranty is inva...

Page 3: ...nity 2 field size 9 immunity 2 The size of the detection field varies according to the mounting height of the sensor In emergency exits the full door width must be covered from 15 to 45 default 30 from 15 to 15 default 0 ENGLISH IXIO D CAN INSTALLATION GUIDE Plug the connector with the WHITE and GREEN wires on top towards the sensor cover GREEN BROWN POWER SUPPLY CAN HIGH CAN LOW YELLOW WHITE ...

Page 4: ... the inside door sensor and the inner curtain of the outside door sensor should always be smaller than 20 cm The distance to the door leaf depends therefore on the thickness of the door leaf The size of the detection field varies according to the mounting height and the settings of the sensor The full door width must be covered Mounting height Detection width 2 00 m 2 20 m 2 50 m 3 00 m 3 50 m 2 0...

Page 5: ...ROL Select parameter Select value Unlock Lock STANDARD standard in and outdoor installations factory values for immunities IR number and redirection You can choose one of the following presettings CRITICAL ENVIRONMENT critical installations due to surroundings or weather increased immunities 1 curtain SHOPPING STREET installations in narrow streets with pedestrian traffic increased immunities redi...

Page 6: ...5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s Always additionally adjust the arrow position on the sensor with a screwdriver 2 8 m 6 7 EN 16005 2 2 m 6 7 BS 7036 Sensors mounted close to each other need a different frequency motion motion or presence motion and presence opening output is active in case of 0 motion detection 1 motion or presence detection 2 motion and presence detection low normal high n...

Page 7: ...aunch an assisted setup and adjust the IR angle Replace sensor ORANGE LED flashes 6 x ORANGE LED flashes 7 x Faulty radar sensor output Replace sensor The internal test of the radar is disturbed Change radar field angle or antenna Launch a quick setup If orange LED flashes again replace sensor Check power supply and wiring ORANGE LED flashes 5 x The sensor receives too much IR energy ORANGE LED fl...

Page 8: ... cm x 5 cm typ Number of spots max 24 per curtain Number of curtains 2 CAN EN 12978 EN ISO 13849 1PL c CAT 2 under the condition that the door control system monitors the sensor at least once per door cycle IEC 61496 1 ESPE Type 2 EN 16005 Chapter 4 6 8 DIN 18650 1 Chapter 5 7 4 BS 7036 1 Chapter 8 1 Motion Min detection speed 5 cm s Microwave doppler radar Transmitter frequency 24 150 GHz Transmi...