The Electromagnetic Lock (Maglock) series is a surface-mounted, 
magnetic-lock assembly.  They are available in single- and dual-
lock varieties, various holding forces, and also avaible with or 
without built-in Door Status Switch (“DS” versions).  All models 
are designed for standard installation on most types of doors.

Door Position 

Switch 

ENGLISH

door configuration door status sensor

single

dual

with

without

10MAGLOCK3UL

10MAGLOCK3ULDS

10MAGLOCK6UL

10MAGLOCK6ULDS

1   Description

DESCRIPTION

10MAGLOCK3UL

10MAGLOCK3ULDS

10MAGLOCK6UL

10MAGLOCK6ULDS

Lock:

single

dual

Input Voltage:

12 or 24 VDC

12 or 24 VDC

Relay Rating:

1.0 A @ 24 VDC 

resistive

1.0 A @ 24 VDC 

resistive

Reed Switch Rating:

SPDT 0.5 amp @ 30 VAC/VDC 

resistive

SPDT 0.5 amp @ 30 VAC/VDC 

resistive

Power Consumption:

505 mA @ 12 VDC / 

260 mA @ 24 VDC

505 

×

 2 mA @ 12 VDC / 

260 

×

 2 mA @ 24 VDC

Dimensions:

9.84 x 1.65 x 1.02 in

250 x 42 x 26 mm

19.76 x 1.65 x 1.02 in

502 x 42 x 26 mm

Certification:

UL1034

UL1034

Operating Temperature:

14 – 131 °F (-10 – 55 °C)

14 – 131 °F (-10 – 55 °C)

Operating Humidity:

0 – 95%

0 – 95%

ATTENTION:  This product must be powered from a UL-listed, regulated, power-limited, power supply!

NOTE:  

The specifications listed above are for an indoor, dry, installation location.

2   Specifications

Summary of Contents for UL MAGLOCKS 600LB

Page 1: ... 1 Description DESCRIPTION 10MAGLOCK3UL 10MAGLOCK3ULDS 10MAGLOCK6UL 10MAGLOCK6ULDS Lock single dual Input Voltage 12 or 24 VDC 12 or 24 VDC Relay Rating 1 0 A 24 VDC resistive 1 0 A 24 VDC resistive Reed Switch Rating SPDT 0 5 amp 30 VAC VDC resistive SPDT 0 5 amp 30 VAC VDC resistive Power Consumption 505 mA 12 VDC 260 mA 24 VDC 505 2 mA 12 VDC 260 2 mA 24 VDC Dimensions 9 84 x 1 65 x 1 02 in 250...

Page 2: ...ocking efficiency 5 The maglock mounts rigidly to the door frame The armature plate mounts to the door with the hardware provided This allows the armature plate to pivot about its center to compensate for door wear and misalignment 5 Template use must take place with the door in its normally closed position 5 Add threadlocker to all screws before installing and firmly tighten screws 5 Install only...

Page 3: ...black plastic piece of the armature plate with the cover plate i e magnet must line up with the switch 6 Armature Plate Installation Hole For Guide Pin Hole For Nut Steel Washer Rubber Washer Steel Washer Armature Plate Nut Spacer Door Screw M8 35mm Guide Pin The product must be powered from a UL listed regulated power limited power supply If power switch is not wired between DC source voltage and...

Page 4: ...LIGHT COM REED SWITCH ON DOOR STATUS SENSOR SWITCH Switch changes state when door is open NO BEA Inc the sensor manufacturer cannot be held responsible for incorrect installations or incorrect adjustments of the sensor device therefore BEA Inc does not guarantee any use of the sensor device outside its intended purpose BEA Inc strongly recommends that installation and service technicians be AAADM ...

Reviews: