background image

Coin Box

EMS-58

Operating Manual

Beckmann GmbH © 2010

    Revision 2.0 – 29.10.10

Summary of Contents for EMS-58

Page 1: ...Coin Box EMS 58 Operating Manual Beckmann GmbH 2010 Revision 2 0 29 10 10 ...

Page 2: ...used by the buyer or other persons by accident misuse unauthorized changes repair or innovations of the product Furthermore the Beckmann GmbH is not liable for losses costs faults or consequential losses that may emerge by using this product The technical data correspond to the current conditions Misprints errors or changes reserved Beckmann GmbH Brandtstraße 1 33161 Hövelhof Fon 49 0 52 57 98 23 ...

Page 3: ...lling 6 4 2 Door opener optional 7 5 Programming 7 5 1 Procedure 7 5 2 Counter editing 7 5 3 Adjusting operating parameters 8 5 4 Switch parameter 8 5 5 Parameter overview 8 6 Technical data 9 7 Electronic Coin Selector 9 List of figures and tables Figure 1 Dimensions 5 Figure 2 Connection diagram 5 Figure 3 Display reports 6 Figure 4 Counter display for larger values 7 Table 1 Parameter overview ...

Page 4: ...and other obligatory rules such as accident prevention and environmental protection Do not make any changes and or modifications without the authorization of the manufacturer Spare parts have to correspond to the manufacturer defined standards This is only guaranteed if original spare parts are used Maintain the required or within this manual stated deadlines for repeating maintenance intervals Pr...

Page 5: ... has to be effected by authorized staff only Please arrange that the assembly is carried out by a specialist electronic company The installation of the EMS 58 is limited to the connection of the mains and the switched output according to the connection survey installed in the device Note that all wires are fitting exactly into the ISO box Figure 2 Connection diagram Page 5 ...

Page 6: ...e EMS 58 indicates the released time As far as the minimum insertion is not achieved the time is indicated flashing When the min insertion is achieved by inserting a further coin the display does not flash any more and the device starts If further coins are inserted the currently released time is indicated During the risk of an overpayment i e by inserting the next coin the maximum time would be e...

Page 7: ...isplay shows alternating a P followed by the parameter number and the value of the respective parameter Press the P button several times until you reach the required parameter You can find a listing of all parameters in Table 1 section 5 5 When you leave the last parameter all settings are stored and the EMS 58 is in free state again All parameters are stored electronically and do not loose their ...

Page 8: ...dded Counter 0 to 49999 P07 Operating hours 1 day Counts the operating hours of the connected device Counter 0 to 99999 9 P08 Operating hours 2 total not erasable Counts the operating hours of the connected device Counter 0 to 99999 9 P09 Minimum insertion Indicates the amount of money that has to be inserted at least Operator 0 1 to 99 9 P10 Time release Indicates how many minutes the device perm...

Page 9: ...ice will be free again after power on Table 1 Parameter overview 6 Technical data Power source 230V AC Mains frequency 50 60 Hz Power consumption 5W Max switched power Max 16A 230V Operating temperature 0 up to 40 C Operating humidity 30 up to 70 Weight 3 5 kg Dimensions 162 x 260 x 110 mm Data retention in off position 40 years Table 2 Technical data 7 Electronic Coin Selector Page 9 ...