background image

Installation and Technical Information

BEGA

Accessories

Please refer to the appropriate

accessory installation sheet for

further instruction when applicable.

In the interest of product improvement, BEGA reserves the right to make technical changes without notice.

Replacement Parts

BEGA  

1000 Bega Way, Carpinteria, CA 93013 (805)684-0533 Fax (805)566-9474 www.bega-us.com © Copyright BEGA-US 2017

Bollards for indirect light directed downwards

77 589

Tools Required:

3mm hex key

4mm hex key

1/4” masonry/concrete drill bit

Drill

Protection Class: 

IP65

Weight:

  14.8 lbs.

Dimensions
A:

    10-1/4 “

B:

    31-1/4 “

C:

    5-1/2 “

Relamping/Maintenance

Loosen (2) set screws and remove top casting with 

lens. Clean luminaire and lens using only solvent-free 

cleansers. Replace top casting and attached lens and 

tighten (2) set screws evenly, making sure the gasket 

is seated properly.

Lamp:

   19.2W LED

77 589

8/21/2017

Page 1 of 2

Description

Lens

Lens gasket

LED Driver (120-277V)

LED Module (4000K)

LED Module (3000K)

Part No

112530.2

830814

76089

LED-0638/940

LED-0638/930

Anchorage  

79 817

Notice to Installer for 77 589:

1. See page 2 for specific product safety warnings

2. Fixture may be damaged if connected to conduit systems that contain water - Article  

     

    300-5G of the National Electric Code requires that “Conduits or raceways through which   

    moisture may contact energized live parts shall be sealed or plugged at either or both 

    ends.”

3. It is recommended that when installing in planting areas the base of the bollard  

     

    be slightly elevated to avoid prolonged submerging during heavy rains.

4. Wet location listing does not imply suitability for exposure to standing water for  

     

    long periods of time.

5. 79 817 anchorage kit (included) must be installed in concrete pad/foundation.

6. LED and LED driver integral, provided inside luminaire housing.

79 817 anchorage installation:

1. Provide means to bring supply wiring to the bollard in accordance with local code. The    

    template has a 2-3/8” conduit hole for conduit entry.

2. Assemble anchorage kit. Unscrew the (3) hex bolts from the female couplers. Remove    

    each hex bolt and washer. Align each anchor bolt with the hole in the template. Attach 

    each anchor bolt to the template by replacing the washer and hex bolt and tightening.

3. Determine the fi nished grade for the application. Use leveling hardware to adjust  

 

    template to desired fi nished height after pouring.

4. Install anchorage kit using either method:

  

A. Attach template to forming or cross bracing using the (2) nail holes

  

provided in the template. Level template properly. Pour concrete.

  

B. Insert anchorage assembly into poured concrete. Concrete must be

  

vibrated to ensure proper anchorage setting. Level template properly. 

77 589 - installation:

1. Make supply wiring and luminaire wiring connections in the luminaire base:

 

MAIN VOLTAGE SUPPLY WIRE TO BLACK LUMINAIRE WIRE

 

NEUTRAL (COMMON) SUPPLY WIRE TO WHITE LUMINAIRE WIRE

 

GREEN GROUND WIRE TO GREEN LUMINAIRE WIRE 

    Dimming (if applicable):

 

 DIMMING CONTROL WIRE (+) TO POSITIVE DRIVER DIM CONTROL WIRE

 

 DIMMING CONTROL WIRE (-) TO NEGATIVE DRIVER DIM CONTROL WIRE

2. Mount bollard over mounting plate and tighten 4mm set screw at base to secure.

(5/16" - 18 x 10")