background image

ASSEMBLY INSTRUCTIONS

THANK YOU FOR PURCHASING THIS PRODUCT

For questions about this product, or for parts inquiries, please contact our Customer Service Center listed below.

Energy-Free Waterers
SF-2C, SF-4C, EF-1C, EF-2C, EF-4C

F-19857-8

TECHNICAL INFORMATION 70 110

Rev. 6-8-09 8-4-04

CUSTOMER SERVICE CENTER

PO Box 569
Columbus, NE 68602-0569

Ph: 1-800-447-2751
Fax: (402) 563-7447

CONGRATULATIONS

, you have just

purchased one of the most efficient
Energy-Free waterers ever manufactured.

The thermos bottle type construction will
hold the heat from the earth temperature
of the water and keep your Energy-Free
waterer warm in the winter and cool in the
summer. The closed dark interior inhibits
growth of bacteria, scum and algae.

The smooth rounded plastic exterior is
maintenance free and prevents injuries to
animals. It also prevents tongue injuries
from frigid steel.

All Behlen Country Energy-Free
Waterers carry a 5 year limited
warranty on the body and a 1 year
limited warranty on valves and
controls.

Installation and Recommendations

Please read over these instructions to make
sure you have all necessary components for
your installation. To ensure proper operation
in cold weather, it is highly recommended that
you purchase the optional Poly Earth Tube and
Shut-off Valve Kit.

Contact your dealer for

necessary items.

The Energy-Free waterer depends on water
entering the unit at ground temperature
(50-55° F.). This generally requires the 3/4" water
line to be at least 2 ft. below the frost line for
maximum performance.

Also, a minimum number of animals must use the
waterer to ensure that enough fresh water is
cycled through the waterer daily to prevent
freezing.

Energy-Free

Waterer

Minimum Number

of Animals

Gallon

Capacity

SF-2C

20

40

SF-4C

30

80

EF-1C

12

15

EF-2C

20

20

EF-4C

30

30

Under certain conditions, some icing may occur
on top of the balls in cattle units. Periodically
remove the ice with hot water or by tapping on the
balls, physically removing any ice.

We recommend a Behlen Insulated Earth Tube be
used. Where a waterer is replacing an electric
waterer and the Poly Earth Tube is less than 12"
deep and uninsulated, you may need to use heat
cable in the riser pipe. A 250 watt submersible
heater (52120088) is available for use when less
than the minimum number of animals are using
the waterer.

The drawings in these instructions provide slab
dimensions and approximate anchor locations for
various models. It is advisable to check the
waterer for exact dimensions for anchor locations.
This is because some variance due to the molding
process is normal and the dimensions on the
waterer may vary slightly from the drawing. Anchor
bolts (not provided) may be set in concrete or
anchors may be drilled in after the fountain is set
in place. Use anchors for 5/16" bolts.

NOTE:

The

slab should be at least 4" larger than the waterer
on all sides.

Poly Earth Tube Installation Instructions

Your insulated Poly Earth Tube is designed to
contain the earth’s heat from below the frost line,
and keep the frost from penetrating through the
tube and freezing the water pipe.

Summary of Contents for SF-2C

Page 1: ... the 3 4 water line to be at least 2 ft below the frost line for maximum performance Also a minimum number of animals must use the waterer to ensure that enough fresh water is cycled through the waterer daily to prevent freezing Energy Free Waterer Minimum Number of Animals Gallon Capacity SF 2C 20 40 SF 4C 30 80 EF 1C 12 15 EF 2C 20 20 EF 4C 30 30 Under certain conditions some icing may occur on ...

Page 2: ...s generally attached to the rim of the waterer body Attach the four Tie Down Brackets with the four 5 16 x 1 lag screws Use the small hole for mounting to the waterer the large hole will be used for mounting to the concrete pad DO NOT OVER TIGHTEN LAG SCREWS Just snug the bracket up to the body NOTE These Tie Down Brackets are not required on the SF 4C The SF 4C has molded in mounting pads Turn th...

Page 3: ...Typical setup with the EFSK Shut off Kit inside Earth Tube Typical setup without Shut off Valve ASSEMBLY INSTRUCTIONS F 20560 1 Rev 6 8 09 1 10 08 Typical Remote setup with the EFSK Shut off Kit ...

Page 4: ... 2C FF 4C SF 2C EARTH TUBE A Model A B Min Slab Size FF 1C 21 1 2 8 29 x 34 FF 2C 21 3 4 18 28 x 44 FF 4C 36 1 2 18 44 x 44 SF 2C 27 3 4 22 30 x 48 SF 4C 42 1 2 11 48 x 48 CONCRETE PAD SPECIFICATIONS F 19859 3 Rev 3 5 09 8 9 02 EARTH TUBE A B SF 4C B ...

Page 5: ... tape from around the top of the valve STEP 2 Slide off cover pivot upper arm up and remove the plunger STEP 3 Clean the rubber part of the plunger and opening to the valve of any mineral deposits or dirt buildup that may be obstructing the normal operation of the valve STEP 4 If the rubber seal is grooved but still pliable not hard and brittle you may flip it over and use the backside of the seal...

Page 6: ...F 20441 4 7 06 ASSEMBLY INSTRUCTIONS ...

Page 7: ...of the valve When attaching the float arm to the valve be sure to attach the arm to the correct side of the valve The grooves on the valve and float arm must match Please note that the valve has coarse grooves on one side and fine grooves on the other The fine grooved side is used with the float arm see below right for details To adjust the water level in the waterer loosen the thumb screws and po...