background image

page 1 of 10

985-40000-01084 Rev.A

2021-02-03
Confidential, for internal use only. Not to be reproduced.

Analog 4-Voice Polyphonic Synthesizer with 

37 Full-Size Keys, 4 VCOs, Classic Ladder Filter, 

LFO, BBD Stereo Chorus, Distortion, 32-Step 

Sequencer and Arpeggiator

Synthesizers and Samplers

POLY D

User Support Bulletin

Calibration Procedure

Summary:

POWER LED

Region B LEDs

Region A LEDs

CALIBRATION CHANNELS: 
CHANNEL 1 — PITCH WHEEL MAX/MIN
CHANNEL 2 — PITCH WHEEL dead zone
CHANNEL 3 — MOD WHEEL MAX/MIN
CHANNEL 4 — AFTERTOUCH MIN
CHANNEL 5 — AFTERTOUCH MAX

Introduction

The unit is carefully calibrated at the factory. The performance may change over time or due to environmental changes,  

and the following recalibration procedures can be used to bring it back to its factory settings.

Summary of Contents for POLY D

Page 1: ...s POLY D User Support Bulletin Calibration Procedure Summary POWER LED Region B LEDs Region A LEDs CALIBRATION CHANNELS CHANNEL 1 PITCH WHEEL MAX MIN CHANNEL 2 PITCH WHEEL dead zone CHANNEL 3 MOD WHEEL MAX MIN CHANNEL 4 AFTERTOUCH MIN CHANNEL 5 AFTERTOUCH MAX Introduction The unit is carefully calibrated at the factory The performance may change over time or due to environmental changes and the fo...

Page 2: ...button KYBD STEP then power on POLY D 2 When all the LEDs are running during the first 3 seconds after power on press button 3 to start the calibration routine 3 Power LED will blink RED Follow all steps in the order in which they are presented Start PITCH WHEEL Calibration 1 Press button 1 to calibrate PITCH WHEEL 2 Button 1 LED will light and region A LEDs will indicate current PITCH WHEEL posit...

Page 3: ...03 Confidential for internal use only Not to be reproduced page 3 of 10 Synthesizers and Samplers POLY D Calibrate PITCH WHEEL Maximum Position Move the PITCH WHEEL to its maximum position Region A LEDs will show maximum position of PITCH WHEEL ...

Page 4: ...03 Confidential for internal use only Not to be reproduced page 4 of 10 Synthesizers and Samplers POLY D Calibrate PITCH WHEEL Minimum Position Move the PITCH WHEEL to its minimum position Region A LEDs will show maximum position of PITCH WHEEL ...

Page 5: ...tion 1 First release PITCH WHEEL 2 Press button 2 to calibrate PITCH WHEEL dead zone 3 Button 2 LED will light on and region A LEDs will indicate current PITCH WHEEL position Calibrate PITCH WHEEL dead zone Move the PITCH WHEEL within the dead zone where you don t feel the tension of the spring This will ensure that no pitch information is sent while pitch wheel is not being touched ...

Page 6: ...se only Not to be reproduced page 6 of 10 Synthesizers and Samplers POLY D Start MOD WHEEL Calibration 1 First move MOD WHEEL to its minimum position 2 Press button 3 to calibrate MOD WHEEL 3 Button 3 LED will light and Region A LEDs will indicate current MOD WHEEL position ...

Page 7: ...02 03 Confidential for internal use only Not to be reproduced page 7 of 10 Synthesizers and Samplers POLY D Calibrate MOD WHEEL Maximum Position Move the MOD WHEEL to its maximum position Region A LEDs will show maximum position of MOD WHEEL ...

Page 8: ...lers POLY D Calibrate MOD WHEEL Minimum Position Move the MOD WHEEL to its minimum position Region A LEDs will show minimum position of MOD WHEEL Start AFTER TOUCH Minimum Position Calibration 1 Press button 4 to calibrate AFTER TOUCH minimum position 2 Button 4 LED will light on and region A LEDs will indicate current AFTER TOUCH value ...

Page 9: ...sition Apply a small pressure to any one of the keys or multiple keys or do not apply any pressure This will ensure that no after touch information is sent while keys are not being pressed Start AFTER TOUCH Maximum Position Calibration 1 Press button 5 to calibrate AFTER TOUCH maximum position 2 Button 5 LED will light on and Region A LEDs will indicate current AFTER TOUCH value ...

Page 10: ... Coolaudio are trademarks or registered trademarks of Music Tribe Global Brands Ltd Music Tribe Global Brands Ltd 2021 All rights reserved Synthesizers and Samplers POLY D Calibrate AFTER TOUCH Maximum Position Apply pressure to any one of the keys or multiple keys until AFTER TOUCH value stops increasing Region A LEDs will indicate current AFTER TOUCH value Calibration Complete Press SHIFT STEP t...

Reviews: