GS920
          Gas Detector with Earthquake-proof Device

The GS920, thanks to its innovative 

Seismic Detection

” feature and the possibility

of  selecting  the  “Intrinsic  Safety  Control”,  is  a  leading-edge  technological  device.
A  microprocessor  was  used  to  create  a  complete  surveillance  and  control  system
with  maximum  flexibility.
Together  with  its  catalytic  sensor  technology,  it  detects  the  presence  of  explosive
gas,  such  as:  Methane  and  LPG,  with  trip  threshold  calibrated  at  10%  of  Lower
Explosion  Limit.
Using  the  built-in  relay  it  can  activate:  solenoid  valves,  sirens,  and  any  other  alarm
signal  device.  The  micro  switch  makes  it  possible  to  select  the  relay  impulse
functioning,  to  connect  manual  reset  solenoid  valves,  or  the  continuous  functioning,
and  to  activate  N.C.  class  “A”  solenoid  valves  and  sirens.
Another  micro  switch  allows  turning  on/off  the  “

Intrinsic  Safety

”.

The  power  supply  unit  allows  driving  of  a  manual  reset  solenoid  valve  with  a  12Vdc
coil,  without  any  buffer  battery.  If  the  voltage  absorption  is  too  high,  you  can  later
integrate  a  suitable  backup  battery.  The  battery  is  recharged  automatically.
The  

Seismic  Control

  allows  closure  of  the  solenoid  valve,  stopping  the  gas

original  source!  This  control  is  vital  in  seismic  regions!  The  relay,  free  of  voltage,
allows  installation  of  multiple  detectors  on  a  single  solenoid  valve,  providing  control
of  multiple  dangerous  environments.
The  technical  scheme  is  completed  by  a  circuit  that  controls  the  catalytic  sensor
“efficiency  level”,  and  signals  any  possible  fault.
These  technical  features  make  the  detector  ideal  for  civil  environment  safety
according  to  EUROPEAN  REGULATIONS.

 Installation and user guide

Summary of Contents for GS920

Page 1: ...an activate solenoid valves sirens and any other alarm signal device The micro switch makes it possible to select the relay impulse functioning to connect manual reset solenoid valves or the continuous functioning and to activate N C class A solenoid valves and sirens Another micro switch allows turning on off the Intrinsic Safety The power supply unit allows driving of a manual reset solenoid val...

Page 2: ...traordinary maintenance and its out of service removal at the end of the functional life guaranteed by the manufacturer must be carried out by authorized and or specialized personnel Do not allow it to become wet The detector can be seriously damaged when immersed in water Remember that the probe has an IP30 protection degree Do not drop it Heavy knocks or falls during transportation or installati...

Page 3: ...er level at 10 of L E L 4 Micro switches Switch 1 Positioning the switch to ON Intrinsically safe operation the relay is excited at the end of the latency time and switches on each alarm Positioning the switch to OFF Normal operation the relay switches on each alarm Switch 2 Positioning the switch to ON the relay is set to impulse functioning Each pulse lasts about 30 seconds Positioning the switc...

Page 4: ...Pagina 4 34 mm 50 mm Embedded box 503 70 mm 105 mm 5 mm 115 mm 84 mm 115mm Dimensions ...

Page 5: ... its measurement It should be located away from sources of heat ventilators or fans It must not be installed on a wall in plasterworch It must be installed only on walls in masonry Once the device has been turned on the MAINS LED will start blinking for about 60 seconds after which it will remain ON Now the GS920 is ready for detection of explosive gas After 24 hours from installation begin the se...

Page 6: ...les cornices also unbraced parapets and architectural ornaments Some cracks in masonry C Waves on ponds water turbid with mud Small slides and caving in along sand or gravel banks Large bells ring Concrete irrigation ditches damaged Steering of motor cars affected Damage to masonry C partial collapse Some damage to masonry B none to masonry A Fall of stucco and some masonry walls Twisting fall of ...

Page 7: ...ndon the building and call the emergency services when outside fire department distributors etc If the device does not start up Check that the 230V power is correctly connected If the fault LED lights up If the YELLOW LED is remains ON check the detection capsule status It is probably faulty and has to be replaced Call an authorized technician If the detector is repeatedly issuing an alarm Check t...

Page 8: ...tion Scheme of GS920 Detector N C C NO N Ph 12 V 1 2 3 4 5 6 7 8 Without Intrinsic Safety With Intrinsic Safety Normally closed electrovalve 230VAC The Relay is free of voltage Range of relay contact 10A resistive The electrovalve is a N C Automatic or manual retrig Note To connect a N O Electrovalve swap the connections between pin 8 and 6 The Relay is free of voltage Range of relay contact 10A r...

Page 9: ... free of voltage Range of relay contact 10A resistive The drawn electrovalve is a Normally Open type with manual reset and with a power supply of 12V 600mA MAX The activation is impulsive Power Supply 230 V AC Normally open electrovalve 230V AC with intrinsic safety Ph N 1 2 3 4 5 6 7 8 The Relay is free of voltage Range of relay contact 10A resistive The drawn electrovalve is a N C type with manu...

Page 10: ...open electrovalve 230V AC without intrinsic safety The Relay is free of voltage Range of relay contact 10A resistive The drawn electrovalve is a Normally Open type with manual reset and with a power supply of 12V 600mA MAX The activation is impulsive Power Supply 230 V AC Electricalconnections ...

Page 11: ...Page 11 Note ...

Page 12: ... 3 years from manufacturing date in agreement with the following conditions The components acknowledged as faulty will be replaced free of charge excluding the replacement of plastic or aluminium cases bags packing batteries and technical reports The device must arrive free of shipment charges to BEINAT S r l Defects caused by unauthorized personnel tampering incorrect installation and negligence ...

Reviews: