Description and Operating Instructions
IP67 Power Supply 150W

PC150/xx/48V-IP67

For supplying power to Hirschmann Power
over Ethernet products of the OCTOPUS
family.

The PC150/36V/48V-IP67 power unit sup-
plies an output voltage of 48 VDC from an
input voltage of 24-48 VDC.

The PC150/72V/48V-IP67 power unit sup-
plies an output voltage of 48 VDC from an
input voltage of 72-110 VDC.

– Permitted ambient temperature  -40 to +70

°C (in accordance with EN50155 for max.
10 minutes up to +85 °C).

– No additional cooling element necessary,

voltage transformer is integrated into
cooling element.

– 150 W power output.

– Class I equipment.

– IP67 enclosure type.

– Conforms to EN50155 class C1 S2.

– Output has short-circuit protection.

– Input has polarity reversal protection.

– Integrated fuse, exchangeable.

– Secondary line has suitable connectors for

OCTOPUS supply voltage.

Order No.

943 968-001
943 968-101

Summary of Contents for HIRSCHMANN PC150 48V-IP67 Series

Page 1: ...ge of 48 VDC from an input voltage of 72 110 VDC Permitted ambient temperature 40 to 70 C in accordance with EN50155 for max 10 minutes up to 85 C No additional cooling element necessary voltage transformer is integrated into cooling element 150 W power output Class I equipment IP67 enclosure type Conforms to EN50155 class C1 S2 Output has short circuit protection Input has polarity reversal prote...

Page 2: ...al equipment designed for use within certain voltage limits The EU declaration of conformity is kept available for the responsible authorities in accordance with the above mentioned EU directives at Hirschmann Automation and Control GmbH Stuttgarter Straße 45 51 D 72654 Neckartenzlingen www hirschmann com The product can be used in the resi dential sphere residential sphere business and trade sphe...

Page 3: ...ns of the PC150 36V 48V IP67 and PC150 72V 48V IP67 power supply units in mm 1 2 PIN ASSIGNMENTS 2 2 ATTACHING THE FERRITE A ferrite incorporated into the secondary cable is included in the delivery Fig 2 Ferrite mounted on the secondary cable of the device 2 3 CONNECTING THE SUPPLY VOLTAGE AND MOUNTING THE PROTECTIVE CONDUCTOR M Connect the protective conductor see chapter 1 2 Pin assignments bef...

Page 4: ... Class of protection Class I equipment Enclosure type IP 67 Insulation resistance Primary secondary 2000 V AC Primary housing 1000 V AC Secondary housing 1500 V AC Insulation resistance 500 Megaohm Approvals Standards IEC EN 61010 1 VDE 0411 1 IEC EN61131 2 2007 CE Declaration programmable logic controllers EN50155 Class S1 C2 Railway applications electronic systems in railway vehicles environment...

Page 5: ...r input 2 kV line earth IEC EN61000 4 6 Line conducted interference voltages 150 kHz to 80 MHz 10 V Mechanical components Dimensions without cables W x H x L 115 mm x 65 mm x 240 mm Weight 3 100 g Housing material Aluminum UL94 V0 Casting compound Polyurethane Vibration resistance IEC60068 2 6 Test Fc Test level according to IEC61131 2 EN61373 category 1 Class A broadband noise installation accord...

Page 6: ...n Automation and Control GmbH Stuttgarter Straße 45 51 D 72654 Neckartenzlingen Germany www hirschmann com Technical support https hirschmann support belden com Printed in Germany Subject to alterations 04 1122 ...