F6C110-RKM-2U

F6C150-RKM-2U

F6C230-RKM-2U

F6C320-RKM-3U

Capacity

1100

1500

2300

3200

Max Load

660

900

1380

1920

Voltage Range

Frequency

AVR Detection Tolerance

AVR Output Voltage Range

AVR Response Time

Voltage (On battery)

Frequency (On battery)

Waveform

Spike Protection

EMI/RFI Filter

Overload Protection

Unit Input

Telecommunication

Short Circuit in AC Mode or 

Battery Mode

Voltage / Amps

12V/4.5Ah (4 pcs.)

12V/7.2 Ah (4 pcs.)

12V/12Ah (4 pcs.)

12V/12Ah (4 pcs.)

Battery Protection

40A/32V Fuse (2 Pcs.)

40A/32V Fuse (1 Pcs.)

Type

Typical Recharge Time

Protection

Battery Run Time

On Battery

Battery Low

Overload 

Fault

Battery Test

Audible Noise

Weight (kgs/lbs)

23/50

25/55.11

30/66.13

41.5/91.48

H x W x D (cm)

13.2 x 56.5 x 57

H x W x D (in.)

5.19 x 17 x 16

AC Power On (1 Beep)

Power Off (1 Beep)

Cold Start (Turns DC Power 

On)

Battery Test (On AC Mode)

Buzzer Silence

Battery

Alarm

Auto Sensing 50/60Hz  ± 3Hz

True Sine Wave

16A/250V

1 In, 1 Out (RJ45/RJ11) jacks

UPS shuts down

500 Joules

FCC Part 15 Class B Certified

UPS Low to high voltage switch to battery: 91 ~ 145 ± 3 Vac

Model

Input

Output

Protection & 

Filtering

Voltage Regulation (AVR)

Physical

Sealed, maintenance free lead acid

< 8 Hours

Automatic self discharge protection, replace battery indicator LED

Environment

Ambient Operation

Communication Port

8.8 x 56.5 x 57

3.46 x 17 x 16

0 ~ 40º C Operating Temperature

Electronic overload and short circuit protector

80 ~ 150 Vac

Auto Sensing 50/60Hz  ± 6Hz

AVR Boost Increases 17% of Voltage if input is 91 ~ 145 Vac

AVR Buck Reduces 13% of Voltage if input is 132 ~ 145 Vac.

± 6Vac

On-line operation for input between 91 ~ 145 Vac. Output will be 101 ~ 136 Vac.

<200ms

110/120/127 DIP Switch Selectable

Front Panel

UL 1778, cUL, UL 497A, UL 497B, Meets UL 1449, CSA22.1, CE EMC, CE Safety, TUV, EMI (FCC Class 
B), EN55022, EN50081-1, EN50082-1, EN50091-2, IEC 801-2 Level 4, IEC 801-4 Level 3; IEC 801-5 Level 
3, FCC Part 68, 

Press button and hold longer than 1 sec.

Press button and hold longer than 1 sec.

Press button and hold longer than 1 sec.

Press button and hold less than 0.5 sec.

Press button and hold less than 0.5 sec.

Compliance

0 ~ 95% Relative Humidity (Non-condensing)

< 45 dBA at 1 meter

Solid Red LED and Intermittent Audible Alarm

Flashing Yellow LED and Intermittent Audible Alarm

Flashing Red LED and Intermittent Audible Alarm

Solid Red LED Light

Flashing Yellow LED and Intermittent Audible Alarm

RS232 Serial Ports

Rack Mount UPS