background image

Providing sustainable energy solutions worldwide

178 111 35-2    2018-03–06

Installation- and maintenance instruction

BFG1

STG146

Biogas

Summary of Contents for BFG1

Page 1: ...Providing sustainable energy solutions worldwide 178 111 35 2 2018 03 06 Installation and maintenance instruction BFG1 STG146 Biogas...

Page 2: ......

Page 3: ...___________________________________________12 3 MULTIBLOC____________________________________________________________13 3 1 DMV DLE ___________________________________________________________13 3 1 1...

Page 4: ...in a dry environment max 80 relative humidity no condensation Temperature 20 to 60 C Check that the burner is compatible with the boiler s output range All components must be installed without being...

Page 5: ...not be put into operation without proper safety and protection devices A Class BE fire extinguisher is recommended It is forbidden to alter thedesign or use accessories which have not been approved b...

Page 6: ...Leakage check 1 year 3000 hrs Filter 1 year replacement at p 10 mbar 3000 hrs replacement at p 10 mbar Electrodes Replacement Cleaning 1 year Replacement Cleaning 3000 hrs Brake disc Replacement Clean...

Page 7: ...sions BFG1 Biogas The above mentioned measurements are maximum measurements They can vary depending on which components are used 135 286 B A 0 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 10 15 20 25 30 35 40 45 50...

Page 8: ...8 General 1 1 Description BFG1 7 8 10 11 12 13 14 15 16 22 1 2 3 4 5 6 24 23...

Page 9: ...essure switch 9 10 Air intake 11 Air regulation 12 Electric connection 13 Gas burner control 14 Reset button 15 Nozzle assembly adjustment 16 Screw for division of burner in front and rear part 17 Noz...

Page 10: ...10 General 2 Dimensions STG Biogas 290 139 11 13 14 15 244 192 450 103 61 249 1 0 0 0 1 0 2 0 3 0 4 0 40 60 80 100 120 Connection pressure 45 mbar 60 H4...

Page 11: ...11 General 7 8 10 9 1 2 3 5 6 12 4 2 1 Description STG 23 24 16...

Page 12: ...ressure switch 9 Test point for the air pressure switch on the low pressure side 10 Air intake 11 Air regulation 12 Electric connection 13 Gas burner control 14 Reset button 15 Nozzle assembly adjustm...

Page 13: ...DMV D 11 Type DMV DLE 11 Nominal widths Rp 1 2 Rp 2 Electrical connection IEC 730 1 VDE 0631 T1 Volt U n AC 230 V Valve 2 x Class A Ambient temperature 15 C 60 C IP 54 Family 1 2 3 Max operating press...

Page 14: ...ol and function control 1 Loosen screws A and B do not remove Figs 1 and 2 2 Remove screws C and D Figs 1 and 2 1 2 3 1 1 Disassembly of the the Multiblock Screw plugs 1 2 3 may also be replaced by a...

Page 15: ...ing valve Lead seal eye 3 in 1 5mm cap stand headed screw After setting the requested pressure setpoint 1 Close protective valve 1 2 Route wire through 2 and 3 Fig 2 3 Press lead around wire ends keep...

Page 16: ...ten socket head screw so that hydraulic brake can just be turned 9 Coat countersunk screw A with locking varnish 10 Leakage test Pressure tap at sealing plug 2 DMV 507 520 11 Pressure tap at sealing p...

Page 17: ...nge 5 500 mbar Family 1 2 3 Outlet pressure range 2 5 200 mbar Dimensions mm e c f h DN a f e d b b h d DN c a 3 2 Gas pressure regulator Type FRS Nominal diameters Rp 3 8 Rp 2 1 2 DN 40 DN 150 2 Pres...

Page 18: ...4 G1 4 365 2 50 FRS 520 058 628 500 Rp 2 170 250 47 310 G1 2 G1 4 G1 4 450 3 50 FRS 525 083 303 500 Rp 2 1 2 230 285 60 365 G1 2 G1 4 G1 4 550 6 00 FRS 5065 058 792 500 DN 65 290 285 95 405 G1 2 G1 4...

Page 19: ...clockwise Reducing outlet pressure setpoint 1 Check setpoint 2 Screw on protective cap A 3 Attach lead seal Page 5 Replace setting spring 3 4 1 Remove protective cap A Release spring by turning adjus...

Page 20: ...20 General 4 ELECTRIC EQUIPMENT LME 4 1 Wiring diagram Alt 1 Enl DIN 4791 Alt 2 Alt 3...

Page 21: ...ON Thermostat ON Gas pressure switch ON A check that the air pressure switch does not indicate fan pressure is carried out 2 Burner motor starts A check that the air pressure switch indicates sufficie...

Page 22: ...ng green Illegal flame signal during start up Green Red Undervoltage Yellow Red Fault alarm Red Blinking code for fault codes Blinking red Interface diagnostics Red flicking 4 2 1 1 Diagnosing alarm c...

Page 23: ...g defective or fouled fuel valves defective or fouled flame monitoring Blinking 8 x Free Blinking 9 x Free Blinking 10 x Connection fault or internal fault outgoing contacts or other faults Blinking 1...

Page 24: ...24 General...

Page 25: ...25 General...

Page 26: ...26 General...

Page 27: ......

Page 28: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...

Reviews: