background image

Installation, Service and User Instructions  

(French version page 9)  

                                                      

 

                              

                              

                                       

DIMENSIONS: 29 

7/16

’’ 

(748 mm)

(W) x 21

1/4

’’ 

(540 mm)

(D) 

Models B7G0..A8X (2 or 5)D  

Q30400X/LP 

Models B7G0..Q8X (2 or 5)D  

QB30400X/LP 

 

IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR’S USE. 
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. 
OBSERVE ALL GOVERNING CODES AND ORDINANCES. 

 

WARNING:  If  the  information  in  this  manual  is  not  followed  exactly,  a  fire  or 
explosion may result causing property damage, personal injury or death. 
Do not store or use gasoline or other flammable vapors and liquid in the vicinity of 
this or any other appliance. 
WHAT TO DO IF YOU SMELL GAS 
     - Do not try  to light any appliance. 
     - Do not touch any electrical switch. 
     - Do not use any phone in your building. 
     - Immediately call your gas supplier from a neighbor’s phone. Follow   
       the gas supplier’s instructions. 
     - If you cannot reach your gas suppliers, call the fire department. 
Installation  and  service  must  be  performed  by  a  qualified  installer,  service  agency 
or the gas supplier. 

Read this instruction booklet before installing and using the appliance. 

The manufacturer will not be responsible for any damage to property or to persons caused by 
incorrect installation or improper use of the appliance. 

The manufacturer reserves the right to make changes to its products when considered necessary and useful, 
without affecting the essential safety and operating characteristics. 

This appliance has been designed for non-professional, domestic use only. 

                                                                                                                                               Cod. 3100348 

Built-in gas  hotplates

 

Summary of Contents for B7G0 A8X Series

Page 1: ...pliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas suppliers call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Read this instruction booklet before installing and us...

Page 2: ...as supply line Do not bend or damage the flexible connector when moving the cooktop The pressure regulator has female pipe thread You will need to determine the fitting required depending on the size of your gas supply line the flexible metal connector and the shutoff valve The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes wi...

Page 3: ... indicated in the table n 1 and are shown and in the fig 1 2 Range hoods and exhaust fans shall be installed in accordance with the manufacturer s instructions However in no case shall the clearance between the top of the highest burner of the cooking appliance and the range hood be less than 25 1 2 650mm Any other downward facing combustible surface less than 600mm above the top of the highest bu...

Page 4: ...WHEN CONNECTING THE SUPPLY DO NOT OVER TIGHTEN The regulated pressure For NG is 4 w c See Fig 5 6 For gas inlet position of appliance refer Fig 5 6 and 7 After installing the gas supply and making all connections check thoroughly for possible leaks Turn all control knobs on the unit to OFF position Open the valve on the gas supply Using a soap and water solution check each gas connection one at th...

Page 5: ...zles with those designed for the new gas supply according to the information given in TABLE A shown below TABLE A Adapting to different types of gas Burner Position Inj size Gas Pressure Max Rate Min Rate By pass size 1 100mm Type i w c BTU h W BTU h W 1 100mm Auxiliary Front R 92 NG 4 3750 1098 900 264 Regulated 56 LP Propane 11 3750 1098 900 264 29 Semi Rapid Rear L 117 NG 4 6000 1759 1500 439 R...

Page 6: ...l Burner 2 Medium burner 3 Rapid burner 4 Dual burner 5 Front right side burner control knob 6 Front left side burner control knob 7 Rear left side burner control knob 8 Rear right side burner control knob Service maintenance instructions Service and maintenance only to be carried out by an authorised person To replace parts such as burners valves and electric components the hotplate must be remov...

Page 7: ...arge flame and then press the knob down to activate the spark ignition Once ignited keep pressing the knob for about 10 seconds to allow the flame to heat the thermocouple If the burner does not remain alight after releasing the knob repeat the above procedure Use of the Dual burner Fig 14 This model controls both the central and the external crown of the burner with just one valve To ignite the c...

Page 8: ... be disconnected from the power supply Cleaning the work surface periodically clean the burner heads the enamelled steel pan supports and the burner caps using warm water Any spillage must always be removed as soon as possible using a rag If it become difficult to open or close a valve do not force it but immediately request the assistance of the technical service personnel Cleaning the enamelled ...

Page 9: ...ouchez aucun interrupteur électrique N utilisez aucun téléphone dans votre établissement Appelez immédiatement votre fournisseur de gaz par le téléphone d un voisin Suivez les instructions du fournisseur de gaz Si vous ne pouvez pas atteindre vos fournisseurs de gaz appelez les pompiers L installation et le service doivent être exécutés par un installateur qualifié une agence de service ou par le ...

Page 10: ...u CGA de 1 5 mètres de longueur maximum I D recommandé pour le branchement de cette table de cuisson au conduit d amenée des gaz Ne pliez pas ou n endommagez pas le connecteur flexible en déplaçant la table de cuisson Le régulateur de pression a un filetage au pas du gaz femelle de Vous devrez déterminer le raccordement demandé selon la dimension du conduit d amenée des gaz du connecteur en métal ...

Page 11: ... 1 2 Exigences 1 Distances des meubles suspendus Valeurs minimum Les distances minimum devront être conformes aux valeurs minimum indiquées dans la table n 1 et sont illustrées dans la fig 1 2 Les hottes de cuisine et les ventilateurs aspirant doivent être installés selon les instructions du fabricant Cependant dans aucun cas la distance entre la partie supérieure du brûleur le plus haut de l appa...

Page 12: ...VEC UNE CLE LORSQU ON BRANCHE L ALIMENTATION NE PAS SERRER La pression réglée pour GN est de 4 colonne d eau Voir Fig 5 6 Pour la position d entrée du gaz de l appareil référez vous à la Fig 5 6 et 7 Après avoir installé l alimentation du gaz et après avoir effectué tous les branchements contrôlez soigneusement les éventuelles fuites Tournez tous les boutons de commande de l unité sur la position ...

Page 13: ...ns le meme local en chaque cas elle doit etre eventuellement installée conformement aux normes nationals en vigueur Conversion à différents types de gaz Avant d effectuer n importe quel travail d entretien débranchez l appareil de l alimentation gaz et électrique Pour le Gaz Naturel utilisez le régulateur illustré en Fig 5 Pour LP Gaz utilisez celui illustré en Fig 5 REMPLACEMENT DES BECS POUR L U...

Page 14: ...ession du type convertible pour l utilisation avec Gaz Naturel à une pression de sortie nominale de 4 w c colonne d eau ou LP gaz à une pression de sortie nominale de 11 w c colonne d eau et il est prédisposé par l usine pour fonctionner avec un de ces gaz pression comme indiqué sur les étiquettes de réglage apposées sur l appareil l emballage et le livret d instructions Pour convertir le régulate...

Page 15: ... l unité Pour le positionnement de la prise au mur pour le branchement de la bonde de mise à terre à trois pôles de l appareil voir les indications illustrées en Fig 1 2 ATTENTION Après la première installation de l appareil ou après n importe quelle intervention d entretien concernant les parties principales du gaz de l appareil effectuez le test de fuite en utilisant de l eau avec du savon sur l...

Page 16: ...me externe Tourner la manette sur la position 2 pour avoir la couronne externe au minimum et la couronne interne au maximum de la flamme En tournant la manette sur la position 3 on a la couronne interne au maximum et la couronne externe éteinte En tournant la manette sur la position 4 on a la couronne interne au minimum et la couronne externe éteinte Avertissement Il est recommandé de ne pas essay...

Page 17: ...rmer une valve ne la forcez pas mais demandez immédiatement l assistance du personnel du service technique Nettoyage des parties émaillées Les parties émaillées devront être nettoyées fréquemment avec de l eau savonneuse N utilisez pas de poudres abrasives Ne laissez pas de substances acides ou alcalines sur les parties émaillées comme par exemple du vinaigre jus de citron sel sauce tomate etc et ...

Page 18: ...18 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 ...

Page 19: ...19 Fig 7 Fig 8 Fig 9 Fig 10 Inches mm A 1 11 16 43 B 1 3 16 30 C 1 1 16 27 E 4 7 16 112 ...

Page 20: ...20 Fig 11 Fig 12 Fig 14 Fig 15 ...

Reviews: