background image

Page 1

MODEL 

ILB3

IN-LINE BLOWER

WARNING 

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer.

If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service

panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service discon-
necting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a quali-

fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting

of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage elec-

trical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be

marked as appropriate for the application and be connected to
a GFCI (Ground Fault Interrupter) - protected branch circuit.

9. Never place a switch where it can be reached from a tub or

shower.

10. This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1. Never leave surface units unattended at high settings. Boilovers

cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.

2. Always turn hood ON when cooking at high heat or when

flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Pepper-
corn Beef Flambe’).

3. Clean ventilating fans frequently. Grease should not be allowed

to accumulate on fan or filter.

4. Use proper pan size. Always use cookware appropriate for the

size of the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOW-
ING:*

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal

tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.

2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - vio-

lent steam explosion will result.

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 4.

!

 FOR DOMESTIC COOKING ONLY 

!

4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already

know how to operate it.

B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.

CAUTION 

!

1. For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power
unit.

3.

If ventilator is installed in an unconditioned space (such as
an attic):

 Surround the ventilator with thermal insulation - to

minimize possible condensation.

4. Please read specification label on product for further informa-

tion and requirements.

WARNING 

 

TABLE OF CONTENTS

This manual is divided into sections as follows:

!

“TYPICAL INSTALLATION”

This section shows a common installation.
- Mounting (New Frame Construction)
- Mounting (Existing Frame Construction)
- Mounting Using Hanger Kit (included)
- Ducting (Horizontal blower discharge)
- Wiring

!

“MOUNTING OPTIONS”

!

“WIRING PLATE POSITION”

!

“DUCTING OPTIONS”

- Blower Discharge Positions
- Ducting (Vertical blower discharge)

!

“USE AND CARE”

!

“SERVICE PARTS”

!

“WARRANTY”

Summary of Contents for ILB3

Page 1: ...od ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Pepper corn Beef Flambe 3 Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOW ...

Page 2: ...ER KIT included Blower factory shipped in straight through discharge position TYPICAL INSTALLATION Blower factory shipped in straight through discharge position ACCESS PANEL ACCESS PANEL SCREW GRILLE NUT Install into square holes in housing MOUNTING BRACKET 10 ROUND DUCT OUTLET 10 ROUND DUCT INTAKE HANGER KIT NUT WASHER HANGER KIT BOLT WASHER HANGER KIT EYE BOLT HANGER KIT CHAIN 8 TO 10 ROUND TRAN...

Page 3: ...o 101 2 yyy yyyy 12 1 to 2 yyyy yyy yyy yyy MOUNTING OPTIONS yy yyyy 12 11 8 MAX Mounting brackets in factory shipped position Outlet parallel to joists New construction yyy yyyy 12 10 3 4 to 11 3 4 yyyy yyy yyy 12 20 hex nuts secure mounting brackets to housing Loosen and re tighten or remove and replace nuts as necessary for desired mounting bracket position Mounting brackets flipped over and mo...

Page 4: ...chaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan will at its option repair or replace without charge any p...

Reviews: