point by point training
CLEANPOINT
BHC
317.923.3211
WWW.BHCINC.COM
ISO 9001:2008 CERTIFIED
Clean Up
Remove tank.
Refer to product label for proper
disposal of unused solution.
Rinse tank with water.
For preventative maintenance:
Rinse nozzle with hot water after
every couple of uses.
(Instructions for nozzle removal
and wrench included with unit)
7
Spray
Turn on the unit and squeeze the
trigger. Optimum sprayer distance is 2
feet (24 inches).
6
Adjust Nozzle
Rotate the nozzle
to select the
medium (80
micron) or large
(110 micron)
setting.
BHC recommends
80 and 110
micron nozzles
for use with our
disinfectants.
5
Replace Cap/Tank
4
Fill Tank
BruTab 6S:
If using pre-diluted BruTab
6S solution, fill the tank with
disinfectant solution.
For Disinfectant Solution use
13.1g tablet as follows:
1. Fill tank with 2 gallons (256
oz) clean water.
2. For minimum 5382 ppm (4
minute TB) add 10 tablets.
3. For minimum 4306 ppm
(4 minute C. diff, 1 minute
Norovirus and Bloodborne
pathogens) add 8 tablets.
4. For a minimum 1076 ppm
(10 minute Hospital Use) add
2 tablets
For Sanitizer Solution use 3.3g
tablet as follows:
1. Fill tank with 2 gallons (256
oz) clean water.
2. For a minimum 100 ppm
(Food Sanitizer Claim), add 1
tablet.
Allow to completely dissolve
before using.
3
Remove Cap/Tank
2
Charge Battery
This side is fully
illuminated when
charged.
(2 hour charge time)
Note: If wet, the battery will not work or charge.
Keep liquids from touching battery and charger
contacts. Wipe battery and charger contacts with
dry cloth immediately if they come into contact
1
Use Directions - Backpack
Victory Sprayer
Medium
Large
Small
BruTab 6S
Product No.
13.1g is 161021-8N
3.3g is 161021-8G
Performex
Product No.
161052-33
Performex:
Fill tank
with diluted
solution from
the dispenser.
750-274
Performex
RTU:
Fill tank with
solution from
the bottle.
Performex RTU
Product No.
161051-Q6
Tank is
removable
for filling
convenience.
Note: It is not
necessary to
remove tank for
filling.
13.1g
3.3g