background image

Gebrauchsanweisung / Instruction for Use

Digitales Hörsystem für Brillen

Digital hearing system for spectacles

Summary of Contents for pan BiCROS

Page 1: ...Gebrauchsanweisung Instruction for Use Digitales H rsystem f r Brillen Digital hearing system for spectacles...

Page 2: ......

Page 3: ...geschablone q Adapterring q BHM Stiftsetzer q Buchsenabdeckung 3x Symbole Hersteller CE Zeichen nicht im Hausm ll entsorgen Gebrauchsanweisung beachten Achtung 20 C 60 C Temperatur w hrend des Transpo...

Page 4: ...verl sslicher Partner sein In den ersten Tagen der Benutzung Ihres neuen H rsystems stehen die Handhabung des Ger tes und die Gew hnung an die neuen Klangeindr cke im Vordergrund Die Verst rkung und...

Page 5: ...her Sprachformen verzichtet S mtliche Personenbezeichnungen gelten gleicherma en f r beiderlei Geschlecht Weitere aktuelle Informationen finden Sie auf der Homepage www bhm tech at Diverse individuell...

Page 6: ...s H rsystem sollte keinesfalls verwendet werden wenn der Verdacht besteht dass es nicht einwandfrei funktioniert oder besch digt ist speziell das Batteriefach Setzen Sie das H rsystem keinen berm i ge...

Page 7: ...0 Ohrsimulator EN 60118 7 2 cm3 Kuppler High Power H rer Normal Power H rer High Power H rer Normal Power H rer Betriebsspannung 1 30 V 1 30 V Ausgangsschalldruckpegel 90 dBSPL Eingang Max 1600 Hz HFA...

Page 8: ...Instructions for Use 8 Gebrauchsanweisung Programmwahltaster 2 Batteriefach 3 Programmierbuchse 4 H rerschlauch 5 Externer H rer 6 Ohrpassst ck 7 Mikrofone Teile des H rsystems Symbolabb 1 6 7...

Page 9: ...terrichten Um die Sicherheit und Funktionalit t des H r systems zu gew hrleisten darf ausschlie lich Zubeh r von BHM verwendet werden Der externe H rer Der f r Ihre Anforderungen ausgew hlte H rer und...

Page 10: ...den Sie sich an Ihren H rger te Akustiker oder Arzt Einlegen bzw Wechseln der Batterie Wenn Sie eine Batterie einsetzen achten Sie darauf dass der Pol der Batterie auf der gleichen Seite wie das Zeich...

Page 11: ...t zu halten Nachdem eine neue Batterie eingesetzt wurde sind alle Funktionen automatisch wie der hergestellt Ein Verschlucken der Batterie gef hrdet Ihre Gesundheit und kann schwere Ver letzungen bis...

Page 12: ...n niemals zusammen mit z B Medikamenten aufbewahren Suchen Sie im Falle dass eine Batterie verschluckt wurde unverz glich einen Arzt auf Batterien f r Kinder unerreichbar aufbewahren Achten Sie auf ei...

Page 13: ...ik Film St rger usche Windger usche In Abh ngigkeit dieser Einstufung werden die Parameter des H rsystems stets so konfigu riert dass ein optimaler H rkomfort und eine op timale Sprachverst ndlichkeit...

Page 14: ...Instructions for Use 14 Gebrauchsanweisung Programm Best tigungssignal Beschreibung der H rsituation 1 1 maliger Piepton 2 2 maliger Piepton 3 3 maliger Piepton 4 4 maliger Piepton...

Page 15: ...ormal telefonieren indem Sie den Tele fonh rer auf Ihre Ohrmuschel halten Wenn Ihr H rsystem mit einem High Power H rer mit Ohrpassst ck oder individueller Otoplas tik angepasst wurde muss ggf eine op...

Page 16: ...rvorganges Vor dem Programmieren Vor der Programmierung ist die Buchsenab deckung zu entfernen Symbolabb 8 Entfernen Sie die Buchsenabdeckung mithilfe einer Pinzette Unter der Abdeckung wird die Progr...

Page 17: ...nitus und H rverlust vertraut ist eingesetzt werden Wichtige Informationen f r Benutzer des Tinnitus Maskers Diese Anweisungen enthalten Informationen zum Tinnitus Masker dessen erzeugtes Rauschen ein...

Page 18: ...in Bezug auf die maximale t gliche An wendungsdauer Die Lautst rke Ihres Tinnitus Maskers darf Ihnen niemals unangenehm sein Akustiker oder Arzt diese Funktion f r Sie frei schalten aktivieren Der Tin...

Page 19: ...t einer Fehlfunktion des Ger tes zu minimieren In Verbindung mit dem Tragen eines Tinnitus Maskers gibt es mitunter potenzielle Risiken zu beachten Unter anderem kann es zu einer Verschlechterung der...

Page 20: ...onderentsorgung zu Ihr H rger te Akustiker oder Arzt wird Ihnen dabei gerne behilflich sein muss das Ger t regelm ig gereinigt und gewartet werden Verschmutzungen K rperschwei und Feuch tigkeit sollte...

Page 21: ...rsystems im Beisein von S uglingen Kleinkindern Kindern oder geistig beeintr chtigten Per sonen Batterien niemals zusammen mit Medikamentenaufbewahren SuchenSieim Entsorgung des H rsystems Ihr H rsys...

Page 22: ...on Ihrem H rsystem entfernt werden Legen Sie beim Duschen oder bei der Kopf w sche in der Sauna oder im Dampfbad Ihr H rsystem unbedingt vorher ab Falle dass eine Batterie verschluckt wurde unverz gli...

Page 23: ...s beeinflussen oder ungew hnliche T ne hervorrufen Suchen Sie einen Arzt auf falls sich Haut irritationen zeigen F r besonders hygienische und hautscho nende Reinigung empfehlen wir im Fach handel erh...

Page 24: ...das H rsystem selbst zu ffnen bzw zu reparieren Unsachgem e Behandlung f hrt zum Erl schen der Garantie und der Gew hrleistung Regelm ige Wartung und berpr fung bei Ihrem H rger te Akustiker oder Arz...

Page 25: ...richtig herum ein Reinigung des Ohrpassst ckes Austauschen des Cerumenfilters H rsystem ist zu leise Ohrpassst ck sitzt zu locker Verstopftes Ohrpassst ck H rverlust hat sich ver ndert Zu viel Cerume...

Page 26: ...ren H rger te Akustiker oder Arzt Fragen Sie Ihren H rger te Akustiker oder Arzt Klang ist verzerrt Schwache Batterie Schlecht sitzendes Ohrpassst ck Das H rsystem ist besch digt Die H rsystemeinstell...

Page 27: ...CROS q Installation template q Adapter ring q BHM pin setting tool q Socket cover 3x Symbols Manufacturer CE marking Do not dispose of in household waste Please read Instruction for Use Warning 20 C 6...

Page 28: ...partner for many years to come The first few days of using a new hearing sys tem will focus primarily on familiarising your self with the device and becoming accustomed to the new sound impressions T...

Page 29: ...user s residual hearing For additional current information please visit www bhm tech at Various individual settings such as the sound ing of warning tones or their volume is the responsibility of your...

Page 30: ...f the following in formation as relates to the person who will Please check that the hearing system functions and is in proper condition before use The hearing system must in no way be used if there i...

Page 31: ...er Normal Power Receiver High Power Receiver Normal Power Receiver Operating voltage 1 30 V 1 30 V Output sound pressure level 90 dBSPL input Max 1600 Hz HFA 130 dBSPL 123 dBSPL 127 dBSPL 119 dBSPL 11...

Page 32: ...2 Instruction for Use Program selection button 2 Battery compartment 3 Programming connector 4 Receiver tube 5 External receiver 6 Earpiece 7 Microphones Hearing system components Symbolic image 1 6 7...

Page 33: ...th comprehensive instruction on how to han dle your pan hearing system and accessories In order to guarantee the safety and function ality of the hearing system only accessories from BHM must be used...

Page 34: ...battery first before inserting the new one Only use zinc air batteries in size 312 Remove the adhesive strip from the positive terminal Then wait the amount of time stipulated by the manufacturer bef...

Page 35: ...by the hearing care professional Never store batteries alongside for example medicines If you have swallowed a battery please seek medical at tention immediately Always store batteries out of reach o...

Page 36: ...ur hearing system your hearing care professional can activate a switch on delay This allows you to apply the hearing system s external receiver comfortably in the ear without any experiencing disturbi...

Page 37: ...If your hearing system has been adapted with a high power receiver with earpiece or individual otoplasty it may be necessary to find an optimum position of the telephone The following tips should hel...

Page 38: ...38 Instruction for Use Programme Confirmation signal Description of hearing situation 1 1 beep 2 2 beeps 3 3 beeps 4 4 beeps...

Page 39: ...image 8 Use a pair of tweezers to remove the socket cover Under the cover the programming socket to which the programming cable can be connected becomes visible Symbolic image 9 way Slide the telephon...

Page 40: ...it back on the programming socket Carefully press the cover back into the pro gramming socket Ensure that the cover is firmly seated on the programming socket Symbolic image 10 Insert the programming...

Page 41: ...as headaches nausea dizziness or heart palpitations or experience a decrease in auditory function such as decreased loudness tolerance worsening Tinnitus Masker pan Ti only The Tinnitus Masker is a t...

Page 42: ...ing of tinnitus and or a possible change in hearing thresholds Important information related to tinnitus The Tinnitus Masker generates sounds that are used as part of your personalized temporary tinni...

Page 43: ...in structions at all times as otherwise there can be no guarantee claim and no warranty repairs can be carried out After use Maintenance and cleaning Please be advised by your hearing care pro fessio...

Page 44: ...according to individual requirements and upon instruction by your hearing care professional This hearing system is able to emit signals at a high volume In order to prevent pos sible hearing damage t...

Page 45: ...tems will no longer function properly if for example battery power is running out This poses a particular danger in traffic or must be adapted by a qualified hearing care professional Never try to cha...

Page 46: ...connect devices that comply with the relevant international safety standards when you are in any other way dependent on warning signals Incorrect handling may cause the battery to leak and endanger y...

Page 47: ...y and is therefore harmless to your hearing system This radiation can however affect the sound quality of your hearing system short term or produce unusual tones Your mobile phone may influence the so...

Page 48: ...period for the hearing system the warranty is two years Please go to your hearing care professional if you wish you have your hearing system maintained If your BHM hearing system does not work it must...

Page 49: ...y with a new one Insert the battery correctly Clean the earpiece Replace the cerumen filter Hearing system is too quiet Earpiece has been placed too loosely Blocked earpiece Hearing loss has changed T...

Page 50: ...ce Consult your hearing care professional Consult your hearing care professional Sound is distorted Weak battery Earpiece not placed correctly The hearing system is damaged The hearing system settings...

Page 51: ......

Page 52: ...ormance 20 C 60 C 10 95 BHM Tech Produktionsgesellschaft mbH Grafenschachen 242 7423 Grafenschachen Austria www bhm tech at nach Medizinprodukterichtlinie 93 42 EWG RoHS 2011 65 EU RED 2014 53 EU Qual...