1.

L18P Lubricator

Manual, One Shot

Operation

The L18P Lubricator is a spring return piston pump. Pushing the operating handle down raises a 
piston and compresses a spring. Releasing the handle discharges oil into the system. Oil viscosity 
does not affect discharge volume, but may affect system pressure.

Technical Data

Reservoir Capacity

1 litre

Lubricator Inlet Filter

40 micron particle separation

Discharge Pressure

65 psi maximum

Factory Discharge Setting

18cc

Discharge Volume Per Stroke

6 to 18cc infinitely adjustable

Viscosity Range

150 to 8,000 SSU at operating temperature

Notes Regarding Use

1.  Lubricator inlet filter should be inspected periodically and cleaned/replaced as required.
2.  Discharge pressure will decrease as discharge volume decreases and the number of meter 

units in the system increases.

System & Limitations

Use Type F meter units. Do not exceed 70 meter units. To calculate system flow (ø), refer to Bijur 
Engineering Manual. Do not exceed figures shown below.

Maximum Permissible Total System Flow (o)

CC Per Shot

6

9

12

15

18

Stroke Setting

15/64"

23/64"

31/64"

19/32"

23/32"

Met

er U

nits (#)

15

1750

2400

2900

3500

20

1500

1800

2200

2600

3400

25

1230

1450

1700

2000

2500

30

950

1150

1400

1700

2100

40

780

930

1100

1300

1600

50

640

770

920

1100

1400

60

570

680

810

960

1200

70

500

600

720

860

1080

Startup Instructions

Fill reservoir; operate lubricator until oil flows freely at all bearings.