1.
L18P Lubricator
Manual, One Shot
Operation
The L18P Lubricator is a spring return piston pump. Pushing the operating handle down raises a
piston and compresses a spring. Releasing the handle discharges oil into the system. Oil viscosity
does not affect discharge volume, but may affect system pressure.
Technical Data
Reservoir Capacity
1 litre
Lubricator Inlet Filter
40 micron particle separation
Discharge Pressure
65 psi maximum
Factory Discharge Setting
18cc
Discharge Volume Per Stroke
6 to 18cc infinitely adjustable
Viscosity Range
150 to 8,000 SSU at operating temperature
Notes Regarding Use
1. Lubricator inlet filter should be inspected periodically and cleaned/replaced as required.
2. Discharge pressure will decrease as discharge volume decreases and the number of meter
units in the system increases.
System & Limitations
Use Type F meter units. Do not exceed 70 meter units. To calculate system flow (ø), refer to Bijur
Engineering Manual. Do not exceed figures shown below.
Maximum Permissible Total System Flow (o)
CC Per Shot
6
9
12
15
18
Stroke Setting
15/64"
23/64"
31/64"
19/32"
23/32"
Met
er U
nits (#)
15
1750
2400
2900
3500
20
1500
1800
2200
2600
3400
25
1230
1450
1700
2000
2500
30
950
1150
1400
1700
2100
40
780
930
1100
1300
1600
50
640
770
920
1100
1400
60
570
680
810
960
1200
70
500
600
720
860
1080
Startup Instructions
Fill reservoir; operate lubricator until oil flows freely at all bearings.