BIJUR DELIMON INTERNATIONAL
(919) 465 4448
LOCAL
(800) 631 0168
TOLL-FREE
(919) 465 0516
FAX
WWW.BIJURDELIMON.COM
2250 Perimeter Park Dr., Suite 120
Morrisville, NC 27560
36734 • R0
04/17
1
V5B Lubricator
Automatic Continuous
Operation
The V5B Lubricator consists of a motor-driven gear pump with a controlled constant volume
discharge. The fully automatic lubricating system is preset by the machine manufacturer for best
operation. Discharge volume may be adjusted by turning the bypass valve counter-clockwise to
reduce the pressure and thus automatically reduce the amount of oil, or by closing valve to increase
pressure and oil flow.
Technical Data
Motor
1/20 hp, NEMA Frame L330, totally enclosed, non-ventilated*
Voltage
115 VAC
Frequency
60/50 Hz
Speed
1725/1425 rpm (60/50 Hz)
Start Amperage
2.3/2.5 amp
Run Amperage
0.78/0.67 amp (60/50 Hz)
Maximum Ambient Temperature
104°F (40°C)
* Also available with totally enclosed fan cooled motor.
Discharge Adjustment
Lubricator is preset with bypass valve closed for maximum discharge of 132cc per minute
(110cc with a 50 cycle motor). With lubricator at normal operating temperature on machine, desired
discharge volume is obtained by adjusting the bypass to pre-calculated pressure on system pressure
gauge (see
Bijur Engineering Manual
). Pressure is limited internally to 130 psi by a relief valve.
System & Limitations
Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature.
See
Bijur Engineering Manual
for system limitations.
Startup Instructions
1. Fill reservoir with oil.
2. Start machine and see that oil flows at all bearings.
Use clean oil only of the type and viscosity
recommended by machine manufacturer.
Replace filter group annually.