background image

BIJUR DELIMON INTERNATIONAL

(919) 465 4448 

LOCAL   

 

(800) 631 0168 

TOLL-FREE    

(919) 465 0516 

FAX   

 

WWW.BIJURDELIMON.COM

2250 Perimeter Park Dr., Suite 120    
Morrisville, NC 27560

36734  •  R0 

04/17

1

V5B Lubricator

Automatic Continuous

Operation

The V5B Lubricator consists of a motor-driven gear pump with a controlled constant volume 
discharge. The fully automatic lubricating system is preset by the machine manufacturer for best 
operation. Discharge volume may be adjusted by turning the bypass valve counter-clockwise to 
reduce the pressure and thus automatically reduce the amount of oil, or by closing valve to increase 
pressure and oil flow.  

Technical Data

Motor

1/20 hp, NEMA Frame L330, totally enclosed, non-ventilated*

Voltage

115 VAC

Frequency

60/50 Hz

Speed

1725/1425 rpm (60/50 Hz)

Start Amperage

2.3/2.5 amp

Run Amperage

0.78/0.67 amp (60/50 Hz)

Maximum Ambient Temperature

104°F (40°C)

* Also available with totally enclosed fan cooled motor.

Discharge Adjustment

Lubricator is preset with bypass valve closed for maximum discharge of 132cc per minute  
(110cc with a 50 cycle motor). With lubricator at normal operating temperature on machine, desired 
discharge volume is obtained by adjusting the bypass to pre-calculated pressure on system pressure 
gauge (see 

Bijur Engineering Manual

). Pressure is limited internally to 130 psi by a relief valve.

System & Limitations

Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature.  
See 

Bijur Engineering Manual 

for system limitations.

Startup Instructions

1.  Fill reservoir with oil.
2.  Start machine and see that oil flows at all bearings.

 

Use clean oil only of the type and viscosity 
recommended by machine manufacturer.

 

Replace filter group annually.

Summary of Contents for V5B

Page 1: ...725 1425 rpm 60 50 Hz Start Amperage 2 3 2 5 amp Run Amperage 0 78 0 67 amp 60 50 Hz Maximum Ambient Temperature 104 F 40 C Also available with totally enclosed fan cooled motor Discharge Adjustment Lubricator is preset with bypass valve closed for maximum discharge of 132cc per minute 110cc with a 50 cycle motor With lubricator at normal operating temperature on machine desired discharge volume i...

Page 2: ...p to the top plate 2 Turn the lubricator unit upside down 3 Remove the two M4 SHC screws holding the gear pump to the downspout and remove the gear pump and inlet gear pump adapter Remove the three 8 32 socket cap screws holding the downspout onto the motor and lift the downspout clear from the motor Carefully remove the motor driveshaft and coupling 4 Replace the motor and carefully re assemble t...

Page 3: ... generation V5B Pump Motor 60651 will not fit the pervious generation D2559 reservoir Service Parts 60443 Item Description Part 1 Reservoir Assembly D2559 1 2 Pump Motor Assembly 60651 3 Gasket B6903 1 4 Lock Washer M5 X4 HW310 5 Screw HD 10 32 X4 HS123 Service Parts 60651 Item Description Part 1 Gasket B6903 1 2 Driveshaft Sleeve 25931 3 O Ring X2 34630 4 Gear Pump 25937 1 5 Motor Driveshaft 2917...

Page 4: ...M5 X4 HW310 5 Screw HD 10 32 X4 HS123 Service Parts 70617 Item Description Part 1 Gasket B6903 1 2 Driveshaft Sleeve 25931 3 O Ring X2 34630 4 Gear Pump 25937 1 5 Motor Driveshaft 29170 6 Relief Valve 130 PSI B6898 7 Copper Washer 20913 3 8 Brass Plug M12X1 23422 9 Check Valve 2 LB B5880 10 Coupling 1 8NPTF B6539 11 Bypass Adjustment Screw 23958 12 O Ring HO412 13 Locking Nut 23957 14 Motor 115VAC...

Page 5: ...60 36734 R0 04 17 5 Dimensional Schematics Part A 60443 11 35 288mm 70618 12 5 317mm 1 8 NPTF F OUTLET BYPASS VALVE A SETTLING CHAMBER FLUSH PLUG 1 2 NPT F ALTERNATE OIL RETURN 1 2 NPT F OIL RETURN FILLER CAP RESERVOIR DRAIN PLUG OIL LEVEL GAUGE MOUNTING HOLES 1 4 20 1 2 DEEP 4 HOLES 13 32 DIA FOR ALTERNATE MOUNTING 2 10 5 6 5 4 5 Measurements shown in inches ...