Binks SV50 HVLP
GraVity Feed SPray Gun
& toucHuP Gun
Replaces
Part Sheet
77-2891
Part
Sheet
77-2891R
ATTENTION!
READ BEFORE ATTACHING THE AIR HOSE
HVLP AIR SUPPLY REQUIREMENTS
FULL SIZE GUN:
30 PSI inlet pressure provides 10 PSI at the air cap. Consumes 12 CFM.
TOUCHUP GUN:
30 PSI inlet pressure provides 10 PSI at the air cap. Consumes 8 CFM.
NOTE: USE 5/16" OR LARGER I.D. AIR HOSES
SPECIFICATIONS
Max. Air Pressure:
100psi
For HVLP Compliance: 30 psi inlet pressure delivers
10 psi air cap pressure
Gun Body:
Cast Aluminum
Fluid Path:
Aluminum
Fluid Nozzle:
Stainless Steel
Fluid Needle:
Stainless Steel
Air Inlet Size:
1/4" NPS(M)
OPERATION ANd MAINTENANCE INSTRuCTIONS
Your new SV50 Gravity Feed Spray Gun and Gravity Feed
Touchup Gun are exceptionally rugged in construction and
built to stand up under hard, continuous use. However, like
any other fine precision instruments, their most efficient
operation depends on a knowledge of their construction,
operation, and maintenance. Properly handled and cared
for, they will produce beautiful, uniform finishing results
long after other spray guns have worn out.
SET-uP FOR SPRAyINg (Figure 1)
CONNECTINg guN TO AIR HOSE
Air should be supplied by a suitable length of 5/16"
diameter air hose fitted with a 1/4 NPS(f) connection to
the base of the gun handle. For hose lengths over 50',
use 3/8" hose.
CONNECTINg gRAvITy FEEd CuP TO guN
Screw the cup into the spray gun fluid inlet. Fill the
cup with filtered paint.
If desired, attach air adjusting valve with gauge and/or
quick disconnect to air inlet, then attach hose. Spray test
and adjust air pressure, fan size, and fluid flow as
required. Recommended spray distance is 6-8 inches.
Figure 1
WarninG
Servicing the gun while pressurized could result in compo-
nents or material exiting the gun at high velocity, possibly
resulting in personal injury or damage to the spray gun.
Before removing any components from the spray gun, shut
off air pressure and drain material from the paint cup.
!
gravity
Feed
Cup
Fluid
Inlet
gravity
Feed
Srpay gun
Fan
Size
Control
Material
Flow
Control
Air Hose
WarninG
A failure resulting in injury or
damage may be caused by
pressure beyond top of scale,
excessive vibration or pressure
pulsation, excessive instrument
temperature, corrosion of the
pressure containing parts or
other misuse of the air adjusting
valve with gauge.
!
Summary of Contents for sv50
Page 6: ...6 NOTES...
Page 7: ...NOTES 7...