background image

BITMAIN

 S4+

 Server

 Manual

 

Summary of Contents for S4+

Page 1: ...BITMAIN S4 Server Manual ...

Page 2: ...iew 3 2 Features 3 3 Connect to Server 3 4 Server Configuration 6 4 1 Pool Setting 6 4 2 Frequency Modification 6 5 Server Status 7 6 System Configuration and status 7 6 1 System Upgrading 7 6 2 Password Modification 8 6 3 Software Version Checking 9 6 4 Restore Initial Setting 9 ...

Page 3: ...asier for customers to set up Please note 1 The included PSU cannot be used in countries with a mains power voltage lower than 205V The PSU will not start below this voltage 2 Power line is not included please find one with at least 10A in your local market 2 Features Ideal Hash Rate GH s 2570 Default chip clock M 200 Estimate power on wall W 1480 Estimate efficiency on wall J GH 0 58 Dimensions m...

Page 4: ...e file and double click IPReporter exe The Shelf Step Position options are suitable for farm servers to mark the location of the servers For home servers it can be left as default Then click Start 2 Press the raised IP Reporter button on right top corner of panel next to the green and red LED light you ll hear a beep sound 3 Check your PC you ll see the IP address showing in the pop up window ...

Page 5: ... of 10 Page 5 10 Step 2 Enter the IP address provided into your WEB browser and proceed to login using root for both the username and password In the Network section you can assign a Static IP address if you like Click Save Apply after modifying it ...

Page 6: ...ng pools with decreasing priority from the first pool pool 1 to the third pool pool 3 The pools with low priority will only be used if all higher priority pools have gone offline 4 1 2 When Stop running when temperature is over 95 is checked the server will stop mining when the temperature exceeds 95 to protect the server If it s unchecked the server will still mine even in high temperature Click ...

Page 7: ...status of your server on status page below ASIC Number of chips detected in the chain Frequency ASIC frequency setting Temp Temperature centigrade ASIC status o stands for OK x stands for error 6 System Configuration and status 6 1 System Upgrading You can upgrade The server s firmware on System Upgrade page ...

Page 8: ...graded and download the software During the upgrade process you need to wait patiently and must keep power on otherwise the server can only be fixed with returned to factory You will see below screenshot after upgrading successfully Clicking the Reboot button will restart the server so it can load the new software Clicking Go Back will keep the server mining before switching to the new software wh...

Page 9: ...rsion displays the date of the firmware your server use In the example below the server is using 20150402 firmware 6 4 Restore Initial Setting There is a Reset button on the left hand side of the IP Reporter button press and hold the button for 5 seconds in order to restore to the default settings and reboot The red LED will flash once every 15 seconds automatically if the reset is operated succes...

Page 10: ...S4 Server Manual Last updated 4 22 2015 Page 10 of 10 Page 10 10 ...