background image

 BXEH60003GB

www.blackanddecker.co.uk

Summary of Contents for BXEH60003GB

Page 1: ...BXEH60003GB www blackanddecker co uk ...

Page 2: ...ENGLISH Original instructions 2 2 1 6 4 3 5 What s in the box Instruction Manual Dehumidifier Features 1 Air outlet 2 Control panel 3 Air inlet 4 Filter 5 Water tank 6 Handle ...

Page 3: ...of fire electric shock personal injury and material damage Using Your Appliance Please read the operating instructions carefully before using your appliance for the first time Check that the voltage of the main circuit corresponds with the rating of the appliance before operating Children shall not play with the appliance Do not let the cable hang over the edge of a table or counter or let it come...

Page 4: ...appliance is used near pets Do not allow the cord to become twisted After Use While cleaning DO NOT use a wet cloth or use water on any part of the unit as this may cause a short circuit or electrical shock Keep this unit clean Do not allow objects to enter the ventilation opening as this may cause electric shock or damage to the unit Switch off the unit and then remove the plug from the socket wh...

Page 5: ...n windows as contact with rain and other natural elements could cause an electrical hazard Do not put heavy objects on the appliance Do not tip the unit on its side Never insert any other object into the unit body to avoid any hazard or unit failure Do not put the unit close to heat generating devices or near flammable and dangerous materials If the supply cable is damaged it must be replaced by t...

Page 6: ...e in a room with a floor area of less than 4m2 Be aware that the refrigerant may be odourless and that leaks may not be detectable by smell ALWAYS take care to comply with national gas regulations Keep ventilation openings clear of obstruction Store the appliance in a well ventilated area where the room size corresponds to the room area specified for operation Any person who is involved with worki...

Page 7: ...ch the appliance off and remove the plug from the socket Features 1 Air outlet 2 Control panel 3 Air inlet 4 Filter 5 Water tank 6 Handle Use About the Controls Dry clothes Normal Operation Continuos Operation Ventilation Sleep Mode Operation and Efficiency This appliance operates in temperatures between 5 32 C Defrosting operation The evaporator in the dehumidifier may defrost automatically if it...

Page 8: ...storing Dehumidification Modes There are 4 modes to select from Normal dehumidification adjustable fan speed and adjustable humidity Continuous dehumidification a set low fan speed and humidity is not adjustable Ventilation mode adjustable fan speed and humidity is not adjustable Drying mode a set high fan speed and set humidity is not adjustable Press the mode button to cycle through the options ...

Page 9: ... The drainage hose should not be installed outdoors at low temperatures Drainage Manually When the water tank is full the water full indicator is will illuminate and the unit will stop working Pull out the water tank and pour away the water Replace the water tank The dehumidifier will restart Note Before putting in the water tank please ensure the float inside it moves freely Cleaning and maintena...

Page 10: ...ew plug Connect the blue lead to the neutral terminal If the product is class I earthed connect the green yellow lead to the earth terminal Note If your product is class II double insulated only 2 wires in the cord set no connection is to be made to the earth terminal Follow the fitting instructions supplied with good quality plugs Any replacement fuse must be of the same rating as the original fu...

Page 11: ...such a manner that it may lead to the risk of fire or explosion All possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which refrigerant can possibly be released to the surrounding space Prior to work taking place the area around the equipment is to be surveyed to make sure that there are n...

Page 12: ...serve the purpose of preventing the ingress of flammable atmospheres Replacement parts shall be in accordance with the manufacturer s specifications 11 Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use Intrinsically safe co...

Page 13: ...ging but prior to commissioning A follow up leak test shall be carried out prior to leaving the site 14 Decommissioning Before carrying out this procedure it is essential that the technician is completely familiar with the equipment and all its detail It is recommended good practice that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall b...

Page 14: ... is in satisfactory working order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant waste transfer note arranged Do not mix refrigerants in recovery un...

Page 15: ...s please contact our customer services team The product must be installed and used in accordance with the instructions contained in this instruction guide It must be used only for domestic purposes It does not cover wear and tear damage misuse or consumable parts This guarantee is valid in the UK and Republic of Ireland For all customer service enquires please contact us below RKW Sutton House Ber...

Page 16: ...11 2020 ...

Reviews: