BEFORE INSTALLING THE  BW-1600

• DO read through this installation manual.
• DO NOT install the alarm brain in an engine compartment.
• The alarm may arm itself when power is first connected.This is a normal condition.

ITEMS SUPPLIED WITH THE  BW-1600

BW-1602

Receiver and Control Module

BW-260P

Valet/Override Switch

BW-385

2-Button, Code Learning 

BW-180P

LED Status Indicator

Transmitters (2)

BW-12016

Wiring Harness, Fuseholder, & Fuse

MTS-20W

Six-tone, soft chirp, 120 dB Siren

BW-296P

Dual Zone Electronic Shock Sensor

BW-12016DL

Door Lock Harness

OPTIONAL ACCESSORIES

Radar Field Sensor.........................................

MAS-2

Backup Battery .......................................................

BW500

Window Rollup.............................................

WRM-2

Remote Starting.................................................

RAS-101

Power Door Lock........................................

PDL-50

Trunk Release ........................................................

TR-100

Relay......................................................................

SPDT

Relay Socket ........................................................

BRS-003

5-wire Door Lock relay & socket .

BRS-008PR

Glass Sensor .......................................................

BWS-200

(+) Door Lock Inverter.............................

BW-345

SPECIFICATIONS

Operating voltage ...............+12 VDC Neg. Ground
Code Learning ......................................3 Codes Max.
Current consumption .........5 mA (max) disarmed.
Siren output drive ......................................3 Amperes
Automatic reset........................................60 seconds.
Door Lock/Unlock Output ...................(-) 500 mA.
Channel 2 Output Drive ........(-) 500 mA variable.

Remote control transmit freq.............................310 mHz.
Passive arming delay ............................30 Seconds approx.
Auxiliary output drive..........................250 mA maximum.
Flashing output drive ............................10 Amp maximum.
Trigger inputs..............................................1) Neg. pnswtch.
1) Pos. pnswtch. 1) Neg. sensor or aux. pnswtch.

I N S T A L L A T I O N   M A N U A L

Please read this Black Widow manual carefully before attempting to install this system.

B

L

A

C

K

W

I

D

O

W

I N S T A L L A T I O N   M A N U A L

Summary of Contents for BW-1600

Page 1: ...ote Starting RAS 101 Power Door Lock PDL 50 Trunk Release TR 100 Relay SPDT Relay Socket BRS 003 5 wire Door Lock relay socket BRS 008PR Glass Sensor BWS 200 Door Lock Inverter BW 345 SPECIFICATIONS Operating voltage 12VDC Neg Ground Code Learning 3 Codes Max Current consumption 5 mA max disarmed Siren output drive 3 Amperes Automatic reset 60 seconds Door Lock Unlock Output 500 mA Channel 2 Outpu...

Page 2: ...s such as radiators exhaust manifolds and turbochargers Mount it in an area where it will not be in the way for mechanics and so that it cannot be easily reached from below the vehicle Mount it so that its opening points down to prevent it from collecting water snow or ice Connect its BLACK wire to a good clean GROUND point and its RED wire to the BROWN wire of the main harness 5 Mount the BW 296P...

Page 3: ...K RELAY YELLOW WIRE FROM ALARM GRN BK WIRE FROM ALARM 12V FUSED CONSTANT LOCK UNLOCK If the power trunk re lease requires a positive pulse to operate use this circuit 2nd CHANNEL AUXILIARY BROWN WIRE 12V POSITIVE OUT TO TRUNK 12V REVERSE POLARITY DIRECTLY TO AD ON ACTUATORS GROUND GROUND REVERSE POLARITY USING FACTORY SYSTEMS TRUNK RELEASE CIRCUIT DIAGRAM SWITCH ACTUATOR LOCK UNLOCK For these reve...

Page 4: ...CTORS PLUG COLOR FUNCTION 1 Blue Valet Override Plug in the Blue 2 pin connector for theVALET switch Switch to the Blue receptacle on the circuit board 2 PIN LED PLUG IN CONNECTORS PLUG COLOR FUNCTION 1 Red LED Plug in the Red 2 pin connector for the LED to the Red receptacle on the circuit board 3 PIN DOOR LOCK PLUG IN CONNECTOR WIRE COLORS FUNCTION 1 Green Door Negative output pulse to door LOCK...

Page 5: ...DIODE OPTIONAL 12V OUTPUT 30 87 87A 86 86 NEGATIVE DOOR LOCK OUTPUT SEE PAGE 5 NEGATIVE DOOR UNLOCK OUTPUT SEE PAGE 5 RECEIVER MODULE HARNESS OPTIONAL STARTER INTERRUPT RELAY 3rd CHANNEL DOMELIGHT TO STARTER WHITE RED BLACK ORANGE 2nd CHANNEL BLACK GROUND NOT USED BY THIS MODULE JUMPER SETTINGS Jumper 1 OFF 3 Second pulse Jumper 1 OFF No auto lock with ignition Ignition 12V MUST NOT DROP OUT durin...

Page 6: ...voltage changes Repair and or rewire as needed Alarm will arm from Dipswitch 4 is off Set dipswitch 4 to ON transmitter but will not passively arm Remote Control does Defective Remote Control Bad Replace Remote Control or its not arm or disarm battery Antenna wire is battery Un ground antenna alarm grounded Valet does not work Bad switch or wrong activation Repair or replace switch or check sequen...

Page 7: ... purchase ship defective unit prepaid to Black Widow Division DLC Inc along with 20 00 U S 30 00 Canadian cashier s check or money order to cover cost of handling Proof of purchase by the original owner must accompany warranty request before service is rendered This warranty covers normal use It does not cover damage from alteration misuse abuse accident improper installation or maintenance Warran...

Reviews: