background image

THE POND MASTERS

GUIDE TO

KOI AIR

25/50/65

Koi Air Instruction Leaflet 2.qxd  30/3/06  13:51  Page 1

Summary of Contents for Koi Air 25

Page 1: ...THE POND MASTERS GUIDE TO KOI AIR 25 50 65 Koi Air Instruction Leaflet 2 qxd 30 3 06 13 51 Page 1...

Page 2: ...oxygen in the pond and reduce carbon dioxide levels thus aiding in preventing the pond from stagnating by injecting air into the water Additionally by placing air stones directly into the filter chamb...

Page 3: ...aphragm Koi Air 25 10 Replacing the diaphragm Koi Air 50 65 11 Troubleshooting 12 Troubleshooting and maximising performance 12 Faults Problems Procedure Inside back cover Consumer advice contact deta...

Page 4: ...8 see No 26 for outlet connector pipe No Name of part Code 26 Outlet connector pipe see No 25 for outlet connector pipe clip 27 8 x outlet valved metal air divider 1021012 28 Flapper valve chamber boa...

Page 5: ...YOUR KOI AIR 25 1 2 3 4 5 17 16 33 10 30 28 31 9 33 10 11 29 12 13 29 18 14 15 14 29 12 29 13 11 10 9 31 10 28 30 22 33 33 23 21 20 19 23 24 6 3 7 8 27 25 26 25 22 Koi Air Instruction Leaflet 2 qxd 30...

Page 6: ...nector pipe 1021135 28 Outlet connector pipe see No 27 for replacement code No Name of part Code 29 Koi Air 50 12 x outlet valved metal air divider 1021029 Koi Air 65 18 x outlet valved metal air divi...

Page 7: ...AIR 50 65 1 2 3 4 5 17 16 35 23 24 30 9 31 10 35 23 24 11 32 12 32 13 18 14 15 14 12 13 11 24 10 31 9 22 35 23 35 23 21 20 19 25 26 32 32 24 30 6 33 34 7 8 29 27 28 27 22 Koi Air Instruction Leaflet...

Page 8: ...MUST BE EARTHED A Residual Current Device RCD also known as the Residual Current Circuit Breaker RCCB with a tripping current not exceeding 30mA must be installed in the supply circuit A means of disc...

Page 9: ...formance of the pump over time therefore it is necessary to replaces air stones every twelve months as a minimum or more frequently depending on the cleanness of the air pumps environment IMPORTANT If...

Page 10: ...ir pump ensure it is isolated from the mains electricity supply Replacing the Outlet Foams Step by step guide for Koi Air 25 See Diagram 1 Remove the air filter cover part 1 2 Remove the 4 screws from...

Page 11: ...the diaphragm section 10 Replacing the Flapper Valves Step By Step guide for Koi Air 50 65 See Diagram 1 Remove the air filter cover part 1 2 Remove the 4 screws from the air pump base part 7 and rem...

Page 12: ...aphragm from the magnet frame part 15 7 Remove the diaphragm part 12 from the base ring Then remove the diaphragm backboard part 14 and the Teflon washer part 32 8 Place the new diaphragm into the bas...

Page 13: ...agm base ring part 13 can be used to pull the diaphragm from the magnet frame part 15 7 Remove the diaphragm part 12 from the base ring Then remove the diaphragm backboard part 14 and the Teflon washe...

Page 14: ...flapper valves see section 9 I Check diaphragms for wear and tear and replace if needed see sections 10 11 I Check and replace the air outlet filters in the base of the Koi Air see section 8 I Excess...

Page 15: ...one 01306 743747 Monday to Friday 10am to 4pm except Bank Holidays Times may vary Fax 01306 876712 E mail customercare interpet co uk GUARANTEE This Guarantee is offered as an extra benefit and does n...

Page 16: ...performance and value for all their customers This product excellence is demonstrated by Blagdon s award winning range of water gardening equipment As a result Blagdon s reputation for quality is unri...

Reviews: