background image

  0 / 29 

 
 

 

 
 
 
 

HDC  7016

   

16  DVB  S2  Tuner  /  2  ASI-IN  /  IP-IN  to  16  DVB-C  &  IP  out   

 
 
 

 

Data sheet and Instruction Manual 

 

 

 

V 1.1 

 

 

 

 

 

Summary of Contents for HDC 7016

Page 1: ...0 29 HDC 7016 16 DVB S2 Tuner 2 ASI IN IP IN to 16 DVB C IP out Data sheet and Instruction Manual V 1 1...

Page 2: ...ent TABLE OF CONTENT 1 INTRODUCTION 2 FEATURES 2 TECHN CAL DATA 3 LET S START WITH THE WEB INTERFACE 4 NETWORK SETTINGS 4 SAFE RESTORE BACKUP LOAD CONFIGS 5 LOGFILES 7 FIRMWARE UPGRADE 8 USERNAME PASS...

Page 3: ...stomers various requirements this device is also equipped with 2 ASI input ports which selected services can be mixed remultiplexed to the output channels The BLANKOM HDC 7016 is also characterized wi...

Page 4: ...ntrol for up to 8 satellites Multiplexing 16 multiplexers Maximum PID remapping 128 per input channel PID remapping automatically or manually Accurate PCR adjusting Generate PSI SI table automatically...

Page 5: ...he configuration of the device with any computer by connecting to the webserver by the 100BaseT NMS Port The user should ensure that the computer s IP address is different from other device s IP addre...

Page 6: ...many inputs into a STB can result in side effects If you need to select a Switch we recommend HP Procurve 2530 24G or 48G which are cost effective easy to configure can be trunked and supporting IGMP...

Page 7: ...IP Gateway User s Manual Author Ralf Riedel May 8 2020 Filename BlankomHDC 7016 ManualV1 1 RR docx Page 6 Safe Store the config bin file on your local PC Restoring this config Select the file and star...

Page 8: ...Page 7 confirm it please Remark Time Date Settings like in our other units is actually not implemented So the unit currently acquires this information from your logged in browser PC settings Future re...

Page 9: ...mHDC 7016 ManualV1 1 RR docx Page 8 Firmware upgrade Self explaining Username Password changing The default username PW can be changed to your needs Please make sure you do not lose it or a complete f...

Page 10: ...y connected to the Multiswitch 2nd looped from the first and so on until port 8 But that s way too much attenuation from loop to next RF IN If you setup the 6th Input 5th is toggling off and on again...

Page 11: ...R docx Page 10 Now we check Sat Pos 2 Hotbird 13 East by DiSEqC Assure before that all 13 18V settings from tuner 9 16 the splitter are off and DiSEqC is set to the same sattelite e Voila Now better t...

Page 12: ...iedel May 8 2020 Filename BlankomHDC 7016 ManualV1 1 RR docx Page 11 and 9 10 keeping as it was for Hotbird Signal quality of 1 8 are much better now Now that we have setup 16 SAT Inputs I have additi...

Page 13: ...2 Now we parse the inputs to collect each TS data If the parsing wasn t sufficient maybe increase the time out value for the demultiplexer to 100s or more depending on how many information might be de...

Page 14: ...not mess up with just IGMP Snooping in very cheap Layer 2 Switches You need full IGMP Support V2 3 as at least Layer 2 Switches better Layer 3 Otherwise you are passing the streams to all ports even i...

Page 15: ...RR docx Page 14 Passing all of Input 1to out TS1 isn t that simple Just some hints If the content is FTA not encrypted and no CI Flag set in the TS you can skip set the CA Filter and PID remapping is...

Page 16: ...f Riedel May 8 2020 Filename BlankomHDC 7016 ManualV1 1 RR docx Page 15 the PSI SI multiplexer already assigns LCN s to the NIT which is Logical Channel Number Sorting for your TV STB if it supports L...

Page 17: ...es by clicking right the service opens a popup Another hint we have some space left in this stream because I previous have set the output QAM channel to 256QAM 6900 SR let s check this for the others...

Page 18: ...ManualV1 1 RR docx Page 17 we stay DVB C Annex A C not using J83B ITU Annex B which is used in US and Korea Lets test the GAP changed to start all from 666MHz and used the first on reducing 8MHz so we...

Page 19: ...see the almost max data rate in a QAM DVB C Annex A C channel is 50 9 Mb s Because TV services usually do not use constant bitrates see Sports they increase bitrates per service We need to consider a...

Page 20: ...Manual Author Ralf Riedel May 8 2020 Filename BlankomHDC 7016 ManualV1 1 RR docx Page 19 Looks promising So we see we have 8Mbit space to less for another HD channel Now checking the CA Filter feature...

Page 21: ...BlankomHDC 7016 ManualV1 1 RR docx Page 20 That setting with Mux needs to be done if the output QAM exists by mixing different sources The DVB Tables need to be re created Useful for passing In to Out...

Page 22: ...an external PSI editor can be used and the NIT file uploaded to the unit Disadvantage If you change something you need to create correct and upload that again PID bypass can be used if some selective...

Page 23: ...anual Author Ralf Riedel May 8 2020 Filename BlankomHDC 7016 ManualV1 1 RR docx Page 22 no CA filter necessary neither PID remapping The easiest way to do DVB S 2 into QAM Setting up all 16 QAM channe...

Page 24: ...er to 16x DVB C IP Gateway User s Manual Author Ralf Riedel May 8 2020 Filename BlankomHDC 7016 ManualV1 1 RR docx Page 23 If you are muxing with IP MPTS Inputs you have to start action for every TS I...

Page 25: ...16x DVB S2 Tuner to 16x DVB C IP Gateway User s Manual Author Ralf Riedel May 8 2020 Filename BlankomHDC 7016 ManualV1 1 RR docx Page 24 and first use the tuner services than the IP ones...

Page 26: ...r s Manual Author Ralf Riedel May 8 2020 Filename BlankomHDC 7016 ManualV1 1 RR docx Page 25 Scrambling Select which and what to encrypt and connect the unit to the IP Address of the CA Server The val...

Page 27: ...we should adjust the QAM Channels according to the ITU Cenelec Channel line ups so that TV sets can easier tune by using the default channel lists Example starting with That s enough for 16 channels...

Page 28: ...ed nor expressed this includes also any warranties regarding the merchantability and fitness for a particular purpose IRENIS GmbH may improve this manual or make changes in the products described here...

Page 29: ...nualV1 1 RR docx Page 28 Contact IRENIS GmbH Hauptstr 29 31171 Nordstemmen Germany Phone 49 5069 4809781 IRENIS technical hotline VoIP 49 5069 4399 860 or 8601 Managing Director Dipl Ing Murad nol Com...

Reviews: