background image

INSTRUCTION MANUAL

One Jake Brown Road 

Old Bridge, NJ 08857-1000 USA 

(800) 523-6049 • (732) 679-4000 • FAX: (732) 679-4353

 

www.blondertongue.com

©2010 Blonder Tongue Laboratories, Inc.  All rights reserved.  Specifications are subject to change without notice.  Trademarks are the property of their respective owner.

AQC

 

Model                     Stock No. 

  Description

AQC 

6274 

Agile QAM Converter

Accessories

Model  

Stock No.  

Description

MIPS-12C  

7722C  

Power Supply

MIRC-12V  

7715  

Chassis

Status

Date

Document No.

Issue No.

Author

Active

February 12, 2010

651222900B

1

KK

Summary of Contents for MIPS-12C

Page 1: ...ries Inc All rights reserved Specifications are subject to change without notice Trademarks are the property of their respective owner AQC Model Stock No Description AQC 6274 Agile QAM Converter Accessories Model Stock No Description MIPS 12C 7722C Power Supply MIRC 12V 7715 Chassis Status Date Document No Issue No Author Active February 12 2010 651222900B 1 KK ...

Page 2: ...e Laboratories Inc One Jake Brown Road Old Bridge NJ 08857 Document Number USA 651222900B Printed in the United States of America All product names trade names or corporate names mentioned in this document are acknowledged to be the proprietary property of the registered owners This product incorporates copyright protection technology that is protected by U S patents and other intellectual propert...

Page 3: ...2c power supply 7 3 3 mips 12c power supply connections 7 SECTION 4 Specifications typical 8 4 1 mips 12c power supply specification 8 SECTION 5 installing the aqc 9 5 1 installing the aqc in a rack 9 SECTION 6 operating interface instructions 10 6 1 introduction 10 6 2 Main interactive sequence 10 6 3 programming a variable 10 6 4 rf out 10 6 5 output 10 6 6 output level 10 SECTION 7 appendix A c...

Page 4: ...structions before you operate the unit Retain all safety and operating instructions for future reference Heed all warnings on the unit and in the safety and operating instructions WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE NOTE TO CATV SYSTEM INSTALLER This reminder is provided to call the CATV System Installer s attention to Article 820 40 of the NEC that ...

Page 5: ...t protection For added protection during a lightning storm or when the unit is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the lines between the unit and the antenna This will prevent damage caused by lightning or power line surges Do not locate the antenna near overhead power lines or other electric light or power circuits or where it can fall...

Page 6: ...the module information The unitfeatures an advanced menu system based on a flash upgradable microcontroller this facilitates programming information to be easily entered with front panel accessible push button navigation switches 2 2 Features Modular Design Allows One to Six Single Upconverter Modules in Two Rack Spaces MIRC 12 MIPS 12 Fully Agile Output Frequency Range of 54 864 MHz Std HRC IRC a...

Page 7: ... ohm QAM RF Output 3 1 Front Panel Rear Panel Micro modulator Rack Chassis and Power Supply Units 3 2 MIRC 12V Chassis with MIPS 12C Power Supply 3 3 MIPS 12C Power Supply Connections All the connectors on the power supply are located on the rear panel 1 AC Input The power supply accepts standard 100 to 250 VAC inputs 2 DC Output The polarized D connector provides 12 sets of 12 Vdc 5 Vdc and groun...

Page 8: ...nd Noise 75 dBc min 40 dBmV Output 4 MHz BW Controls Connectors Liquid Crystal Display LCD 5 Interactive Navigation Enter Push Buttons IF Input F Type Female RF Output F Type Female Power Headers 3 Pin 5 12 VDC GND General Power Requirements Voltage 5 12 VDC Power Max 5 W Operating Temperature Range 0 to 50 C Humidity 0 to 90 RH Mechanical Dimensions 2 3 x 3 5 x 7 50 Inches 58 x 89 x 191mm Weight ...

Page 9: ...deep enclosed rack Secure the rack chassis front panel to the rack by inserting four machine screws with cup washers through the four mounting holes in the front panel When installing one or more chassis in a headend rack it is recommended to leave a 1 rack unit space 1 75 high between units to maximize air flow but it is not required This space helps to reduce heat build up in a headend rack and ...

Page 10: ...ent or decrement to the appropriate desired value 3 When the user reaches the desired setting the ENTER button is pressed again to save the change then the AQC module stores the new information 6 4 RF OUT The unit presents an up converted QAM RF output There are two modes that determine the upconversion programming NTSC The NTSC mode permits programming the RF output using a standard NTSC channel ...

Page 11: ... 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 327 333 339 345 351 357 363 369 375 381 387 393 399 405 411 417 423 429 435 441 447 453 459 465 471 477 483 489 495 501 507 513 519 525 531 537 543 549 555 561 567 573 579 585 EIA Chan Center Frequency MHz 85 86 87 88 89 90 91 92 93 94 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 ...

Page 12: ...ilable from BT on request VideoCipher DigiCipher are registered trademarks of Motorola Corp Rev 5 6 2009 Blonder Tongue Laboratories Inc Limited Warranty Blonder Tongue Laboratories Inc BT will at its sole option either repair or replace with a new or factory reconditioned product as BT may determine any product manufactured by BT which proves to be defective in materials or workmanship or fails t...

Reviews: