background image

Limited Warranty

For two (2) years from the date of purchase, Blue Angel will repair or replace, at its option, for the original
purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Blue
Angel to be defective in materials or workmanship.  Please call Blue Angel (1-888-636-6628) for instructions or
see your dealer.  Be prepared to provide the model number and serial number when exercising this warranty.
All transportation charges on Products or parts submitted for repair or replacement must be paid by
purchaser.

This Limited Warranty does NOT cover Products which have been damaged as a result of accident, abuse,
misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with Blue
Angel’s written instructions.

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO TWO YEARS FROM THE DATE OF PURCHASE.
THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL
DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED.

Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or
limitations of incidental or consequential damages, so the above limitations might not apply to you.  This
limited warranty gives you specific legal rights, and you may also have other legal rights which vary from state
to state.

In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall
Blue Angel or its suppliers be liable for any special, consequential, incidental or penal damages including, but
not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to
associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power,
downtime costs, or claims of buyer’s customers for such damages.

You 

MUST

retain your purchase receipt along with this form.  In the event you need to exercise a warranty

claim, you 

MUST

send a 

copy

of the purchase receipt along with the material or correspondence.  Please call

Blue Angel (1-888-636-6628) for return authorization and instructions.

DO NOT MAIL THIS FORM TO BLUE ANGEL.

Use this form only to maintain your records.

MODEL NO.  ____________________     

SERIAL NO.  ____________________

INSTALLATION DATE  ____________________

ATTACH YOUR RECEIPT HERE

Operating Instructions And Parts Manual

8

Description

The submersible pump is designed for
home applications. The unit is
equipped with a 3-prong grounding
type power cord. Motor is oil-filled and
sealed for cooler running and designed
to operate under water. This pump is
not suitable for aquatic life.

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return the
unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.

Important Safety
Instructions

READ AND FOLLOW ALL INSTRUCTIONS.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols: 

Operating Instruction and Parts Manual

BSE50, BSE75, BSE100, BSE200

332201-002 12/07

Danger indicates an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.

Warning

indicates a potentially hazardous
situation which, if not avoided, COULD
result in death or serious injury.

Caution indicates   a potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.

Notice indicates important information,
that if not followed, may cause
damage to equipment.

General Safety
Information

CALIFORNIA PROPOSITION 65

This product or its power cord may
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.

Sewer Ejector Pump

© 2007 Blue Angel™ Pumps

The Professional’s Line

Specifications

Power supply requirements

BSE50  . . . . . . . . . . . . . . . . . . . . . .120V, 60 hz
BSE75, BSE100, and BSE200  . . . .240V, 60 hz

Motor  . . . . . . . . . . . . . . . . . . . . . . .Single phase, oil filled
Horsepower/Current

BSE50  . . . . . . . . . . . . . . . . . . . . . .1/2 HP, 12 A
BSE75  . . . . . . . . . . . . . . . . . . . . . .3/4 HP, 7 A
BSE100  . . . . . . . . . . . . . . . . . . . . .1 HP, 8.5 A
BSE200  . . . . . . . . . . . . . . . . . . . . .2 HP, 12 A

Liquid temperature range  . . . . . .40°F to 120°F
Circuit requirements  . . . . . . . . . . .15 amps (min)
Dimensions . . . . . . . . . . . . . . . . . . .11

1

/

2

” high x 9

3

/

4

” base

Cut-in level (factory set)  . . . . . . . .13”
Cut-out level (factory set)  . . . . . . .7”

Construction

Motor housing  . . . . . . . . . . . .Cast Iron

Volute  . . . . . . . . . . . . . . . . . . .Cast Iron

Impeller . . . . . . . . . . . . . . . . . .Glass reinforced thermoplastic

Shaft  . . . . . . . . . . . . . . . . . . . .Low carbon steel

Seals  . . . . . . . . . . . . . . . . . . . .Buna N

Discharge  . . . . . . . . . . . . . . . .1

1

/

2

” NPT

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

Please read and save these instructions. Read carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by
observing all safety information. Failure to comply with instructions could result in
personal injury and/or property damage! Retain instructions for future reference.

GENERAL SAFETY INFORMATION

Do not use to pump
flammable or explosive
fluids such as gasoline, fuel
oil, kerosene, etc. Do not use
in a flammable and/or explosive
atmosphere. Pump should only be used
to pump clear water. Personal injury
and/or property damage could result.

This pump is not designed to handle salt
water, brine, laundry discharge or any
other application which may contain
caustic chemicals and/or foreign materials.
Pump damage could occur if used in these
applications and will void warranty.

All wiring must be performed by a
qualified electrician.

If the basement has water or
moisture on the floor, do not
walk on wet area until all
power is turned off. If the shut-off box
is in the basement, call an electrician.
Remove pump and either repair or
replace. Failure to follow this warning
could result in fatal electrical shock.

For parts, product & service information

visit 

www.blueangelpumps.com

www.blueangelpumps.com

Reviews: